GOEBEL CONSTRUCTION, INC | B= | C | 11/17/2021 | Items corrected | TRENTP | TRENTP | | B= | C | 7180076 |
GOEBEL CONSTRUCTION, INC | BSP | P | 11/17/2021 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | BSP | P | 7179789 |
GOEBEL CONSTRUCTION, INC | BIN | C | 11/17/2021 | Changed to BIN / Blown in insulation certificate on file | TRENTP | TRENTP | | BIN | C | 7179766 |
GOEBEL CONSTRUCTION, INC | B= | R | 11/16/2021 | Need to complete BIN and provide test report for product used for fire protection of floors / Missing handrail at garage stairs to main house / Bath fan does not work in master bathroom / Finished basement, rear deck w/out stairs, AC | TRENTP | TRENTP | | B= | R | 7178927 |
GOEBEL CONSTRUCTION, INC | BSP | P | 11/16/2021 | Changed to BSP / Still need to provide test report for product used for fire protection of floors / Installers certificate for no burn already on file / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / NOTE: Still need to provide blown in installers certificate to complete BIN | TRENTP | TRENTP | | BSP | P | 7177962 |
GOEBEL CONSTRUCTION, INC | BSP | R | 11/08/2021 | Paperwork provided to be submitted to mechanical inspector on mechanical inspection request | TRENTP | TRENTP | | BSP | R | 7168214 |
GOEBEL CONSTRUCTION, INC | BLA | C | 08/25/2021 | Lath ok / | ERIKK | ERIKK | | BLA | C | 7084994 |
GOEBEL CONSTRUCTION, INC | BFR | C | 08/06/2021 | Rear deck ledger corrected / Note: Still need to provide Test report for materials used for fire protection of floor per IRC 302.13 EX #4 by final | TRENTP | TRENTP | | BFR | C | 7063744 |
GOEBEL CONSTRUCTION, INC | BFR | P | 08/06/2021 | Provide Test report for materials used for fire protection of floor per IRC 302.13 EX #4, installers certificate on file / Pending field inspection of other corrections | TRENTP | TRENTP | | BFR | P | 7062834 |
GOEBEL CONSTRUCTION, INC | BIN | P | 08/05/2021 | Need to complete BFR / Need to provide installers certificate for blown in insulation, observed 5 1/2 inches in exterior walls / Will inspect attic insulation at final, need air leakage test results by final | TRENTP | TRENTP | | BIN | P | 7062205 |
GOEBEL CONSTRUCTION, INC | BFR | P | 08/05/2021 | Incorrect deck ledger fastening per plan / Rest of items okay | TRENTP | TRENTP | | BFR | P | 7062201 |
GOEBEL CONSTRUCTION, INC | BSP | P | 08/05/2021 | Engineer letter for anchor bolt observation on file | TRENTP | TRENTP | | BSP | P | 7061402 |
GOEBEL CONSTRUCTION, INC | BFR | P | 08/02/2021 | Missing bearing blocking at AO3 in garage / Missing VCTR clips at mother in law suite over framing / Over notch top plate at both dryer vents in mother in law and main house / Need to secure mono post in beam pockets / Unable to confirm anchor bolts in basement or rear wall of garage / Provide Test report and installers certificate for materials used for fire protection of floor per IRC 302.13 EX #4 / Will inspect trusses and rear deck at re inspection / Finished basement, rear deck | TRENTP | TRENTP | | BFR | P | 7057639 |
GOEBEL CONSTRUCTION, INC | BSP | P | 08/02/2021 | Engineer observation of water heater platform framing on file | TRENTP | TRENTP | | BSP | P | 7056545 |
GOEBEL CONSTRUCTION, INC | BSP | L | 07/30/2021 | Inspection changed to BSP / Cancelled by contractor (Marv) | TRENTP | TRENTP | | BSP | L | 7054871 |
GOEBEL CONSTRUCTION, INC | BSP | R | 07/29/2021 | Inspection changed to BSP and stopped after too many items / Will need full re inspection | TRENTP | TRENTP | | BSP | R | 7054241 |
GOEBEL CONSTRUCTION, INC | BSP | P | 06/14/2021 | Unable to confirm 2x2 inch washers at anchor bolts for narrow braced wall, will accept photos of correction uploaded to inspection request or can inspect at BFR / Front, rear, and side porch framing okay | TRENTP | TRENTP | | BSP | P | 7001456 |
GOEBEL CONSTRUCTION, INC | BSP | P | 06/14/2021 | Foundation design already on file, pend inspection of request comments | TRENTP | TRENTP | | BSP | P | 7000584 |
GOEBEL CONSTRUCTION, INC | BSP | P | 05/07/2021 | rear deck piers OK | LONNYS | LONNYS | | BSP | P | 6961251 |
