RAMPART CONSTRUCTION | B= | C | 12/27/2022 | | BOBF | BOBF | | B= | C | 7620061 |
RAMPART CONSTRUCTION | B= | P | 12/27/2022 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / -- Schedule a new Building Final when above items are complete. | GREGT | GREGT | | B= | P | 7619487 |
RAMPART CONSTRUCTION | BLA | C | 05/10/2022 | | TRENTP | TRENTP | | BLA | C | 7369798 |
RAMPART CONSTRUCTION | BIN | C | 04/08/2022 | 3rd Party Insulation Certificate on file / Note: Need to provide air leakage test results by final | TRENTP | TRENTP | | BIN | C | 7331003 |
RAMPART CONSTRUCTION | BFR | C | 03/31/2022 | Met with site rep items complete | PAULP | PAULP | | BFR | C | 7321394 |
RAMPART CONSTRUCTION | BFR | R | 03/25/2022 | Still not dried in at master closet attic window / Still need to tie in top plate at southeast corner of exterior deck fireplace, rim joist not required per engineer letter on file / Rest of items corrected | TRENTP | TRENTP | | BFR | R | 7314620 |
RAMPART CONSTRUCTION | BFR | L | 03/10/2022 | Cancelled by contractor (Doug) | TRENTP | TRENTP | | BFR | L | 7296741 |
RAMPART CONSTRUCTION | BFR | L | 03/09/2022 | Cancelled by contractor / Note: Still need to complete splice per item #6 from previous inspection / Splice required, please submit splice for changes in scope. If unfamiliar in submitting electronic splice, please click the following link: https://youtu.be/dG3kHpgDP0w / | TRENTP | TRENTP | | BFR | L | 7295119 |
RAMPART CONSTRUCTION | BFN | C | 03/08/2022 | Updated foundation design on file, bearing capacity verified | TRENTP | TRENTP | | BFN | C | 7293535 |
RAMPART CONSTRUCTION | BSP | P | 03/03/2022 | Changed to BSP / Truss repair details on file / Note: Still need to complete BFN and complete requested splice / No field inspection performed | TRENTP | TRENTP | | BSP | P | 7288539 |
RAMPART CONSTRUCTION | BSP | P | 03/03/2022 | Engineer letter for frame items on file | TRENTP | TRENTP | | BSP | P | 7288537 |
RAMPART CONSTRUCTION | BFN | P | 03/01/2022 | Foundation design provided still reflects that garage is slab on grade, provide updated foundation design / Structural garage floor foundation design on file / Structural garage floor observation on file | TRENTP | TRENTP | | BFN | P | 7285336 |
RAMPART CONSTRUCTION | BFI | C | 02/28/2022 | Designer letter for foundation insulation on file / Note: Need to complete BFN | TRENTP | TRENTP | | BFI | C | 7283611 |
RAMPART CONSTRUCTION | BFD | C | 02/28/2022 | Engineer letter for perimeter drain on file -- Damp proofing noted / Note: Need to complete BFN | TRENTP | TRENTP | | BFD | C | 7283608 |
RAMPART CONSTRUCTION | BFR | R | 02/25/2022 | Need to inspect trusses at re inspection once foundation inspections are complete /// 1. Still need to complete BFD and BFI, Need to provide all requested paperwork for BFN per updated inspection notes prior to further inspection / 2. Missing rim joists per plan at exterior deck fireplace chase / 3. Incomplete dry in at garage service door, great room transom, and gable truss window in master closet attic / 4. Top chord of A2 drilled in upper garage loft / 