HENSEL PHELPS CONSTRUCTION CO | B= | C | 04/05/2022 | All other required Final inspections are complete. (This is a computer generated result) | LONNYS | LONNYS | | B= | C | 7326242 |
HENSEL PHELPS CONSTRUCTION CO | B= | P | 02/18/2022 | building final OK pending other required inspections. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | LONNYS | LONNYS | | B= | P | 7275373 |
HENSEL PHELPS CONSTRUCTION CO | B= | P | 09/15/2021 | fire stop detail and verification of correction on file / pic of rated door on file / building final OK pending other required inspections. Additional Inspections Required (computer generated): ENCORE ELECTRIC, INC. Electrical Final Inspection is not Completed yet, MECH ONE, INC. Mechanical Final Inspection is not Completed yet. | LONNYS | LONNYS | | B= | P | 7107214 |
HENSEL PHELPS CONSTRUCTION CO | B= | P | 09/14/2021 | still no documents attached /Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://www.youtube.com/watch?v=QS0hdGSBA6o -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): ENCORE ELECTRIC, INC. Electrical Final Inspection is not Completed yet, MECH ONE, INC. Mechanical Final Inspection is not Completed yet. | LONNYS | LONNYS | | B= | P | 7105520 |
HENSEL PHELPS CONSTRUCTION CO | B= | R | 09/13/2021 | no images uploaded / no site visit needed per contractor. Additional Inspections Required (computer generated): ENCORE ELECTRIC, INC. Electrical Final Inspection is not Completed yet, MECH ONE, INC. Mechanical Final Inspection is not Completed yet. | LONNYS | LONNYS | | B= | R | 7104319 |
HENSEL PHELPS CONSTRUCTION CO | B= | P | 09/09/2021 | pending other required inspection / complete BFR / door not installed at supply room - need to verify rating / rest of building final OK -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): ENCORE ELECTRIC, INC. Electrical Final Inspection is not Completed yet, MECH ONE, INC. Mechanical Final Inspection is not Completed yet. | LONNYS | LONNYS | | B= | P | 7102197 |
HENSEL PHELPS CONSTRUCTION CO | BFR | P | 09/09/2021 | pending other required inspections / need to upload fire stop detail on site for ducts less than 12" in diameter - penetrations OK per detail / still need detail for humidifier penetration / rest of frame OK pending other inspections / gyp attachment verified | LONNYS | LONNYS | | BFR | P | 7102192 |
HENSEL PHELPS CONSTRUCTION CO | BSP | P | 09/09/2021 | Training with Lonny on duct penetrations through fire barriers -- Discussed Hilti listings and annular space allowed per listing | DAKOTAB | DAKOTAB | | BSP | P | 7102169 |
HENSEL PHELPS CONSTRUCTION CO | BSP | P | 09/08/2021 | above ceiling inspection pending other required inspections // still need to splice in design changes for rated assemblies / still need to provide fire stop details for 12" duct and 2 other mechanical penetrations in fire barrier / need to label rated walls stating wall type - currently only read (1 HOUR) / need to seal electric penetration in smoke barrier above door to hall / rest of above ceiling OK | LONNYS | LONNYS | | BSP | P | 7099549 |
HENSEL PHELPS CONSTRUCTION CO | BFR | P | 08/24/2021 | still need to attach mech permit / splice required for design changes for shaft and fire barrier listings to V455 and V489 - listings reviewed on site / provide firestop details for all penetrations in rated assemblies for next inspection / rest of frame OK pending other required inspections | LONNYS | LONNYS | | BFR | P | 7082762 |