GOEBEL CONSTRUCTION, INC | BSP | P | 05/07/2021 | Duplicate copy of foundation design on file / Pending field inspection for exterior piers | TRENTP | TRENTP | | BSP | P | 6960623 |
GOEBEL CONSTRUCTION, INC | BFD | C | 04/23/2021 | Drain around usable to day light at west side, dampproofing okay / Note: Need to complete BFN | TRENTP | TRENTP | | BFD | C | 6945651 |
GOEBEL CONSTRUCTION, INC | BFI | C | 04/23/2021 | R13 installed / Note: Need to complete BFN | TRENTP | TRENTP | | BFI | C | 6945649 |
GOEBEL CONSTRUCTION, INC | BFN | P | 04/23/2021 | Exterior piers were not inspected per engineer observation for footing/foundation, will need to provide engineer observation or request inspection / Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | P | 6944681 |
GOEBEL CONSTRUCTION, INC | BFT | C | 04/23/2021 | open hole on file -- 3000 PSF -- usable -- 5% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / Note: Exterior piers were not inspected per engineer observation | TRENTP | TRENTP | | BFT | C | 6944677 |
GOEBEL CONSTRUCTION, INC | BFI | P | 04/23/2021 | Foundation design on file / Pending field inspection | TRENTP | TRENTP | | BFI | P | 6944673 |
GOEBEL CONSTRUCTION, INC | BFD | P | 04/23/2021 | Open hole, soils report, and footing/foundation observation on file / Pending field inspection | TRENTP | TRENTP | | BFD | P | 6944667 |
A N' M ELECTRIC | E= | C | 10/27/2021 | 3 - 30 amp a/c , hot-tub , steamer | TOMC | TOMC | | E= | C | 7156184 |
A N' M ELECTRIC | ES | C | 07/26/2021 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 7048949 |
A N' M ELECTRIC | ER | C | 07/26/2021 | 2 - 250 SER ,1 - # 2 SER , 1 - # 2 future out bldg , 9 - # 6 SER , 1 - # 10 , irreversible ufer , finished basement | TOMC | TOMC | | ER | C | 7048942 |
A N' M ELECTRIC | EP | C | 07/26/2021 | 2 - 200 amp sub-panels , | TOMC | TOMC | | EP | C | 7048924 |
A N' M ELECTRIC | EUG | C | 07/09/2021 | 500 urd x 2 | TOMC | TOMC | | EUG | C | 7030002 |
CUSTOM CLIMATE CONTROL | H= | C | 11/08/2021 | | JHORSMAN | JHORSMAN | | H= | C | 7168280 |
CUSTOM CLIMATE CONTROL | H= | P | 11/04/2021 | STILL NEED 2 LB APPROVAL LETTER FROM GAS PROVIDER BEFORE H= CAN BE COMPLETE. ONCE 2 LB LETTER IS RECEIVED H= CAN BE COMPLETED WITH NO ON SITE INSPECTION REQUIRED | JHORSMAN | JHORSMAN | | H= | P | 7165333 |
CUSTOM CLIMATE CONTROL | H= | P | 11/04/2021 | EQUIPMENT CHANGE LETTER RECEIVED, SEE IMAGES | JHORSMAN | JHORSMAN | | H= | P | 7164993 |
CUSTOM CLIMATE CONTROL | H= | P | 10/28/2021 | REQUIRED FOR FINAL: EQUIPMENT CHANGE FORM FOR INDOOR COIL FOR MAIN LEVEL SYSTEM / CONTRACTOR TO ADDRESS THE FOLLOWING: PROVIDE 6" CLEARANCE FROM SINGLE WALL B VENT CONNECTOR TO COMBUSTIBLE MATERIALS IN GUEST HOUSE WATER HEATER CLOSET (IN GARAGE) / Whole House Ventilation being achieved with exhaust fan located in laundry room in main house / Whole House Ventilation Switch located in laundry room / NOTES / MAIN HOUSE - A/C COMPLETE / 1 A/C LINESET INTO MAIN MECHANICAL ROOM / OUTSIDE AIR TO FURNACE RETURN / FINISHED BASEMENT / LOUVER DOOR INTO MAIN MECHANICAL ROOM / DIRECT VENT FURNACE X2 / GUEST HOUSE - A/C COMPLETE / NO OUTSIDE AIR TO FURNACE RETURN / CONDITIONED CRAWL SPACE / DIRECT VENT FURNACE IN CRAWL SPACE / HIGH LOW GRILLS INTO WATER HEATER CLOSET IN GUEST HOUSE GARAGE / | ANGELW | ANGELW | | H= | P | 7158068 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 07/28/2021 | 2- MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | DUSTINS | DUSTINS | | HV | C | 7051799 |
DAVIS GAS SHOP INC | HC | C | 07/27/2021 | RELEASE 2LB METER | JHORSMAN | JHORSMAN | | HC | C | 7051356 |
DAVIS GAS SHOP INC | HI | C | 07/27/2021 | BY FINAL PROVIDE 2 LB APPROVAL LETTER/ 1 INCH MAIN /CSST INSTALLED OFF MAIN/ 3 FURNACES / 3 WATER HEATERS / 1 RANGE / 2 FIREPLACES / 1 BBQ STUB OUT UPPER PATIO GOOD FOR UP TO 40 K BTUS/ 1 BBQ STUB OUT BASEMENT PATIO GOOD FOR UP TO 40K BTUS / | JHORSMAN | JHORSMAN | | HI | C | 7051349 |
CUSTOM CLIMATE CONTROL | HRR | C | 07/27/2021 | | JHORSMAN | JHORSMAN | | HRR | C | 7051348 |