5. Missing hangers at cantilevered floor joists over basement stairs per detail 4/S-2 / 6. Need splice for added storage vault under garage not on plans, plans and foundation design show garage to be slab on grade, storage vault is entire area of garage with 2/3 with ceiling height of 10 ft 6 inches and 1/3 with a ceiling height of 7ft 8 inches, need to provide update foundation design and observation to BFN / 7. Need to provide repair or head out cut floor joist at PVC pipes in mechanical room / 8. Need to provide licensed design professional clarification for use of steel brackets at wet bar and to right of basement stairs for LVLs / 3/4 finished basement, rear deck / Note: Will need to observed upper floor and deck stairs when installed | TRENTP | TRENTP | | BFR | R | 7283046 |
RAMPART CONSTRUCTION | BFN | P | 02/25/2022 | Foundation design on file (Bearing Capacity Verified) / Update by TP on 2/26/22: After further review, changed to partial, need updated foundation design and foundation observation for added storage vault under garage not on design or plans, current design shows slab on grade | TRENTP | TRENTP | | BFN | P | 7282198 |
RAMPART CONSTRUCTION | BFT | C | 02/25/2022 | Stamped open hole on file, 3000 psf - usable -10% | TRENTP | TRENTP | | BFT | C | 7282165 |
RAMPART CONSTRUCTION | BFN | P | 02/22/2022 | Still need to complete BFT / Still need stamped open hole, field copy not stamped / Footing/foundation observation on file | TRENTP | TRENTP | | BFN | P | 7277443 |
RAMPART CONSTRUCTION | BSP | T | 02/18/2022 | PAID (REC#1845014): Inspection stopped and changed to BSP after too many items, will need full re inspection, only inspected through garage and upper garage loft, and exterior fireplace chase / 1. Need to complete all foundation inspections prior to further inspection / 2. Missing required ledger fasteners at front deck / 3. Incorrect fasteners used in HUS612 at rear deck for gluelam beam / 4. HUC hanger missing fasteners in exterior fireplace chase, lower level at deck / 5. Missing rim joists in exterior fireplace chase at deck per plan, top plates interupted / 6. Missing garage service door for dry in / 7. Missing blocking at garage door brackets / 8. Anchor bolts at western garage wall do not take place in middle third of plate / 9. Missing anchor bolts within 12 inches of plate break at western garage wall / 10. Missing anchor bolts within 12 inches of plate breaks in multiple areas at eastern garage wall / 11. Northern corners of upper garage stair landing not supported / 12. Inco | TRENTP | TRENTP | | BSP | T | 7276253 |
RAMPART CONSTRUCTION | BFN | P | 02/18/2022 | Need to complete BFT / Need to provide stamped open hole, field copy not stamped / Need to provide foundation observation / Soils report on file / Foundation design on file, need to verify bearing capacity | TRENTP | TRENTP | | BFN | P | 7275443 |
RAMPART CONSTRUCTION | BIN | P | 02/17/2022 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 7275181 |
RAMPART CONSTRUCTION | BSP | P | 01/18/2022 | Front deck frame and posts ok / Rear deck frame and posts ok / Rear covered porch lid and posts ok / | ERIKK | ERIKK | | BSP | P | 7242337 |
