HOMEOWNER | B= | P | 04/24/2024 | Open hole report on file. Additional Inspections Required (computer generated): NATIVE ELECTRIC Electrical Final Inspection is not Completed yet. | GREGT | GREGT | | B= | P | 8063379 |
HOMEOWNER | B= | P | 02/29/2024 | Need to provide open hole report. Additional Inspections Required (computer generated): NATIVE ELECTRIC Electrical Final Inspection is not Completed yet. | GREGT | GREGT | | B= | P | 8009506 |
HOMEOWNER | BSP | P | 02/29/2024 | Soils report on file | GREGT | GREGT | | BSP | P | 8009496 |
HOMEOWNER | BSP | R | 02/27/2024 | No documents uploaded with request / No inspection / | ERIKK | ERIKK | | BSP | R | 8007360 |
HOMEOWNER | B= | P | 12/01/2023 | Complete other inspection finals / Building final okay pending upload of open hole report. Additional Inspections Required (computer generated): NATIVE ELECTRIC Electrical Final Inspection is not Completed yet. | GREGT | GREGT | | B= | P | 7932849 |
HOMEOWNER | BFR | P | 12/01/2023 | Frame okay pending upload of open hole report | GREGT | GREGT | | BFR | P | 7932844 |
HOMEOWNER | BFR | P | 12/01/2023 | | ERIKK | ERIKK | | BFR | P | 7932505 |
HOMEOWNER | BSP | P | 12/01/2023 | Engineer letter on file for beam splice observation / | ERIKK | ERIKK | | BSP | P | 7932504 |
HOMEOWNER | BFN | P | 12/01/2023 | Still need open hole report and soils letter uploaded / Engineer letter for foundation on file / | ERIKK | ERIKK | | BFN | P | 7932503 |
HOMEOWNER | BFT | P | 12/01/2023 | Still need open hole report and soils letter uploaded / Engineer letter for footing on file / | ERIKK | ERIKK | | BFT | P | 7932502 |
HOMEOWNER | BSP | R | 11/30/2023 | Need to upload open hole letter, soils report, footing and foundation observations, drain observations if required, per previous inspectors notes from 3-11-22 prior to calling final inspection / Still need to complete missing beam splice detail per 10/S102 , or need engineer letter approving, per inspectors notes from 4/4/22 / | ERIKK | ERIKK | | BSP | R | 7931278 |
HOMEOWNER | BFR | R | 03/22/2023 | cancelled by homeowner | LONNYS | LONNYS | | BFR | R | 7694329 |
HOMEOWNER | BFR | R | 03/21/2023 | plumbing pictures to be uploaded to plumbing permit / mech inspection to be requested for mech permit by mech cnotractor | LONNYS | LONNYS | | BFR | R | 7692892 |
HOMEOWNER | BSP | R | 10/05/2022 | ER inspection to be requested under electric permit | LONNYS | LONNYS | | BSP | R | 7539934 |
HOMEOWNER | BFR | P | 09/08/2022 | Need roof dried in / Rest of new garage frame ok / | ERIKK | ERIKK | | BFR | P | 7510551 |
HOMEOWNER | BFR | P | 06/07/2022 | interior and exterior wall framing at old garage OK pending other required inspections | LONNYS | LONNYS | | BFR | P | 7401869 |
HOMEOWNER | BIN | C | 06/07/2022 | UPDATE: UPON FURTHER INSPECTION // R-30 used in old garage floors / remainder of insulation for scope of project OK pedning other required inspections | LONNYS | LONNYS | | BIN | C | 7401866 |
HOMEOWNER | BIN | P | 06/03/2022 | Old garage floor at R-19 | RYANF | RYANF | | BIN | P | 7398679 |
HOMEOWNER | BSP | R | 06/03/2022 | Nothing attached to inspection | DAKOTAB | DAKOTAB | | BSP | R | 7398189 |
HOMEOWNER | BIN | R | 06/02/2022 | Not ready for insulation on old garage floor and exterior wall framing / | ERIKK | ERIKK | | BIN | R | 7396859 |
HOMEOWNER | BFR | P | 06/02/2022 | Still need open hole and foundation observation uploaded / Floor framing in old garage ok / | ERIKK | ERIKK | | BFR | P | 7396858 |
HOMEOWNER | BFR | P | 04/27/2022 | rear deck frame inspection / still need to inspect landing when ready / rest of deck frame and posts OK pending footing observation for deck | LONNYS | LONNYS | | BFR | P | 7354689 |
HOMEOWNER | BFR | P | 04/04/2022 | complete all foundation inspections noted below / deck frame not ready - fastening and hardware incomplete - needs complete reinspection / main floor framing at recessed shower OK / missing beam splice detail per 10/S102 / NOTE: still need to inspect main floor framing at entrance and stair framing when ready | LONNYS | LONNYS | | BFR | P | 7324672 |
HOMEOWNER | BIN | P | 03/16/2022 | pending splices and reinspection for basement beam - rear addition wall insulation OK only | LONNYS | LONNYS | | BIN | P | 7303317 |
