FIREPLACE WAREHOUSE | B= | C | 04/28/2022 | Items corrected | TRENTP | TRENTP | | B= | C | 7355710 |
FIREPLACE WAREHOUSE | B= | P | 04/28/2022 | Photos of corrections on file / Pending field inspection of items -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 7355339 |
FIREPLACE WAREHOUSE | BSP | P | 04/28/2022 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | BSP | P | 7355336 |
FIREPLACE WAREHOUSE | BSP | P | 04/28/2022 | Provide Test report for materials used for fire protection of floor per IRC 302.13 EX #4 / Installer certificate for product used for fire protection of floors on file | TRENTP | TRENTP | | BSP | P | 7355306 |
FIREPLACE WAREHOUSE | B= | P | 04/27/2022 | Provide product test report and installers certificate for material used in fire protection of floors per IRC 302.13 EX #4 / Missing weather protective covering for bases of front porch pillars / More than 30 inches of fall within 36 inches of rear deck stairs landing walking surface under deck / Will accept photos of corrections uploaded to inspection request / Finished basement, rear deck, w/stairs, AC -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 7354018 |
FIREPLACE WAREHOUSE | BIN | C | 04/27/2022 | Changed to BSP / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BIN | C | 7353682 |
NEW HAVEN HOMES | BLA | C | 03/15/2022 | | CHAD | CHAD | | BLA | C | 7302200 |
NEW HAVEN HOMES | BSP | P | 03/07/2022 | Training with Greg T -- Front porch post ok per letter on file | CHAD | CHAD | | BSP | P | 7292704 |
NEW HAVEN HOMES | BSP | C | 03/07/2022 | items completed - Training with Chad | GREGT | GREGT | | BSP | C | 7292695 |
NEW HAVEN HOMES | BSP | P | 02/18/2022 | Engineer letter for front porch posts on file, observed at previous inspection / Update by TP on 2/18/22, after further review still need to observe front porch posts as they have change / Contractor to request inspection when ready | TRENTP | TRENTP | | BSP | P | 7275382 |
NEW HAVEN HOMES | BIN | C | 01/28/2022 | Will inspect attic insulation at final / Need air leakage test results by final | TRENTP | TRENTP | | BIN | C | 7253921 |
NEW HAVEN HOMES | BFR | C | 01/28/2022 | Items corrected | TRENTP | TRENTP | | BFR | C | 7253918 |
NEW HAVEN HOMES | BFR | P | 01/28/2022 | Engineer letter on file for basement header changes / Pending inspection of HUS hanger fastener corrections | TRENTP | TRENTP | | BFR | P | 7253213 |
NEW HAVEN HOMES | BFR | P | 01/24/2022 | Still need to address fasteners in HUS hangers and replacement headers at both southern basement opening / Rest okay | TRENTP | TRENTP | | BFR | P | 7248281 |
NEW HAVEN HOMES | BSP | P | 01/24/2022 | Engineer letters for frame items and photo of over frame clips on file / Pending field inspection of other corrections | TRENTP | TRENTP | | BSP | P | 7247248 |