RAMPART CONSTRUCTION | BTR | P | 11/18/2021 | Missing flashings on vents penetrating through roof on lower front right elevation. / Please make correction. / Please upload photos of compliance with a new inspection request. | MATTHEWA | MATTHEWA | | BTR | P | 7182592 |
RAMPART CONSTRUCTION | BFI | P | 06/10/2021 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFI | P | 6997451 |
RAMPART CONSTRUCTION | BFT | P | 06/10/2021 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 6997450 |
RAMPART CONSTRUCTION | BFN | P | 06/10/2021 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 6997449 |
A N' M ELECTRIC | E= | C | 12/21/2022 | E= OK ----- A/C # 1 20 AMP --- A/C # 2 50 AMP ------ | GREGM | GREGM | | E= | C | 7617479 |
A N' M ELECTRIC | ES | C | 02/10/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 7265919 |
A N' M ELECTRIC | ER | C | 02/10/2022 | sub-panels in garage and basement | TOMC | TOMC | | ER | C | 7265918 |
A N' M ELECTRIC | EP | C | 02/10/2022 | 1 - 4/0 AL , 1 - # 2 AL , 4 - # 6 AL , 2 - # 10 , irreversible ufer , finished basement , transfer switch outside | TOMC | TOMC | | EP | C | 7265915 |
A N' M ELECTRIC | ESL | C | 08/05/2021 | 4- floor boxes | TOMC | TOMC | | ESL | C | 7062712 |
A N' M ELECTRIC | EUG | C | 08/05/2021 | 250 urd | TOMC | TOMC | | EUG | C | 7062709 |
A & Z MECHANICAL, INC. | H= | C | 12/22/2022 | CORRECTIONS MADE, MECHANICAL FINAL COMPLETE / Whole house ventilation being achieved with exhaust fan located in laundry room. / Whole house ventilation switch located in mechanical room / | WHITNEYH | WHITNEYH | | H= | C | 7619354 |
A & Z MECHANICAL, INC. | H= | P | 12/21/2022 | REMOVE BRASS VENT LIMITER AND INSTALL VENT PROTECTOR FOR MEDIUM PRESSURE REGULATOR FOR MAIN AT EXTERIOR OF HOME, MANUFACTURER REQUIRED WHEN INSTALLED OUTDOORS / UNABLE TO LOCATE EXHAUST FAN FOR UPPER LEVEL BATHROOM, APPEARS IT'S BEEN CONCEALED BENEATH DRYWALL / INSTALL DAMPER FOR MAKE-UP AIR WITHIN MECHANICAL ROOM, AND INTERLOCK WITH RANGE EXHAUST / MECHANICAL ROOM MUST COMMUNICATE WITH AREA RANGE EXHAUST IS LOCATED-OPEN STAIRWELL, BUT SOLID DOOR IN PLACE AT MECHANICAL ROOM / UNABLE TO LOCATE WHOLE HOUSE VENTILATION SWITCH IN LAUNDRY ROOM / PER GENERAL CONTRACTOR GENERATOR TO BE INSTALLED IN FUTURE UNDER SEPARATE PERMIT AND INSPECTION / Whole house ventilation being achieved with exhaust fan located in laundry room. / Unable to locate whole house ventilation switch / NOTE / PARTIAL FINISHED BASEMENT / DIRECT VENT BOILER / HIGH VELOCITY LOW DIAMETER SYSTEM FOR A/C X2 / | WHITNEYH | WHITNEYH | | H= | P | 7617835 |
R AND D PLUMBING | HO+ | C | 09/28/2022 | **UPDATE 10-03-2022 CM ** Removed 20' of 3/4" PE from previously installed 105' line to generator / 10lb test ok on remaining total length of 85', verify regulator at final /
10lb test ok on 105' of 3/4" PE with tracer wire from riser at house to generator / Verify regulator set at generator at final / Ok to cover / | CASEYM | CASEYM | | HO+ | C | 7532915 |
R AND D PLUMBING | HWP | C | 05/12/2022 | TEST ON REMAINING UPPER LEVEL ZONES OK | JHORSMAN | JHORSMAN | | HWP | C | 7373209 |
