HAMMERS CONSTRUCTION, INC | B= | C | 04/01/2022 | Items corrected, photos on file | TRENTP | TRENTP | | B= | C | 7322671 |
HAMMERS CONSTRUCTION, INC | B= | P | 03/11/2022 | Need to complete both open mechanical attachments on permit / Need to provide weather protective exterior at each side of garage openings / Missing lights at front next to garage door and next to rear kitchen door / Missing tip outs for downspouts -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): DISTINCTIVE MANTLE DESIGNS, INC. Mechanical Final Inspection is not Completed yet, MARTINSON MECHANICAL, INC Mechanical Final Inspection is not Completed yet. | TRENTP | TRENTP | | B= | P | 7298692 |
HAMMERS CONSTRUCTION, INC | BFR | C | 01/04/2022 | BFD completed | JASONB | JASONB | | BFR | C | 7228162 |
HAMMERS CONSTRUCTION, INC | BFD | C | 01/04/2022 | Damp proof and drain OK - daylight to south east of addition / GC to backfill per requirements of the soils report | JASONB | JASONB | | BFD | C | 7228160 |
HAMMERS CONSTRUCTION, INC | BLA | C | 12/23/2021 | Lath ok / | ERIKK | ERIKK | | BLA | C | 7220297 |
HAMMERS CONSTRUCTION, INC | BSP | R | 12/20/2021 | Equipment change form to be submitted and approved by plan review as splice | TRENTP | TRENTP | | BSP | R | 7214214 |
HAMMERS CONSTRUCTION, INC | BIN | P | 12/17/2021 | Need to complete BFD and BFR / Wall insulation okay / Will inspect attic and crawlspace insulation at final / Discussed thermal envelope requirements with contractor onsite | TRENTP | TRENTP | | BIN | P | 7213580 |
HAMMERS CONSTRUCTION, INC | BFR | P | 12/14/2021 | Still need to complete BFD / Frame items corrected | TRENTP | TRENTP | | BFR | P | 7208665 |
HAMMERS CONSTRUCTION, INC | BFN | C | 12/14/2021 | Updated foundation design spliced to plans, bearing capacity verified, no changes to foundation | TRENTP | TRENTP | | BFN | C | 7207608 |
HAMMERS CONSTRUCTION, INC | BFR | R | 12/13/2021 | Still need to complete foundation inspections and other roughs prior to re inspection of frame / No inspection performed | TRENTP | TRENTP | | BFR | R | 7206160 |
HAMMERS CONSTRUCTION, INC | BFR | R | 12/09/2021 | Still need to complete foundation inspections and other roughs prior to re inspection of frame / No inspection performed | TRENTP | TRENTP | | BFR | R | 7202913 |
HAMMERS CONSTRUCTION, INC | BFN | P | 12/09/2021 | Changed to BFN / Revised open hole provided (3000psf) still has lower bearing capacity than foundation design on file (3500psf) | TRENTP | TRENTP | | BFN | P | 7202903 |
HAMMERS CONSTRUCTION, INC | BFR | R | 12/07/2021 | Still need to complete foundation inspections and other roughs prior to re inspection of frame / No inspection performed | TRENTP | TRENTP | | BFR | R | 7199517 |
HAMMERS CONSTRUCTION, INC | BFN | P | 12/07/2021 | Bearing capacity of foundation design (3500 psf) is not less than or equal to bearing capacity of open hole (2400 psf) / Note: Need to complete BFD | TRENTP | TRENTP | | BFN | P | 7199468 |
HAMMERS CONSTRUCTION, INC | BFT | C | 12/07/2021 | Soils report and open hole on file, 2400 psf - 5% - usable | TRENTP | TRENTP | | BFT | C | 7199459 |
