HOMEOWNER | B= | C | 09/08/2022 | Items corrected | RYANF | RYANF | | B= | C | 7510131 |
HOMEOWNER | B= | P | 09/07/2022 | Photos of down spouts received need site inspection to complete -- Schedule a new Building Final when above items are complete. | GREGT | GREGT | | B= | P | 7507965 |
HOMEOWNER | B= | P | 06/22/2022 | Missing gutters, downspouts, and tip outs throughout / Stucco incomplete at west side at each side of bay window causing exposure / Rest okay -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 7420523 |
HOMEOWNER | BFN | C | 06/17/2022 | BFD complete | TRENTP | TRENTP | | BFN | C | 7414882 |
HOMEOWNER | BFT | C | 05/25/2022 | Drain items complete | PAULP | PAULP | | BFT | C | 7388016 |
HOMEOWNER | BIN | C | 05/25/2022 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | PAULP | PAULP | | BIN | C | 7388007 |
HOMEOWNER | BFR | C | 05/24/2022 | BFD complete | TRENTP | TRENTP | | BFR | C | 7386316 |
HOMEOWNER | BFD | C | 05/24/2022 | Engineer letter for perimeter drain on file | TRENTP | TRENTP | | BFD | C | 7386310 |
HOMEOWNER | BFD | R | 05/23/2022 | Inspection note states paperwork upload, no attachments on request / Image upload requested. If unfamiliar with uploading images for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | TRENTP | TRENTP | | BFD | R | 7385064 |
HOMEOWNER | BFR | P | 05/17/2022 | Still need to complete BFD / Field copy of drain installation on file | TRENTP | TRENTP | | BFR | P | 7378195 |
HOMEOWNER | BFD | P | 05/17/2022 | Need to provide licensed design professional stamped copy of drain observation / Field copy of drain installation on file | TRENTP | TRENTP | | BFD | P | 7378193 |
TUFF SHED INC | BIN | R | 02/22/2022 | Need to complete foundation inspections and BFR / Need Air Leakage Testing results Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection | TRENTP | TRENTP | | BIN | R | 7278633 |
TUFF SHED INC | BSP | P | 02/22/2022 | Changed to BSP / Installers certificate and evaluation reports for spray foam insulation on file | TRENTP | TRENTP | | BSP | P | 7277135 |
TUFF SHED INC | BFR | R | 01/28/2022 | frame OK pending completion of foundation inspections | LONNYS | LONNYS | | BFR | R | 7253673 |
TUFF SHED INC | BFD | P | 01/28/2022 | Engineer letter requiring perimeter drain at usable crawlspace area and drain detail on file -- Will need to either inspect perimeter drain or provide 3rd party observation for perimeter drain | DAKOTAB | DAKOTAB | | BFD | P | 7253296 |
TUFF SHED INC | BFT | P | 01/20/2022 | Spoke on phone with tuff shed rep, Still need revised open hole stating whether perimeter drain around crawlspace is required as stated in the soils report to complete foundation inspections -- If perimeter drain is still required, will also need a drain detail, explaining how drain is to be built | DAKOTAB | DAKOTAB | | BFT | P | 7245563 |
TUFF SHED INC | BFR | R | 01/18/2022 | 1. Complete all foudnation inspections. 2. Missing roof boot for dry in. 3. Header at landing on main level needs to be 6'4". 4. Missing LS30's at CG01 to HG01 on each end. 5. Nuts and washer missing on multiple anchor bolts and missing within 12" of plate breaks on entire main level.
| ERIKK | ERIKK | | BFR | R | 7242483 |
TUFF SHED INC | BIN | P | 01/17/2022 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 7240591 |
TUFF SHED INC | BFI | C | 01/04/2022 | | JASONB | JASONB | | BFI | C | 7228473 |
TUFF SHED INC | BLA | C | 11/18/2021 | Lath okay / Note: Side cover and pop out roof framing has not been inspected, side posts and popout roof framing covered at time of lath inspection | TRENTP | TRENTP | | BLA | C | 7182624 |
TUFF SHED INC | BFI | R | 10/27/2021 | IECC form in plans show R10 to be installed @ 24 inches around thermal envelope, inspector only observed R10 @ 12 inches around the 3 exterior walls of dwelling / Inspector unable to confirm foundation insulation at slab between unheated garage and dwelling | TRENTP | TRENTP | | BFI | R | 7156950 |
TUFF SHED INC | BSP | P | 10/12/2021 | foundation design and soils on file / still need updated open hole per notes from previous inspection | LONNYS | LONNYS | | BSP | P | 7137860 |
TUFF SHED INC | BSP | P | 10/11/2021 | 6" and 12" nailing per plan | CHRISTYB | CHRISTYB | | BSP | P | 7137779 |
TUFF SHED INC | BFN | P | 08/09/2021 | Open hole on file 1500 psf / UPDATE 8/25/21 DRS changed to partial because foundation design stamp is not signed. Spoke on phone with Travis of Tuff Shed and discussed need for stamped and signed design and need for design for frost protection and need for drain at crawl space per the soils report and need for open hole to address the soils report address and drain requirements. | TRENTP | TRENTP | | BFN | P | 7064378 |