NEW HAVEN HOMES | BFR | T | 01/13/2022 | PAID (REC#1837288) Still need to inspect trusses, front porch posts, and rear deck frame at re inspection /// 1. Over notched top plate for AC lines at western garage wall / 2. Need clarification for use of steel post at front facing western garage door in place of trimmers per plan / 3. Need splice or provide licensed design professional clarification for added western garage door, secure bottom of post /4. Need clarification for use of shims throughout garage sill plates / 5. Incorrect fasteners used in HUS hangers in garage / 6. Unable to confirm VCTR clips at garage over framing / 7. Missing fireblocking of low volt wires throughout house / 8. Over drilled studs at Eastern great room bearing wall / 9. Need to clear trash and combustibles from fireplace chase / 10. Missing MTS12 at southern bearing point for TR71 / 11. Missing bearing block and HTS20 at interior bearing point for TR71 / 12. Roof not dried in at master bathroom fan vents / 13. Missing H2.5 at eastern bearing point fo | TRENTP | TRENTP | | BFR | T | 7238413 |
NEW HAVEN HOMES | BSP | P | 01/05/2022 | Front porch lid ok, still need to inspect posts / Rear porch lid and posts ok, still need to inspect rear deck frame / | ERIKK | ERIKK | | BSP | P | 7229188 |
NEW HAVEN HOMES | BSP | P | 01/05/2022 | Engineer letter for porch post and caps on file / | ERIKK | ERIKK | | BSP | P | 7228515 |
NEW HAVEN HOMES | BSP | P | 12/07/2021 | Inspection for front piers only / Front piers and re enforcement okay | TRENTP | TRENTP | | BSP | P | 7199826 |
NEW HAVEN HOMES | BSP | R | 12/03/2021 | Front cover piers missing re enforcement per updated pier layout on file, pier dimensions match layout / Rear deck pier at south east corner not shown on foundation design or update pier layout, observed 22x30in pier without re enforcement | TRENTP | TRENTP | | BSP | R | 7196889 |
NEW HAVEN HOMES | BFD | C | 12/03/2021 | Engineer letter for perimeter drain on file -- Damp proofing noted / | TRENTP | TRENTP | | BFD | C | 7196357 |
NEW HAVEN HOMES | BFN | C | 12/03/2021 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 7196355 |
NEW HAVEN HOMES | BFT | C | 12/03/2021 | open hole on file -- 2000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | TRENTP | TRENTP | | BFT | C | 7196354 |
NEW HAVEN HOMES | BSP | P | 12/02/2021 | Engineer detail on file to changed to foundation design on file / Still need to complete other foundation inspection | TRENTP | TRENTP | | BSP | P | 7194543 |
NEW HAVEN HOMES | BFI | C | 09/27/2021 | R10 installed / Note: Need to complete BFT, BFN, and BFD | TRENTP | TRENTP | | BFI | C | 7120665 |
CO ENERGY ELECTRIC LLC | E= | C | 04/22/2022 | | TOMC | TOMC | | E= | C | 7349399 |
CO ENERGY ELECTRIC LLC | E= | R | 04/21/2022 | need gfi protection on well circuit , dryer circuit , disconnect needs emergency disconnect / service disconnect label ----- 20 amp a/c , 30 amp a/c , GFCI protection of A/C unit not required due to variance granted by the State Electrical Board 9/29/2021. / | TOMC | TOMC | | E= | R | 7348049 |
CO ENERGY ELECTRIC LLC | EUG | C | 01/12/2022 | 250 urd | TOMC | TOMC | | EUG | C | 7237370 |
CO ENERGY ELECTRIC LLC | ES | C | 01/12/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 7237369 |
CO ENERGY ELECTRIC LLC | ER | C | 01/12/2022 | 1 - # 1 AL , 9 - # 10 , irreversible ufer , no mcc , no central vac , finished basement , | TOMC | TOMC | | ER | C | 7237365 |
CO ENERGY ELECTRIC LLC | ER | R | 01/10/2022 | install nail plates, nm not centered on studs (1 1/4 spacing ) nm cable stapled on edge, smoke and co outlet box located to close to wall at hall and bedroom by kitchen ufer not made, nm cable wrapped around gas pipe at entry to u finished area complete re-inspect | BRET | BRET | | ER | R | 7234391 |