HAMMERS CONSTRUCTION, INC | BFR | R | 12/03/2021 | 1. Need to complete foundation inspections prior to further inspection / 2. Missing blocking at garage door brackets / 3. Missing fireblocking throughout / 4. Missing H2.5s at jack trusses at fire place / 5. Missing all required bracing of trusses per engineer details in plans | TRENTP | TRENTP | | BFR | R | 7197323 |
HAMMERS CONSTRUCTION, INC | BFI | C | 10/08/2021 | Designer letter for foundation insulation on file / | CHAD | CHAD | | BFI | C | 7134767 |
HAMMERS CONSTRUCTION, INC | BFN | P | 10/08/2021 | Changed to BFN / Complete BFT / Engineer letter for foundation on file -- Eufer noted / | CHAD | CHAD | | BFN | P | 7134763 |
HAMMERS CONSTRUCTION, INC | BSP | P | 10/05/2021 | Partial inspection for floor joists, joist, ledgers and beams okay / Still will need to inspect floor at BFR / Note: Need to complete all foundation inspections | TRENTP | TRENTP | | BSP | P | 7130520 |
HAMMERS CONSTRUCTION, INC | BFT | P | 10/05/2021 | Inspection changed to BFT / Need to provide soils report and open hole / Footing observation on file / Foundation design in plans / Note: Need to complete BFN | TRENTP | TRENTP | | BFT | P | 7129962 |
SYSTEMS ELECTRIC, INC. | E= | C | 03/11/2022 | E= OK ---- 20 AMP A/C ----- | GREGM | GREGM | | E= | C | 7298196 |
SYSTEMS ELECTRIC, INC. | ES | C | 12/07/2021 | Residential Underground: 200-amp 3 Wire New Residence ok NEED METER SEAL. / | GREGM | GREGM | | ES | C | 7200418 |
SYSTEMS ELECTRIC, INC. | ER | C | 12/07/2021 | ER OK ---- CHECK SUB PANEL IN EXISTING GARAGE AND FIREPLACE CONNECTION AT FINAL ------ | GREGM | GREGM | | ER | C | 7200407 |
SYSTEMS ELECTRIC, INC. | ES | R | 12/03/2021 | Residential Underground: REMOVE UFER FROM SUB PANEL ---- REST OK ----- | GREGM | GREGM | | ES | R | 7196923 |
SYSTEMS ELECTRIC, INC. | ER | R | 12/03/2021 | MOVE GARAGE OUTLETS ABOVE 18" --- WIRE BATH FAN --- OUTLET GARAGE WALL IN KITCHEN NEEDS TO BE ON APPL. CIRCUIT ---- GROUND SCREWS IN ALL METAL BOXES --- FIREPLACE NEEDS TO BE INSTALLED ---- REST OK ---- 4/O SER TO SUB PANEL --- #10 A/C --- NO MCC --- IRR UFER ----- | GREGM | GREGM | | ER | R | 7196918 |
MARTINSON MECHANICAL, INC | H= | C | 03/17/2022 | MECHANICAL GAS FINAL COMPLETE | ANGELW | ANGELW | | H= | C | 7305057 |
DISTINCTIVE MANTLE DESIGNS, INC. | H= | C | 03/15/2022 | FIREPLACE MANTLE CLEARANCE OK | ANGELW | ANGELW | | H= | C | 7301722 |
DISTINCTIVE MANTLE DESIGNS, INC. | H= | P | 03/14/2022 | CALL AHEAD SENT AT 10:19 AM / PROPERTY LOCKED AND NO ANSWER AT DOOR AT 11:08 AM / LEFT DOOR TAG / PLEASE RESCHEDULE INSPECTION | ANGELW | ANGELW | | H= | P | 7299999 |
THE FURNACE GUY HEATING & COOLING | H= | C | 02/18/2022 | MECHANICAL FINAL COMPLETE/ NOTE/ LOUVER DOOR TO MECHANICAL ROOM/ | JHORSMAN | JHORSMAN | | H= | C | 7276343 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/17/2022 | UPON FURTHER REVIEW WITH SENIOR INSPECTOR, DOOR DOES NOT HAVE TO HAVE A GASKET AND BE SELF CLOSING, AND DUCT WORK AND PIPING DOES NOT HAVE TO BE INSULATED. THE SUPPLY IN THE MECHANICAL ROOM MUST BE REMOVED, AND THE DUCT WORKED PATCHED, AND