R AND D PLUMBING | HC | C | 04/08/2022 | ADDED LOAD OF 4540 DARR CIR TO METER UTILIZED FOR 4530 DARR CIR/ SYSTEM IS EXISTING 2 LB PER BUILD INSPECTION OF 4530 DARR CIR. | JHORSMAN | JHORSMAN | | HC | C | 7331872 |
R AND D PLUMBING | HO | C | 04/08/2022 | BY FINAL LABEL ALL GAS PIPE UNDER MEDIUM PRESSURE AND CONNECT RISER TO HOUSE MAIN/ 10 LB TEST OK ON UNDERGROUND GAS LINE FROM METER AT ROAD TO RISER AT HOUSE / 2 LB APPROVAL LETTER ON FILE UNDER PERMIT L05352 | JHORSMAN | JHORSMAN | | HO | C | 7331866 |
R AND D PLUMBING | HSP | P | 04/08/2022 | per contractor 4540 Darr will share a meter with the Mother in Law suite that has address 4530 Darr. according to build permit L05352 meter is a 2 lb meter. Per contractor 4540 Darr underground gas line will be taken from the meter to the new house. Inspector will verify connection tie in at inspection. Per permit L05352 the existing underground gas line will not be required to be re-tested due to already being under medium pressure and only the new underground gas line will require the pressure test. | JHORSMAN | JHORSMAN | | HSP | P | 7330966 |
R AND D PLUMBING | HI | C | 02/17/2022 | PER CONTRACTOR METER UTILIZED WILL BE FROM PRIMARY HOME TO NEW BUILD. BY FINAL WILL NEED HO FOR UNDERGROUND GAS LINE FROM CURRENT UNDERGROUND LINE AND A 10 LB PRESSURE TEST ON ALL GAS PIPING THAT WILL BE UNDER 2 LB PRESSURE FOR NEW HOME AND EXISTING FROM THE METER. BY FINAL PROVIDE 2 LB APPROVAL LETTER AS ONE CANNOT BE FOUND FOR ORIGINAL ADDRESS, MEDIUM PRESSURE STENCILING, AND REGULATOR/ 10 LB TEST OK/ 2 INCH MAIN / 1 BOILER / 1 RANGE / 5 FIREPLACES / ONE 3/4 INCH STUB UNDER THE DECK GOOD FOR UP TO 83K BTUS AT 71 FEET/ ONE 1 INCH STUB IN THE GARAGE FOR FUTURE USE GOOD FOR UP TO 175 BTUS AT 85 FEET | JHORSMAN | JHORSMAN | | HI | C | 7274473 |
FIREPLACE WAREHOUSE | HV | C | 02/17/2022 | PATIO CLEARANCES TO COMBUSTIBLES OK, FRONT VENT FIREPLACE | JHORSMAN | JHORSMAN | | HV | C | 7274470 |
FIREPLACE WAREHOUSE | HV | P | 02/17/2022 | PICTURE OF PATIO FIREPLACE SECURED, SEE IMAGES/ WILL SCHEDULE ON SITE INSPECTION TO VERIFY CLEARANCE TO COMBUSTIBLES | JHORSMAN | JHORSMAN | | HV | P | 7273628 |
FIREPLACE WAREHOUSE | HV | P | 02/15/2022 | SECURE PATIO FIREPLACE AND COMPLETE FRAMING/ LIVING ROOM FIREPLACE CLEARANCES TO COMBUSTIBLES AND VENT TERMINATION OK, NON-COMBUSTIBLE MATERIALS INSTALLED/ GREAT ROOM FIREPLACE FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK/ BEDROOM FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK, NON-COMBUSTIBLE MATERIALS INSTALLED/ BASEMENT FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / | JHORSMAN | JHORSMAN | | HV | P | 7271370 |
A & Z MECHANICAL, INC. | HRR | C | 02/15/2022 | AT FINAL VERIFY MAKE UP AIR DAMPER AND KITCHEN HOOD CONNECTION | JHORSMAN | JHORSMAN | | HRR | C | 7271343 |
FIREPLACE WAREHOUSE | HV | P | 02/15/2022 | PICTURES OF VENTING AT ROOF DECK CORRECTION RECEIVED, SEE IMAGES/ WILL SCHEDULE ON SITE INSPECTION TO VERIFY PATIO FIREPLACE IS SECURED | JHORSMAN | JHORSMAN | | HV | P | 7270489 |