DAVIS GAS SHOP INC | HI | P | 07/26/2021 | PROVIDE 2 LB APPROVAL LETTER BY FINAL/ WHAT WERE THE CALCULATED BTU'S FOR THE BBQ STUBS?/ 10 LB TEST OK / 1 INCH MAIN /CSST INSTALLED OFF MAIN/ 3 FURNACES / 3 WATER HEATERS / 1 RANGE / 2 FIREPLACES / 2 BBQ STUBS / | JHORSMAN | JHORSMAN | | HI | P | 7049468 |
CUSTOM CLIMATE CONTROL | HRR | P | 07/23/2021 | COIL INSTALLED FOR MAIN LEVEL SYSTEM DOES NOT MATCH EQUIPMENT LISTED ON APPROVED DUCT DESIGN / CONTRACTOR MUST FILL OUT THE EQUIPMENT CHANGE FORM (RESIDENTIAL) AND ATTACH FORM TO AN INSPECTION REQUEST BY FINAL / HIGH/ LOW GRILLS FOR GARAGE WATER HEATER ARE UNDERSIZED AFTER 25 PERCENT REDUCTION/ PROPERLY SUPPORT FURNACE VENTING EVERY 4 FEET PER PAGE 46 NUMBER 2 OF INSTALLATION MANUAL/ Whole house ventilation being achieved through exhaust fan located in mud room and exhaust fan located in laundry room. / Verify whole house ventilation switch location at final / NOTE / CONDITIONED CRAWL SPACE FOR GUEST HOUSE / FINISHED BASEMENT / DIRECT VENT FURNACE X3 / A/C ROUGH, COIL AND LINESET X2 (MAIN LEVEL AND GUEST HOUSE) / A/C ROUGH, LINESET ONLY LOWER LEVEL SYSTEM / | JHORSMAN | JHORSMAN | | HRR | P | 7046993 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 07/08/2021 | PAGE 14 REFERENCES A 39'' DIMENSION FREE OF COMBUSTIBLES ABOVE FIRE PLACE MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | TREVORH | TREVORH | | HV | P | 7028991 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 11/09/2021 | | JOSEPHD | JOSEPHD | | P= | C | 7170159 |
PACIFIC PLUMBING, INCORPORATED | P= | P | 11/09/2021 | photo of backwater valve in crawlspace in image | JOSEPHD | JOSEPHD | | P= | P | 7169668 |
PACIFIC PLUMBING, INCORPORATED | P= | P | 11/08/2021 | need access to crawlspace guest side of house to check backwater valve, need installation instruction for steam unit and need air gap at steam t&p, and drain down, tub crossed in basement bathroom with double lavs, rest ok note: finished basement, pvb installed | JOSEPHD | JOSEPHD | | P= | P | 7168622 |
PACIFIC PLUMBING, INCORPORATED | P= | P | 11/08/2021 | potable water certification in images | JOSEPHD | JOSEPHD | | P= | P | 7168094 |
HOMEOWNER | PWO | C | 08/13/2021 | correction made verified electronically | JOSEPHD | JOSEPHD | | PWO | C | 7071094 |
PACIFIC PLUMBING, INCORPORATED | PWO | R | 08/12/2021 | need to uncover water line run between the 2 side of house to verify depth, can not see what size sleeve thru wall is, water line connected to potable water in mech room ok | JOSEPHD | JOSEPHD | | PWO | R | 7070389 |
PACIFIC PLUMBING, INCORPORATED | PWO | P | 08/10/2021 | can not feed mother in-law side from non-potable water to irrigation in mech room, still need to see pipe run from main side of house over to mother in- law side | JOSEPHD | JOSEPHD | | PWO | P | 7066246 |
HOMEOWNER | PWO | P | 08/06/2021 | still need to see how water line is being run to mother in-law side of house, rest ok note: will need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | P | 7063435 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 07/23/2021 | will still need pwo inspection, note: contractor stated that there would be electric heater in water heater closet for freeze protection check at final | JOSEPHD | JOSEPHD | | PTO | C | 7046501 |
PACIFIC PLUMBING, INCORPORATED | PTO | P | 07/19/2021 | how is the water heater closet being heated on mother in-law side?, still need to see water line stubbed in to both side of house, and sewer stub on mother in-law side, rest ok note: mother in-law side = check KC trap for backwater at final, vtr 2, RP in main side mech room is for irrigation, check steam unit clearances at final on main side | JOSEPHD | JOSEPHD | | PTO | P | 7040083 |
PACIFIC PLUMBING, INCORPORATED | PTO | P | 07/09/2021 | for main house side only, still need mother in-law side pto, is the RP for irrigation? is there a steam unit being installed? still need water line stubbed in and pwo inspection, rest ok north side of house ok, note: finished basement, aav @ wet bar, basement lav by stairs, back side of spa in wall, | JOSEPHD | JOSEPHD | | PTO | P | 7030779 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 05/03/2021 | no water in at this time | JOSEPHD | JOSEPHD | | PB | C | 6954984 |