HOMEOWNER | B= | C | 09/30/2022 | Items corrected / Requested paperwork received on site | TRENTP | TRENTP | | B= | C | 7536400 |
HOMEOWNER | BIN | C | 09/30/2022 | Evaluation report for thermal barrier on file | TRENTP | TRENTP | | BIN | C | 7535472 |
HOMEOWNER | B= | R | 09/28/2022 | Need to complete BIN / Hand rails at interior are not graspable per code / Need to provide manufactures clarification if foundation foam requires protection / Handrail at rear deck is not continuous / Provide product test report and installers certificate for material used in fire protection of floors per IRC 302.13 EX #4 / Unfinished basement, rear deck w/stairs, AC | TRENTP | TRENTP | | B= | R | 7533401 |
HOMEOWNER | BIN | P | 09/28/2022 | Changed to BIN for image upload / Need to provide evaluation report for thermal barrier / Installers certificate for thermal barrier on file / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BIN | P | 7532229 |
HOMEOWNER | BSP | P | 07/21/2022 | Front porch footing okay | TRENTP | TRENTP | | BSP | P | 7455191 |
HOMEOWNER | BIN | P | 07/06/2022 | Still need to provide installers certificate and evaluation report for thermal barrier at spray foam, install cert provided does not note the installation of thermal barrier / Photos of floor insulation on file | TRENTP | TRENTP | | BIN | P | 7435636 |
HOMEOWNER | BIN | P | 06/14/2022 | Need to insulation floor over rear deck, will accept photos attached to inspection with R value depicted / Need to provide installers certificate and evaluation report for thermal barrier used on spray foam insulation / Will inspect attic insulation at final / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | TRENTP | TRENTP | | BIN | P | 7410954 |
HOMEOWNER | BFR | C | 06/14/2022 | Items okay / Note: Still need to observe front porch post as BSP when ready | TRENTP | TRENTP | | BFR | C | 7410946 |
HOMEOWNER | BFI | C | 06/14/2022 | R12.5 Superior walls throughout per engineer letter on file | TRENTP | TRENTP | | BFI | C | 7410938 |
HOMEOWNER | BIN | P | 06/14/2022 | Engineer letter for frame items on file / Installers certificate and evaluation report for spray foam insulation on file / Pending field inspection | TRENTP | TRENTP | | BIN | P | 7409930 |
HOMEOWNER | BFR | P | 06/06/2022 | Still need to provide stamped copy of engineer letter for frame items / Staples used for floor truss repairs, engineered truss repair requires nails to be used, can inspect corrections at BIN / Rest okay | TRENTP | TRENTP | | BFR | P | 7400864 |
HOMEOWNER | BFR | P | 06/06/2022 | Engineer letter provided for floor joists and hinge point wall does is not stamped by licensed design professional / Truss repairs on file / Pending field inspection | TRENTP | TRENTP | | BFR | P | 7399783 |
HOMEOWNER | BFR | P | 05/27/2022 | Will inspect trusses at re inspection // 1. Hinge points present at north and west walls at upper floor stairs, will need licensed design professional clarification if repair is required / 2. Need to provide truss repair details for A floor trusses at garage/dwelling wall / 3. Need to provide truss repair details for D floor truss at rear deck cover / 4. Plans call for TJI210 floor joists in basement, LPI530 joists installed instead, will need licensed design professional clarification for change / Discussed fire protection of floors and foam plastics requirements with homeowner / Unfinished basement, rear deck | TRENTP | TRENTP | | BFR | P | 7392404 |
HOMEOWNER | BSP | P | 05/17/2022 | Inspection changed to BSP, not ready for frame, site visit used to discuss frame inspection requirements, and inspect exterior framing // Discussed fireblocking/draftstopping, hardware requirements per manufacture, and fire protection of floors with homeowner // Front porch lid okay, still need to inspect posts / Rear deck frame okay, still need to inspect stairs / Rear deck cover not inspected at this time due to needing splice, see note // Note: Truss designs and hardware requirements per structural plan do not match, will need updated truss designs, layout, and structurals updated in plans as splice | TRENTP | TRENTP | | BSP | P | 7379058 |
HOMEOWNER | BFD | C | 12/06/2021 | Engineer letter for perimeter drain on file -- Damp proofing noted / | TRENTP | TRENTP | | BFD | C | 7197791 |
HOMEOWNER | BFN | C | 12/06/2021 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 7197788 |
HOMEOWNER | BFT | C | 12/06/2021 | Footing, foundation and drain observation letter on file / open hole on file -- 5000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | TRENTP | TRENTP | | BFT | C | 7197783 |
