HOMEOWNER | B= | C | 02/16/2024 | | BOBF | BOBF | | B= | C | 7998418 |
HOMEOWNER | BFR | C | 02/16/2024 | | BOBF | BOBF | | BFR | C | 7998409 |
HOMEOWNER | B= | R | 02/21/2023 | Hot tub to be inspected by electrical, please contact electrical department for inspection / Homeowner states not ready for building final, no inspection performed | TRENTP | TRENTP | | B= | R | 7665093 |
HOMEOWNER | BLA | C | 04/22/2022 | Lath okay / Wall photo on file | TRENTP | TRENTP | | BLA | C | 7348298 |
HOMEOWNER | BFR | C | 04/01/2022 | Inspection changed to BFR / Items corrected, photos on file | TRENTP | TRENTP | | BFR | C | 7322662 |
HOMEOWNER | BSP | P | 04/01/2022 | More photos of A35s on file | TRENTP | TRENTP | | BSP | P | 7322658 |
HOMEOWNER | BFR | P | 03/29/2022 | Photos of A35s on file / Still need to confirm post cap correction, can observe at final or provide photos of correction uploaded to inspection request | TRENTP | TRENTP | | BFR | P | 7317539 |
HOMEOWNER | BFR | R | 03/25/2022 | Still missing second post caps at post to beam connections / Corrections per engineer letter on file not made at time of inspection, Will accept photos of corrections uploaded to inspection requests | TRENTP | TRENTP | | BFR | R | 7314978 |
HOMEOWNER | BFR | P | 03/25/2022 | Engineer letter for frame changes on file / Pending observation of corrections | TRENTP | TRENTP | | BFR | P | 7314348 |
HOMEOWNER | BFR | R | 03/14/2022 | Need licensed design professional clarification for both beams screw to 2x6s in walls for support, beams to bear on posts with screws used as holddowns / Plans call for double H2,5Ts at each end of truss, only single H2.5s installed / Missing inverted LUS hangers at 2x4 outriggers per plan / Decorative post caps to be used in pairs | TRENTP | TRENTP | | BFR | R | 7299939 |
HOMEOWNER | B= | R | 11/09/2021 | Call ahead completed at 10:25am / Automated gate closed, no answer from call ahead / Please re schedule inspection when access may be attained. Additional Inspections Required (computer generated): HOMEOWNER Electrical Final Inspection is not Completed yet. | TRENTP | TRENTP | | B= | R | 7170254 |
HOMEOWNER | BFN | C | 11/09/2021 | See BFT | TRENTP | TRENTP | | BFN | C | 7169769 |
HOMEOWNER | BFT | C | 11/09/2021 | Changed to BFT / Engineer letter for observation of footing and foundation on file | TRENTP | TRENTP | | BFT | C | 7169765 |
HOMEOWNER | BFN | P | 10/06/2021 | Still need engineer letter for foundation observation / Two rear piers are OK and per plan / | ERIKK | ERIKK | | BFN | P | 7132543 |
HOMEOWNER | BFT | R | 09/29/2021 | Foundation wall poured at time of inspection, inspector unable to view re enforcement per engineer stamped plan / Both piers missing re enforcement per plan / Sono tubes used entire depth of piers, only first 10 inches to be used / Discussed with homeowner option of using 3rd party licensed design professional for inspection | TRENTP | TRENTP | | BFT | R | 7124450 |
HOMEOWNER | E= | C | 08/25/2023 | E= OK ----- 50 AMP HOT TUB ------ | GREGM | GREGM | | E= | C | 7837735 |
HOMEOWNER | EE | L | 08/22/2023 | Renewed for No Fee at 8/22/2023 3:36:19 PM | MATTHEW | MATTHEW | | EE | L | 7834195 |
HOMEOWNER | E= | P | 09/07/2022 | E= OK ------- still need hot tub inspected | GREGM | GREGM | | E= | P | 7508179 |
HOMEOWNER | E= | R | 08/29/2022 | label circuits in sub panel, install in-use covers, all receptacle exterior have to be w/r type, install arc-shields on patio cover receptacles installed in t &g hot tub pre-wire | BRET | BRET | | E= | R | 7499391 |
HOMEOWNER | ER | C | 03/14/2022 | Discussed AFCI/GFCI/TR requirements with owner. / covered patio , outside kitchen | TOMC | TOMC | | ER | C | 7299715 |
HOMEOWNER | ESL | C | 09/07/2021 | Two 1 inch pvc conduits | JOSEPH | JOSEPH | | ESL | C | 7169775 |
HOMEOWNER | H= | C | 05/19/2022 | | JHORSMAN | JHORSMAN | | H= | C | 7382338 |
HOMEOWNER | HC | C | 05/19/2022 | ADDED 61K BTUS TO EXISTING LOAD | JHORSMAN | JHORSMAN | | HC | C | 7382336 |
HOMEOWNER | HO | C | 05/19/2022 | | JHORSMAN | JHORSMAN | | HO | C | 7382316 |
HOMEOWNER | HO | P | 05/18/2022 | PER MANUFACTURE INSTRUCTIONS BBQ FRAMING TO BE MADE OF NON-COMBUSTIBLE MATERIALS/ 10 LB TEST OK ON ADDED 8 FEET OF 1/2 INCH BLACK FROM EXISTING STUB TO NEW 61K BTU BBQ | JHORSMAN | JHORSMAN | | HO | P | 7380369 |