ECHO CONSTRUCTION AND REMODELING INC. | B= | C | 07/02/2021 | All other required Final inspections are complete. (This is a computer generated result) | TRENTP | TRENTP | | B= | C | 7023331 |
ECHO CONSTRUCTION AND REMODELING INC. | B= | P | 06/22/2021 | Previous items corrected. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 7011111 |
ECHO CONSTRUCTION AND REMODELING INC. | B= | P | 06/22/2021 | Temp CO: Need health and building ( Expires: 7/22/2021 12:00:00 AM) | JANE | JANE | | B= | P | 7010735 |
ECHO CONSTRUCTION AND REMODELING INC. | B= | P | 06/22/2021 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / Pending field inspection of other corrections -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 7010228 |
ECHO CONSTRUCTION AND REMODELING INC. | BSP | P | 06/21/2021 | New landing plans have been spliced and landing has been built per plan, pier sizes match plans / | ERIKK | ERIKK | | BSP | P | 7009323 |
ECHO CONSTRUCTION AND REMODELING INC. | BFT | P | 06/16/2021 | Need to splice new landing into plans to confirm approved pier dimensions and framing when built / Inspector observed (2) 10x36 inch piers | TRENTP | TRENTP | | BFT | P | 7004680 |
ECHO CONSTRUCTION AND REMODELING INC. | B= | R | 06/11/2021 | Need to provide air leakage test results / Missing 36 inch landing outside of main egress door / Need to provide attic access to inspect attic insulation / Crawlspace, no deck, no AC. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 7000276 |
ECHO CONSTRUCTION AND REMODELING INC. | BIN | C | 04/08/2021 | Installers certificate for blown in insulation on file | TRENTP | TRENTP | | BIN | C | 6926108 |
ECHO CONSTRUCTION AND REMODELING INC. | BIN | P | 04/07/2021 | Need to provide installers certificate for blown in insulation in walls, inspector observed 7 1/2 inches in walls / Will inspect attic and crawlspace insulation at final / Need to provide Air Leakage Testing results Per 2015 IECC Section R402.4.1.2 by Final Inspection / | TRENTP | TRENTP | | BIN | P | 6925186 |
ECHO CONSTRUCTION AND REMODELING INC. | BFR | C | 04/06/2021 | Photo of correction on file | CHAD | CHAD | | BFR | C | 6922899 |
ECHO CONSTRUCTION AND REMODELING INC. | BFR | P | 04/02/2021 | Need to secure stair stringers, will accept photos of correction attached to inspection request / Rest of interior framing okay / See previous permit for structural framing / Crawlspace, no deck | TRENTP | TRENTP | | BFR | P | 6920474 |
GLENN WILSON ELECTRIC INC | E= | C | 06/03/2021 | E= OK ---- NO A/C ---- | GREGM | GREGM | | E= | C | 6989890 |
GLENN WILSON ELECTRIC INC | ES | C | 06/03/2021 | Residential Underground: 200-amp 3 Wire New Residence ok need meter seal. / | GREGM | GREGM | | ES | C | 6989883 |
GLENN WILSON ELECTRIC INC | ER | C | 03/19/2021 | 1 - #6 , 1 - #8 , 1 - #10 , ufer is not irreversible , no mcc , no central vac | TOMC | TOMC | | ER | C | 6905596 |
ADVANTAGE HEATING AND COOLING | H= | C | 06/10/2021 | PER E-MAIL PPRBD WILL NOT CONSIDER A SINGLE PENETRATION THROUGH AN EXISTING ENVELOPE ASSEMBLY AS AN ALTERATION TO THAT ASSEMBLY. 6" HIGH COMBUSTION AIR IS OK, NO INSULATION REQUIRED / WHOLE HOUSE VENT FAN LABELED IN LAUNDRY ROOM AND ON SEPARATE SWITCH FROM LIGHT / | ANGELW | ANGELW | | H= | C | 6997874 |