HENSEL PHELPS CONSTRUCTION CO | BFR | R | 08/20/2021 | attach mech permit and complete rough / framing incomplete to underside of floor ceiling at corner of cleaning supply area next to door / observed several penetration in both 1 hour shaft wall and 1 hour fire barrier - provide fire stop details / observed american gyp on site - both shaft wall and fire barrier listing do not allow american / reviewed UL U419 and U415 with site rep / staff office light gauge steel framing and wall infill framing OK pending other required inspecitons | LONNYS | LONNYS | | BFR | R | 7079915 |
HENSEL PHELPS CONSTRUCTION CO | BFR | R | 08/06/2021 | inspection request called in for wrong permit | LONNYS | LONNYS | | BFR | R | 7063340 |
ENCORE ELECTRIC, INC. | E= | C | 10/13/2021 | Fire Alarm above ceiling of 6 devices OK. | AARONR | AARONR | | E= | C | 7140104 |
ENCORE ELECTRIC, INC. | E= | R | 09/13/2021 | Electrical OK. Complete final pending fire alarm. | AARONR | AARONR | | E= | R | 7104710 |
ENCORE ELECTRIC, INC. | ER | P | 09/08/2021 | above ceilings ok minus FA | RANDY | RANDY | | ER | P | 7100666 |
ENCORE ELECTRIC, INC. | EP | P | 09/08/2021 | no panels in this this inspection | RANDY | RANDY | | EP | P | 7100651 |
ENCORE ELECTRIC, INC. | E= | P | 08/30/2021 | phase 1 pod 23 only, electrically safe for move in | RANDY | RANDY | | E= | P | 7090784 |
ENCORE ELECTRIC, INC. | ER | P | 08/30/2021 | no rough | RANDY | RANDY | | ER | P | 7090775 |
ENCORE ELECTRIC, INC. | ER | P | 08/20/2021 | 3 walls rough OK. | AARONR | AARONR | | ER | P | 7080371 |
MECHONE, INC. | H= | C | 09/28/2021 | TEST AND BALANCE REPORT RECEIVED MECHANICAL FINAL COMPLETE | TREVORH | TREVORH | | H= | C | 7121875 |
MECHONE, INC. | HD | C | 09/08/2021 | PREVIOUSLY MENTIONED HUMIDIFIER PIPING AND CONTROLLER HAS BEEN TAKEN OFF LINE PIPING AND VALVE REMOVED FROM WALL . ALL DUCTING AND INSULATION COMPLETE, AT FINAL WILL NEED TO SEE THE TEST AND BALANCE REPORT. | TREVORH | TREVORH | | HD | C | 7100181 |
MECHONE, INC. | HD | P | 08/30/2021 | QUESTIONING HUMIDIFIER RELIEF CONTROLLER IS CURRENTLY HALF WAY IN THE NEW FIRE RATED WALL (FURTHER RESEARCH REQUIRED FOR THIS BREACH OF THE MEMBRANE) NEW BRANCH DUCTING RAN PER PLAN OK , OK TO WRAP, CLEAN SUPPLY ROOM WILL REQUIRE TO BE DUCTED TO THE REGISTER VERIFY AT NEXT INSPECTION. | TREVORH | TREVORH | | HD | P | 7090811 |
ENCORE ELECTRIC, INC. | XES | T | 10/04/2021 | PAID (REC#1812110): PLAN SPLICE FEE: $50 by: DANIELG for Electrical: Added sheet E302A. Smoke detectors. | DANIELG | DANIELG | | XES | T | 7128595 |
HENSEL PHELPS CONSTRUCTION CO | XBS | T | 09/27/2021 | PAID (REC#1810099): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Added scope of work. | MICHAELA | MICHAELA | | XBS | T | 7121191 |
HENSEL PHELPS CONSTRUCTION CO | XBS | T | 09/09/2021 | PAID (REC#1805389): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Change shaftwall assembly | MICHAELA | MICHAELA | | XBS | T | 7100757 |
HENSEL PHELPS CONSTRUCTION CO | XES | T | 08/13/2021 | PAID (REC#1798709): PLAN SPLICE FEE: $50 by: DANIELG for Electrical: Revised second floor lighting plan. As built. | DANIELG | DANIELG | | XES | T | 7072519 |