PROPERLY SEALED IF THE 5 INCH COMBUSTION AIR IS STAYING INSTALLED | JHORSMAN | JHORSMAN | | H= | P | 7273822 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/16/2022 | WATER HEATER IS GETTING COMBUSTION AIR VIA 5 INCH HIGH COMBUSTION AIR. MECHANICAL ROOM TO CONFORM TO IECC R402.4.4. WITH ALL DUCT AND PIPING INSULATED/ MECHANICAL ROOM IN THE GARAGE HAS A SUPPLY INSTALLED IN THE PLENUM AND REQUIRES A SELF SEALING DOOR WITH A GASKET | JHORSMAN | JHORSMAN | | H= | P | 7272567 |
THE FURNACE GUY HEATING & COOLING | HSP | P | 02/09/2022 | RECEIVED EQUIPMENT CHANGE FORM FOR FURNACE AND INDOOR COIL. PLEASE SEE IMAGES. | ANGELW | ANGELW | | HSP | P | 7263904 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/08/2022 | PROVIDE EQUIPMENT CHANGE LETTER FOR FURNACE AND COIL/ PROVIDE UPDATED EQUIPMENT CERTIFICATE TO PLAN REVIEW FOR NEW FURNACE THAT SERVES THE ADDITION, CURRENT CERTIFICATE CALLS FOR MAIN HOUSE FURNACE HEAT/ WATER HEATER NOT INSTALLED AT TIME OF INSPECTION, NEED WATER HEATER INSTALLED TO VERIFY VENT CONNECTION AND COMBUSTION AIR REQUIREMENTS/ CAP OR COMPLETE KITCHEN RANGE EXHAUST DUCT/ NOTE / CONDITIONED CRAWL SPACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / A/C COMPLETE / | JHORSMAN | JHORSMAN | | H= | P | 7262883 |
HEARTHSTONE FIREPLACE LLC | HC | C | 01/11/2022 | RELEASE METER | JHORSMAN | JHORSMAN | | HC | C | 7235472 |
HEARTHSTONE FIREPLACE LLC | HV | C | 01/11/2022 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | JHORSMAN | JHORSMAN | | HV | C | 7235467 |
MARTINSON MECHANICAL, INC | HI+ | C | 01/07/2022 | 10 LB TEST OK ON GAS LINE TO FIREPLACE / | ANGELW | ANGELW | | HI+ | C | 7231870 |
MARTINSON MECHANICAL, INC | HI | C | 12/21/2021 | FIREPLACE CONTRACTOR ATTACHED TO PERMIT | ANGELW | ANGELW | | HI | C | 7215877 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 12/21/2021 | REQUIRED BY FINAL: EQUIPMENT CHANGE FORMS FOR BOTH FURNACE AND INDOOR COIL. PLEASE SEE IMAGES FOR FURNACE AND COIL INSTALLED AT HRR / RESIDENTIAL EQUIPMENT CERTIFICATE MUST BE SUBMITTED THROUGH PLAN REVIEW TO SHOW THAT FURNACE IS TAKING CARE OF THE ADDITION ONLY, NOT THE WHOLE HOUSE / WHOLE HOUSE VENTILATION NOT REQUIRED FOR ADDITION | ANGELW | ANGELW | | HRR | C | 7215871 |
MARTINSON MECHANICAL, INC | HO | C | 12/08/2021 | 10 LB TEST ON 12 FEET 1" PE GAS LINE WITH TRACER WIRE FROM METER AT HOUSE TO NEW ADDITION OK / OK TO COVER | ANGELW | ANGELW | | HO | C | 7201836 |
MARTINSON MECHANICAL, INC | HI | P | 12/08/2021 | HI INSPECTION TO BE COMPLETED WHEN FIREPLACE CONTRACTOR ATTACHES TO PERMIT / 10 LB TEST OK / 1 FURNACE / 1 WATER HEATER / 1 FIREPLACE / | ANGELW | ANGELW | | HI | P | 7201834 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 12/03/2021 | RESIDENTIAL EQUIPMENT CERTIFICATE MUST BE RE-SUBMITTED THROUGH PLAN REVIEW TO SHOW THAT FURNACE IS TAKING CARE OF THE ADDITION ONLY, NOT THE WHOLE HOUSE. / WHOLE HOUSE VENTILATION NOT REQUIRED FOR ADDITION / ALSO PLEASE SEE PREVIOUS HRR COMMENTS | ANGELW | ANGELW | | HRR | P | 7196352 |
MARTINSON MECHANICAL, INC | HI | P | 12/03/2021 | NEED FIREPLACE CONTRACTOR TO ATTACH TO PERMIT / MUST SEE UNDERGROUND GAS LINE FROM HOUSE TO ADDITION / NEED ACCESS TO CRAWL SPACE FOR SIZING / | ANGELW | ANGELW | | HI | P | 7196343 |