ADVANTAGE HEATING AND COOLING | H= | P | 06/04/2021 | REFER TO THE 2015 IECC R 402.4.4 FOR ROOMS CONTAINING FUEL BURNING APPLIANCES (BECAUSE OF THE 6'' ROUND HIGH COMBUSTION AIR AND DRAFT HOOD WATER HEATER, WHICH IS COMPLETELY ACCEPTABLE PROVIDED ALL REQUIREMENTS OF THAT SECTION ARE MET. STILL NEED THE DUCT LEAKAGE REPORT, THE WHOLE HOUSE VENTILATION SWITCH CANNOT BE TIED IN WITH THE LIGHT SWITCH, NOTE / CONDITIONED CRAWL SPACE / DIRECT VENT FURNACE / NO OUTSIDE AIR TO FURNACE RETURN / NO A/C / | TREVORH | TREVORH | | H= | P | 6991706 |
ADVANTAGE HEATING AND COOLING | H= | P | 05/14/2021 | MISSING MASTER BATH FAN FOR THE SHOWER AREA / INSTALL RETURN AIR PATH FOR THE MASTER BEDROOM / WHOLE HOUSE FAN SWITCH NEEDS TO BE LABELED / WHOLE HOUSE FAN NEEDS TO TURN OFF AND ON COMPLETELY / COMPLETE THE EXHAUST VENTING FOR THE MICROWAVE / MECHANICAL ROOM LACKS COMBUSTION AIR, PROVIDE HI-LOW GRILLES FROM THE HOUSE TO THE MECHANICAL ROOM / Whole house ventilation being achieved with exhaust fan located in laundry room. / Unable to locate whole house ventilation switch / NOTE / CONDITIONED CRAWL SPACE / DIRECT VENT FURNACE / NO OUTSIDE AIR TO FURNACE RETURN / NO A/C / | SAMS | SAMS | | H= | P | 6969388 |
ADVANTAGE HEATING AND COOLING | HC | C | 03/30/2021 | RELEASE METER | SAMS | SAMS | | HC | C | 6915227 |
ADVANTAGE HEATING AND COOLING | HRR | C | 03/30/2021 | PROVIDE DUCT LEAKAGE REPORT BY FINAL | SAMS | SAMS | | HRR | C | 6915216 |
R AND D PLUMBING | HI | C | 03/24/2021 | BY FINAL SUPPORT 1 INCH MAIN IN CRAWL SPACE EVERY 8 FEET PER TABLE G2424.1 AND INSTALL GAS SHUT OFF AT RANGE. 10 LB TEST OK / 1 FURNACE / 1 WATER HEATER / 1 RANGE / | NANCY | NANCY | | HI | C | 6909346 |
ADVANTAGE HEATING AND COOLING | HRR | R | 03/19/2021 | TRIP FEE WAIVED. CONTRACTOR TO COMPLETE ALL WORK BEFORE REQUESTING NEXT INSPECTION. PROPERLY TERMINATE FURNACE VENTING (SEE INSTALLATION INSTRUCTIONS PAGE #38 FIGURE #46 FOR INSIDE CORNER VENT TERMINATIONS AND OPERABLE WINDOWS), INSTALL DRYER EXHAUST, INSTALL WATER HEATER VENTING, INSULATE ROUND SUPPLY AIR PIPING IN ATTIC. COMBUSTION AIR FOR WATER HEATER? MISSING WHOLE HOUSE VENTILATION FAN AT LAUNDRY ROOM. BY FINAL: NEED DUCT LEAKAGE REPORT. NOTE / CONDITIONED CRAWLSPACE / DIRECT VENT FURNACE / NO A/C / NO OUTSIDE AIR TO FURNACE RETURN / | BILLS | BILLS | | HRR | R | 6904946 |
R AND D PLUMBING | P= | C | 05/26/2021 | | JOSEPHD | JOSEPHD | | P= | C | 6981611 |
HOMEOWNER | PWO | C | 05/26/2021 | note: pre-existing well | JOSEPHD | JOSEPHD | | PWO | C | 6981610 |
R AND D PLUMBING | P= | P | 05/25/2021 | need to remove cap from vent on roof, need pwo inspection for water line run to existing well, rest ok | JOSEPHD | JOSEPHD | | P= | P | 6980238 |
R AND D PLUMBING | PTO | C | 03/23/2021 | note: need pwo inspection, no irrigation, by final need freeze protection in water heater closet, need backwater at hub drain in crawlspace, aav @ washer box, master lav, hall lav, upstairs hall closet, vtr 1 | JOSEPHD | JOSEPHD | | PTO | C | 6907603 |
ECHO CONSTRUCTION AND REMODELING INC. | XBS | P | 06/17/2021 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: Porch framing | SHELLEY | SHELLEY | | XBS | P | 7006070 |