HOMEOWNER | BSP | P | 10/07/2021 | rear deck (5) piers ok | CHRISTYB | CHRISTYB | | BSP | P | 7134412 |
HOMEOWNER | BFD | R | 07/14/2021 | Drain not ready at time of inspection, discussed drain design per foundation design on file with home owner / Request re inspection once complete / Note: Will need to provide licensed design professional observation for installation of pre cast foundation walls to complete BFN | TRENTP | TRENTP | | BFD | R | 7035904 |
HOMEOWNER | BFT | C | 07/08/2021 | Foundation design provided does not state soil bearing capacity the foundation was designed for / Soils report on file / Update by TP changed to complete after further review soil bearing capacity noted on front page of foundation design, bearing capacity confirmed | TRENTP | TRENTP | | BFT | C | 7028236 |
HOMEOWNER | BFT | P | 07/07/2021 | Need to provide soils report referenced in open hole provided / Need to provide stamped foundation design with soil bearing capacity referenced / Open hole on file, 5000 psf - usable, footing observed at previous inspection | TRENTP | TRENTP | | BFT | P | 7026383 |
HOMEOWNER | BFT | P | 06/03/2021 | Crushed stone foundation per plan / Need open hole letter uploaded / | ERIKK | ERIKK | | BFT | P | 6990196 |
HOMEOWNER | E= | C | 08/29/2022 | | BRET | BRET | | E= | C | 7499408 |
HOMEOWNER | E= | R | 08/26/2022 | OUTSIDE OUTLETS NEED INUSE COVERS ----- GFCI OUTLET CAN NOT BE BEHIND WASHER ----- REST OK ---- 60 AMP A/C ----- | GREGM | GREGM | | E= | R | 7496962 |
HOMEOWNER | ES | C | 04/19/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 7378135 |
HOMEOWNER | ES | C | 04/19/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 7441299 |
HOMEOWNER | ER | C | 04/19/2022 | 3 - # 6 CU , 3 - # 10 , no mcc , no central vac , unfinished basement , sub-panel in garage , flanged outlet on outside , RV panel on outside , | TOMC | TOMC | | ER | C | 7378134 |
HOMEOWNER | ER | C | 04/19/2022 | 3 - # 6 CU , 3 - # 10 , no mcc , no central vac , unfinished basement , sub-panel in garage , flanged outlet on outside , RV panel on outside , | TOMC | TOMC | | ER | C | 7441298 |
HOMEOWNER | EE | P | 02/16/2022 | | AMYP | AMYP | | EE | P | 7378133 |
HOMEOWNER | EE | P | 02/16/2022 | | AMYP | AMYP | | EE | P | 7441297 |
HOMEOWNER | EUG | C | 08/30/2021 | #2 bare CU around entire house , #10 uf to well | TOMC | TOMC | | EUG | C | 7378132 |
HOMEOWNER | EUG | C | 08/30/2021 | #2 bare CU around entire house , #10 uf to well | TOMC | TOMC | | EUG | C | 7441296 |
HOMEOWNER | EUG | P | 06/14/2021 | 4/0 urd------------------ changed to partial by Seebach for inspection for well wiring and ground ring installation | TOMC | TOMC | | EUG | P | 7441295 |
HOMEOWNER | EUG | P | 06/14/2021 | 4/0 urd------------------ changed to partial by Seebach for inspection for well wiring and ground ring installation | TOMC | TOMC | | EUG | P | 7378131 |
AIR CONCEPTS HEATING & COOLING | H= | C | 09/27/2022 | No coil change letter needed, see page 144 in plan design / Correction made, see images. | SAMS | SAMS | | H= | C | 7530732 |
AIR CONCEPTS HEATING & COOLING | H= | P | 09/23/2022 | Provide equipment change letter for coil / Upper level south east bedroom lacks return air path / Whole house ventilation being achieved with dampered outside air duct to furnace return. / Whole house ventilation switch located at furnace / NOTE / Unfinished basement / Outside air with damper to furnace return / Direct vent furnace / Electric water heater / A/C complete / | CASEYM | CASEYM | | H= | P | 7528711 |
HOMEOWNER | HC | C | 07/11/2022 | RELEASE METER | ANGELW | ANGELW | | HC | C | 7441113 |
HOMEOWNER | HO | C | 07/11/2022 | 10 LB TEST OK ON 40 FEET 1" PE WITH TRACER WIRE FROM RISER GOING INTO HOUSE TO METER LOCATION AROUND CORNER / OK TO COVER / | ANGELW | ANGELW | | HO | C | 7441109 |
AIR CONCEPTS HEATING & COOLING | HI | C | 05/16/2022 | Correction for 1/2" CSST for dryer stub: at 50' good for up to 37K BTUs | CASEYM | CASEYM | | HI | C | 7376843 |
HOMEOWNER | HRR | C | 05/13/2022 | **HO must be completed before releasing meter** Received mechanical splice (Dated 5-10-22 on plans) / Outside air has been been added and supply takeoffs in question have been addressed / | CASEYM | CASEYM | | HRR | C | 7376076 |
AIR CONCEPTS HEATING & COOLING | HRR | P | 05/11/2022 | Per conversation with homeowner: Contractor has submitted revised plans to plan review for new mechanical splice to address mis-sized supplies and outside air/ Not received at time of inspection/ | CASEYM | CASEYM | | HRR | P | 7371647 |