TUFF SHED INC | BFT | P | 08/09/2021 | Inspection changed to BFT / Open hole on file, 1500 psf / UPDATE 8/25/21 DRS changed to partial because foundation design stamp is not signed. Spoke on phone with Travis of Tuff Shed and discussed need for stamped and signed design and need for design for frost protection and need for drain at crawl space per the soils report and need for open hole to address the soils report address and drain requirements. | TRENTP | TRENTP | | BFT | P | 7064375 |
TUFF SHED INC | BFN | P | 06/23/2021 | Still need to provide open hole / Soils report on file | TRENTP | TRENTP | | BFN | P | 7012023 |
TUFF SHED INC | BFT | P | 04/30/2021 | Still need to provide copies of soils report and open hole to permit electronically / Re enforcement for footings forms and interior pad okay per plan / Bearing capacity of foundation design still to be confirmed with reports, pour at own risk / Image upload requested. If unfamiliar with uploading images for an inspection, please use the following link: https://youtu.be/QS0hdGSBA6o / | TRENTP | TRENTP | | BFT | P | 6953894 |
TUFF SHED INC | BFT | P | 04/26/2021 | provide open hole and soils / middle crawler wall forms and reinforcing OK only / still need to inspect mono slab forms and reinforcing when ready / pour walls at own risk pending soils foundation design on file 1500PSF | LONNYS | LONNYS | | BFT | P | 6946648 |
NATIVE ELECTRICAL CONTRACTORS LTD | E= | C | 06/13/2022 | | TOMC | TOMC | | E= | C | 7409209 |
NATIVE ELECTRICAL CONTRACTORS LTD | ES | C | 06/13/2022 | Residential Underground: 200-amp 3-wire service upgrade, no action required by utility. / | TOMC | TOMC | | ES | C | 7409208 |
NATIVE ELECTRICAL CONTRACTORS LTD | ER | C | 01/13/2022 | ER COMPLETED 12/23/21 ------ | GREGM | GREGM | | ER | C | 7238605 |
NATIVE ELECTRICAL CONTRACTORS LTD | ER | C | 12/23/2021 | ER OK --- #6CU HOT TUB --- #8CU A/C --- #8AL RANGE W/H ----- NO MCC ---- | GREGM | GREGM | | ER | C | 7238596 |
HOMEOWNER | H= | C | 06/22/2022 | Corrections made, see images / | CASEYM | CASEYM | | H= | C | 7420186 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 06/16/2022 | Label whole house ventilation switch / Remove screen from dryer exhaust termination / Ok to send pictures with next inspection request / Whole house ventilation being achieved through exhaust fan located in bathroom / Whole house ventilation switch located in bathroom / NOTE / House is heated and cooled with mini splits, 2 heads on main floor and 2 on upper level / Electric water heater | CASEYM | CASEYM | | H= | P | 7414573 |
HEATING & PLUMBING ENGINEERS, INC | HI | C | 01/11/2022 | NO GAS IN HOUSE ELECTRIC FOR EVERYTHING | NICKE | NICKE | | HI | C | 7234671 |
HEATING & PLUMBING ENGINEERS, INC | HRR | C | 01/10/2022 | HOUSE IS BEING HEATED AND COOLED USING MINI SPLITS. 2 HEADS ON MAIN FLOOR 2 HEADS ON UPPER FLOOR (MASTER BEDROOM) WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN MASTER BATHROOM / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / ELECTRIC WATER HEATER / | NICKE | NICKE | | HRR | C | 7234097 |
MD SERVICE PLUMBING, INC. | P= | C | 06/14/2022 | HAS PVB FOR IRRIGATION -- R.P. INSTALLED FOR YARD HYDRANTS -- POTABLE WATER CERT. IN IMAGES | LEE | LEE | | P= | C | 7410611 |
HOMEOWNER | P= | C | 06/14/2022 | FOR POTABLE H20 CERT. | LEE | LEE | | P= | C | 7410592 |
MD SERVICE PLUMBING, INC. | PTO | C | 12/30/2021 | permit corrected | JOSEPHD | JOSEPHD | | PTO | C | 7222869 |
MD SERVICE PLUMBING, INC. | PTO | P | 12/28/2021 | still need to be on correct permit can complete pto once that is done, other corrections made see images, note: check for RP for yard hydrant at P= | JOSEPHD | JOSEPHD | | PTO | P | 7221231 |
MD SERVICE PLUMBING, INC. | PTO | P | 12/23/2021 | need to attach this to permit #N38668, lacking 10 times pipe diameter down stream to next horizontal branch at 3" stack, need freeze protection at p-trap in garage, rest ok note: check electric water heater at final, aav @ washer box, kitchen sink, utility sink, vtr 1 | JOSEPHD | JOSEPHD | | PTO | P | 7221230 |
MD SERVICE PLUMBING, INC. | P= | R | 04/26/2021 | not ready for final | JOSEPHD | JOSEPHD | | P= | R | 6946396 |
MD SERVICE PLUMBING, INC. | P= | R | 04/26/2021 | this is not a potable water certification | JOSEPHD | JOSEPHD | | P= | R | 6946193 |
MD SERVICE PLUMBING, INC. | PWO | C | 04/08/2021 | will need potable water certification by final, 1 line from well into structure, 1 line out from structure to 2 yard hydrants will need backflow by final | JOSEPHD | JOSEPHD | | PWO | C | 6926558 |