A & Z MECHANICAL, INC. | HRR | P | 02/10/2022 | INSTALL FRAMING AROUND BOILER VENTING ON MAIN LEVEL/ PROVIDE BOILER INSTALLATION INSTRUCTION/ MAKE UP AIR FOR COOK TOP EXHAUST INSTALLED, VERIFY COOKTOP FAN AND DAMPER WIRED SO DAMPER OPENS WHEN FAN IS TURNED ON AT FINAL Whole house ventilation being achieved with exhaust fan located in laundry room. / Verify whole house ventilation switch location at final / NOTE / FINISHED BASEMENT / DIRECT VENT BOILER / HIGH VELOCITY AIR SYSTEMS USING BOILER HEAT AND A/C COOLING X2/ A/C ROUGH, COIL AND LINESET X2/ | JHORSMAN | JHORSMAN | | HRR | P | 7266062 |
R AND D PLUMBING | HI | P | 02/09/2022 | CONNECT GAS LINE INTO DECK FIREPLACE/
PER CONTRACTOR HAS LINE WILL TIE INTO THE EXISTING UNDERGROUND GAS LINE FOR THE MOTHER IN LAW SUITE. WILL NEED HO INSPECTION ONCE THAT GAS LINE IS INSTALLED PRIOR TO COMPLETING HEAT FINAL/ 10 LB TEST OK / 2 INCH MAIN / 1 BOILER / 1 RANGE / 5 FIREPLACES / | JHORSMAN | JHORSMAN | | HI | P | 7265069 |
FIREPLACE WAREHOUSE | HV | P | 02/09/2022 | CONTRACTOR TO PROVIDE INFORMATION ON LIVING ROOM FIREPLACE INSULATION SHIELD, CURRENT INSULATION SHIELD IS IN PLACE FOR SPRAY FOAM AND BLOWN INSULATION. IF SPRAY FOAM INSULATION WILL NEED A TIGHT FIT WHERE IT PASSES THROUGH THE ROOF DECK/ GREAT ROOM AND BEDROOM FIREPLACE VENTS NEED TO BE SEALED AT ROOF DECK TO NOT ALLOW SPRAY FOAM TO ENTER INSULATION SHIELD. SECURE DECK FIREPLACE AND COMPLETE FRAMING | JHORSMAN | JHORSMAN | | HV | P | 7265063 |
R AND D PLUMBING | HWP | P | 10/06/2021 | 60 LB TEST ON GARAGE RADIANT HEATING OK/ OK TO COVER/ WILL THERE ME MORE ZONES INSTALLED LATER? | JHORSMAN | JHORSMAN | | HWP | P | 7132126 |
R AND D PLUMBING | HWP | P | 08/05/2021 | 60 LB TEST ON ONE GAUGE ON THE LOWER LEVEL OK/ OK TO COVER/ WILL THERE BE MORE? | JHORSMAN | JHORSMAN | | HWP | P | 7061684 |
R AND D PLUMBING | P= | C | 12/21/2022 | HAS PVB FOR IRRIGATION -- NOTE: PWO TIED TO EXISTING LINE, NO POTABLE H20 CERT REQUIRED | LEE | LEE | | P= | C | 7618156 |
R AND D PLUMBING | PTO | C | 02/09/2022 | note: finished basement(2 bathrooms finished), irrigation stub, running trap to dog wash in garage, need tempering for master tub by final, aav @ all lavs, wet bar, in upstairs mech room, in basement mech room, bathroom above garage is dwv rough only, check boiler backflow at final, check steam unit at final, check side arm at final, attic to be conditioned check for foam insulation for water lines at final, | JOSEPHD | JOSEPHD | | PTO | C | 7264501 |
HOMEOWNER | PWO | P | 10/28/2021 | need to uncover connection at well head, is this using the same well as the house next door? rest ok | JOSEPHD | JOSEPHD | | PWO | P | 7157968 |
R AND D PLUMBING | PB | C | 07/23/2021 | note: will need PWO insepcton | JOSEPHD | JOSEPHD | | PB | C | 7046868 |
R AND D PLUMBING | PB | P | 07/20/2021 | install and test trap for shower, rest ok, note: H2O under footer. | TAYLOR | TAYLOR | | PB | P | 7042693 |
RAMPART CONSTRUCTION | XBS | T | 03/24/2022 | PAID (REC#1853314): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Added 1112 sf to basement by doing a structural garage floor. | SHELLEY | SHELLEY | | XBS | T | 7312722 |