MARTINSON MECHANICAL, INC | HI | P | 12/02/2021 | CONTRACTOR TO ADDRESS THE FOLLOWING: NO ACCESS TO CRAWL SPACE / THERE IS NO GAS CONNECTION RUN TO WATER HEATER (IS WATER HEATER ON GAS OR IS IT ELECTRIC? THERE IS B VENT RUN FOR WATER HEATER) / PLEASE PROVIDE BTU RATING FOR WATER HEATER AND FIREPLACE / WILL GAS LINE FOR THE ADDITION BE CONNECTED TO MAIN HOUSE METER? IF SO, WILL NEED TO VERIFY SIZING OF ENTIRE GAS LINE FOR MAIN HOUSE AND ADDITION / NOTES / 10 LB TEST OK / 1 FURNACE / 1 WATER HEATER? (NOT INSTALLED AT TIME OF INSPECTION, BUT A B VENT IS IN PLACE FOR WATER HEATER) / 1 FIREPLACE (NOT INSTALLED AT TIME OF INSPECTION) / | ANGELW | ANGELW | | HI | P | 7196276 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 11/23/2021 | REQUIRED BY FINAL: EQUIPMENT CHANGE FORMS FOR FURNACE AND INDOOR COIL. SEE IMAGES FOR FURNACE AND COIL INSTALLED AT HRR / CONTRACTOR TO ADDRESS THE FOLLOWING: WHO IS RESPONSIBLE FOR THE FIREPLACE INSTALLATION? / WHO IS RESPONSIBLE FOR GAS? / THESE CONTRACTORS MUST ATTACH TO PERMIT / Whole House Ventilation for addition being achieved with exhaust fan located in bathroom / Verify Whole House Ventilation Switch location at final / NOTES / A/C ROUGH LINESET AND COIL / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / CONDITIONED CRAWL SPACE / DIRECT VENT FURNACE / | ANGELW | ANGELW | | HRR | P | 7187284 |
MARTINSON MECHANICAL, INC | P= | C | 03/08/2022 | correction made | TREBORB | TREBORB | | P= | C | 7294691 |
HAMMERS CONSTRUCTION, INC | PWO | C | 03/08/2022 | OK | TREBORB | TREBORB | | PWO | C | 7294013 |
MARTINSON MECHANICAL, INC | P= | P | 03/08/2022 | NEED HAMMER ARRESTOR ON DISHWASHER; REST OK' PICS OK | TREBORB | TREBORB | | P= | P | 7293823 |
MARTINSON MECHANICAL, INC | PTO | C | 12/02/2021 | need PWO inspection, note: vtr 2, check water heater at final, plumbing hung in crawlspace | JOSEPHD | JOSEPHD | | PTO | C | 7195014 |
HAMMERS CONSTRUCTION, INC | XBS | T | 12/13/2021 | PAID (REC#1828996): PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Revised bearing pressure criteria on foundation plan sheet. | BPHILLIPS | BPHILLIPS | | XBS | T | 7206023 |
HAMMERS CONSTRUCTION, INC | XBS | P | 12/07/2021 | PLAN SPLICE: (No Fee) by: BPHILLIPS for Construction: Revised kitchen layout - deleted range. | BPHILLIPS | BPHILLIPS | | XBS | P | 7199324 |
HAMMERS CONSTRUCTION, INC | XBS | T | 09/15/2021 | PAID (REC#1807295): PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Revised footprint. | BPHILLIPS | BPHILLIPS | | XBS | T | 7107848 |
HAMMERS CONSTRUCTION, INC | XMS | T | 09/15/2021 | PAID (REC#1807294): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: Approved new splice had to shift addition forward because of the gas meter | TCRIPPEN | TCRIPPEN | | XMS | T | 7107483 |
HAMMERS CONSTRUCTION, INC | XBS | T | 06/29/2021 | PAID (REC#1785773): PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Deleted interior garage wall, revised floor plan at laundry. | BPHILLIPS | BPHILLIPS | | XBS | T | 7018843 |