HOMEOWNER | HRR | P | 05/06/2022 | While completing HI and HV inspections, noticed that an outside air to furnace return was installed/ Plans do not show outside air/ Remove outside air by next inspection/ See previous HRR comments for all other corrections still needing to be made/ | CASEYM | CASEYM | | HRR | P | 7366321 |
AIR CONCEPTS HEATING & COOLING | HI | P | 05/05/2022 | After conversation with contractor, HI needs to be re-inspected due to location of meter and and underground gas line that is not installed yet. Gas line inspected previously was only sized to exterior wall, not to proposed meter location. | CASEYM | CASEYM | | HI | P | 7365345 |
AIR CONCEPTS HEATING & COOLING | HV | C | 05/05/2022 | Corrections made/ Main level fireplace clearance to combustibles and vent termination ok. / Non-combustible materials installed / | CASEYM | CASEYM | | HV | C | 7365343 |
AIR CONCEPTS HEATING & COOLING | HV | P | 05/04/2022 | Install standoffs, nail tabs and non-combustible material per installation instructions/ | CASEYM | CASEYM | | HV | P | 7363685 |
AIR CONCEPTS HEATING & COOLING | HI | P | 05/04/2022 | All Homflex CSST runs must be bonded per manufacturers instructions / Will need HO inspection for underground pipe/ NOTE / 10 lb test ok / 1 inch main / 1 furnace / 1 fireplace / 1 range / One 1/2" stub for dryer good for up to 67K BTUs at 20' | CASEYM | CASEYM | | HI | P | 7363677 |
AIR CONCEPTS HEATING & COOLING | HRR | P | 03/30/2022 | REQUIRED BY FINAL: Equipment change forms for both furnace and indoor coil / CONTRACTOR TO ADDRESS THE FOLLOWING: Installation instructions for HRV required on site / 2 4" supply air ducts in basement are shown as 5" ducts on approved plans (page 138) also missing a 4" supply air duct to upper level in mechanical room. Install per approved plans / Mechanical Rough pending HI and HV inspections / Whole House Ventilation being achieved with exhaust fan located in master bathroom / Verify Whole House Ventilation Switch location at final / NOTE / A/C ROUGH LINESET AND COIL / NO OUTSIDE AIR TO FURNACE RETURN / FINISHED BASEMENT / DIRECT VENT FURNACE / ELECTRIC WATER HEATER / | ANGELW | ANGELW | | HRR | P | 7319896 |
DMB PLUMBING SERVICES INC. | P= | C | 09/12/2022 | | LEE | LEE | | P= | C | 7513130 |
DMB PLUMBING SERVICES INC. | P= | P | 09/09/2022 | MISSING AAV @ RIGHT HALL LAV -- REST OK -- Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | LEE | LEE | | P= | P | 7511371 |
HOMEOWNER | PSP | P | 09/09/2022 | ENTRY FOR POTABLE WATER CERT | LEE | LEE | | PSP | P | 7511056 |
DMB PLUMBING SERVICES INC. | P= | P | 09/06/2022 | anchor rear hose bib, need hammer arrestors at washer, no hot water at master tub, need vacuum breaker at cold side for water heater, missing aav's at right hall bath lav and basement lav riser, install pan drain for water heater, need certificate of potable water, install T- tape at aav for main floor lav, rest ok, unfinished basement, no irrigation. | TAYLOR | TAYLOR | | P= | P | 7506836 |
DMB PLUMBING SERVICES INC. | PTO | C | 01/05/2022 | note: unfinished basement, aav @ RH upstairs hall lav, main floor lav, basement lav, cwv @ LH upstairs hall lav, both master lavs, at final check water piping to water heater, electric water heater, | JOSEPHD | JOSEPHD | | PTO | C | 7229058 |
DMB PLUMBING SERVICES INC. | PWO | C | 08/27/2021 | need potable water certification by final | JOSEPHD | JOSEPHD | | PWO | C | 7088155 |
DMB PLUMBING SERVICES INC. | PB | C | 06/25/2021 | | JOSEPHD | JOSEPHD | | PB | C | 7015854 |
DMB PLUMBING SERVICES INC. | PB | P | 06/24/2021 | 3" stack lacking 10 times the pipe diameter down stream to floor drain branch (p3005.5), rest ok note: no water stubbed in at this time will need PWO inspection | JOSEPHD | JOSEPHD | | PB | P | 7014314 |
HOMEOWNER | XBS | T | 05/25/2022 | PAID (REC#1870196): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revised trusses | MICHAELA | MICHAELA | | XBS | T | 7388308 |
HOMEOWNER | XMS | T | 05/10/2022 | PAID (REC#1867290) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: Approved new splice revised duct design. | TCRIPPEN | TCRIPPEN | | XMS | T | 7369660 |
HOMEOWNER | XBS | P | 03/23/2022 | PLAN SPLICE: (No Fee) by: MICHAELA for Construction: The use of the garage for the accessible route is not connected to ANSI Type C units as these units are not addressed in the IBC. | MICHAELA | MICHAELA | | XBS | P | 7311462 |