TOM JOHNSON, INC. | H= | C | 04/20/2022 | Whole house ventilation being achieved with exhaust fan located in laundry room. / Whole house ventilation switch located in laundry room / NOTE / FINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN X2 / DIRECT VENT FURNACE X2/ A/C COMPLETE X2/ HIGH/LOW GRILLS INTO MECHANICAL ROOM / | JHORSMAN | JHORSMAN | | H= | C | 7345534 |
TOM JOHNSON, INC. | HC | C | 01/07/2022 | RELEASE METER | JHORSMAN | JHORSMAN | | HC | C | 7231653 |
TOM JOHNSON, INC. | HRR | C | 01/07/2022 | BASEMENT DRYER INSTRUCTIONS RECEIVED, SEE IMAGES/ PER DRYER INSTRUCTIONS PROVIDE, DRYER DUCT WITH 4 90'S CAN EXHAUST 60 FEET/ BY FINAL LABEL DRYER EXHAUST DUCT PER IRC M1502.4.6/ AT FINAL IF INSTALLED VERIFY DRYER INSTALLED | JHORSMAN | JHORSMAN | | HRR | C | 7231652 |
TOM JOHNSON, INC. | HRR | P | 01/06/2022 | BASEMENT DRYER EXHAUST DUCT TO TERMINATE AT EXTERIOR/ IN CURRENT CONFIGURATION BASEMENT DRYER EXHAUST DUCT EXCEEDS ALLOWED LENGTH PER IRC M1502.4.5.1// A/C LINESETS WERE UNDER PRESSURE AT TIME OF INSPECTION, 445 LB TEST OK Whole house ventilation being achieved with exhaust fan located in laundry room. / Verify whole house ventilation switch location at final / NOTE / FINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN X2/ DIRECT VENT FURNACE X2/ A/C ROUGH, COIL AND LINESET X2/ | JHORSMAN | JHORSMAN | | HRR | P | 7231167 |
SPRINGS GAS, INC. | HI | C | 12/29/2021 | 3/4 STUB ON THE DECK IS GOOD FOR UP TO 50K BTUS/ STUB IN THE GARAGE IS GOOD FOR UP TO 80K BTUS | JHORSMAN | JHORSMAN | | HI | C | 7223876 |
SPRINGS GAS, INC. | HI | P | 12/28/2021 | WHAT WERE THE BTUS USED TO CALCULATE THE 3/4 STUB ON THE DECK, AND THE 3/4 STUB IN THE GARAGE?/
10 LB TEST OK / 1 1/2 INCH MAIN / 2 FURNACES / 2 WATER HEATERS / 1 RANGE / 1 FIREPLACE / ONE 3/4 INCH STUB ON THE DECK/ ONE 3/4 INCH STUB IN THE GARAGE | JHORSMAN | JHORSMAN | | HI | P | 7221913 |
FIREPLACE WAREHOUSE | HV | C | 12/07/2021 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / | JHORSMAN | JHORSMAN | | HV | C | 7200177 |
MD SERVICE PLUMBING, INC. | P= | C | 04/21/2022 | | TREBORB | TREBORB | | P= | C | 7347230 |
MD SERVICE PLUMBING, INC. | P= | P | 04/21/2022 | POTABLE WATER CERT ATTACHED | TREBORB | TREBORB | | P= | P | 7346470 |
MD SERVICE PLUMBING, INC. | P= | P | 04/19/2022 | NEED POTABLE WATER CERT UPLOADED TO NEXT INSPECTION REQUEST; LEAK ON PRESSURE TANK AT WELL RISER; REST OK NOTE: FINISHED BASEMENT; 3/4" RPZ FOR IRRIGATION | TREBORB | TREBORB | | P= | P | 7343750 |
NEW HAVEN HOMES | PWO | C | 03/15/2022 | need certificate of potable water by final. | TAYLOR | TAYLOR | | PWO | C | 7302136 |
MD SERVICE PLUMBING, INC. | PTO | C | 12/29/2021 | | TAYLOR | TAYLOR | | PTO | C | 7224246 |
MD SERVICE PLUMBING, INC. | PTO | P | 12/28/2021 | low test H2O, rest ok, finished basement, VTR x 3, aav's at bar sink and all basement lavs, CWV at laundry sink, check water service connections by final. | TAYLOR | TAYLOR | | PTO | P | 7222252 |
MD SERVICE PLUMBING, INC. | PB | C | 10/01/2021 | NOTE/ O.K. | CODYP | CODYP | | PB | C | 7127507 |
MD SERVICE PLUMBING, INC. | PB | P | 09/30/2021 | TWO TRAPS ON THE SAME TRAP ARM IN BATHROOM, NOTE/ Clean out at South East 3" stack/ Clean out at West 3" stack | CODYP | CODYP | | PB | P | 7125573 |