HOMEOWNER | BFR | R | 03/11/2022 | provide open hole, footing and foundation obs., foundation insulation obs, new foundation deisgn and perimeter drain obs. if required in open hole / need to splice in all new main level floor framing changes plus garage remodel and have inspected / main level framing for addition and remodel OK / still need to inspect new beam in basement once splice is approved / still need to inspect deck / reviewed smokes and COs with HO | LONNYS | LONNYS | | BFR | R | 7298238 |
HOMEOWNER | BTR | C | 02/01/2022 | BTR OK - Rear 1/3 of house | JASONB | JASONB | | BTR | C | 7257761 |
OC ELECTRIC LLC | E= | C | 06/06/2023 | | RANDY | RANDY | | E= | C | 7764217 |
OC ELECTRIC LLC | E= | P | 06/05/2023 | walked with owner and only saw afci breakers and no gfci? | RANDY | RANDY | | E= | P | 7762139 |
OC ELECTRIC LLC | E= | R | 03/21/2023 | New installed bsmt receptacles will need AF/GF/TR protection / Bsmt outside back up high under deck - Exposed NM cables | BRETC | BRETC | | E= | R | 7693470 |
NATIVE ELECTRIC | E= | R | 10/14/2022 | will need gfci protection on all new outlets in basement | RANDY | RANDY | | E= | R | 7551167 |
OC ELECTRIC LLC | ER | C | 10/06/2022 | spoke with contractor about corrections----check on final | RANDY | RANDY | | ER | C | 7542394 |
NATIVE ELECTRIC | ER | P | 04/22/2022 | office area and hall ok laundry not ready ( garage conversion ) and receptacle to center basement column and to wall backing mech room | BRET | BRET | | ER | P | 7348966 |
NATIVE ELECTRIC | ER | P | 03/10/2022 | main floor only--- master/ kitchen/dining/living -----re-attach box in dining that was removed for framing ------- per Bret F | MATTHEW | MATTHEW | | ER | P | 7297197 |
MECHANICAL SYSTEMS OF COLORADO. CORP | H= | C | 03/23/2023 | NOTE / LOUVER DOOR / | MATTM | MATTM | | H= | C | 7696205 |
MECHANICAL SYSTEMS OF COLORADO. CORP | HSP | P | 03/22/2023 | ***ATTENTION CONTRACTOR***UPDATE YOUR SCOPE OF WORK. SEE NOTES LISTED ON 10/25/22 / | MATTM | MATTM | | HSP | P | 7694291 |
FIREPLACE WAREHOUSE | H= | C | 01/06/2023 | Gas shutoff in lower portion of fireplace, see images / Heat final for fireplace only / | CASEYM | CASEYM | | H= | C | 7627214 |
FIREPLACE WAREHOUSE | H= | P | 01/05/2023 | Unable to locate gas shutoff valve for fireplace, contractor to verify location / Ok to send pictures with next inspection request / | CASEYM | CASEYM | | H= | P | 7626222 |
MECHANICAL SYSTEMS OF COLORADO. CORP | HSP | P | 10/31/2022 | Update 10/31/22 WH: Following review with plumbing inspector, condensate drains serving ceiling cassette mini-splits may not be tied into to sanitary waste vent within attic. Condensate drains must terminate in an approved location. Service access for cassettes through face-plate per manufacturers installation instructions. Still need to see remaining corrections from H= on 10/25/22. | WHITNEYH | WHITNEYH | | HSP | P | 7566942 |
MECHANICAL SYSTEMS OF COLORADO. CORP | H= | P | 10/25/2022 | CONTRACTOR TO ADD THE FOLLOWING ITEMS TO SCOPE OF WORK: 3 BATHROOM EXHAUSTS / 1 RANGE EXHAUST / 1 DRYER EXHAUST / 1 CONDENSING UNIT / FURNACE VERIFIED AS EXISTING MATCHING EQUIPMENT FORM SUBMITTED TO PLAN REVIEW / WATER HEATER VENT DISCONNECTED TO ACCOMMODATE INSTALLATION OF NEW PLUMBING DRAIN LINE IN MECHANICAL ROOM - NEED TO ACHIEVE MINIMUM 1 INCH CLEARANCE TO COMBUSTIBLES FROM BVENT / MECHANICAL ROOM LACKS COMBUSTION AIR AS PRE-EXISTING HIGH/LOWS WERE COVERED / SECURE MINI-SPLIT CONDENSING UNIT TO APPLIANCE PAD PER MANUFACTURERS REQUIREMENTS / CONTINUE LINE-SET INSULATION FLUSH TO CASSETTE BODY IN ATTIC / FURTHER REVIEW WITH PLUMBING INSPECTOR ON CONDENSATE TIE IN TO SANITARY DRAIN VENT IN ATTIC / REVIEW OF SERVICE ACCESS REQUIREMENTS FOR CASSETTE UNITS REQUIRED- WILL UPDATE NOTES / NOTE / FINISHED BASEMENT / PRE-EXISTING OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE - LACKING COMBUSTION AIR FOR 36K BTU WATER HEATER X2 / | WHITNEYH | WHITNEYH | | H= | P | 7561724 |
FIREPLACE WAREHOUSE | HV | C | 07/07/2022 | Drywall installed prior to HV inspection / Was able to verify clearances through pictures provided on site by contractor as well as scope through upper access in chase / Main level fireplace clearance to combustibles and vent termination ok / | CASEYM | CASEYM | | HV | C | 7437596 |
MECHANICAL SYSTEMS OF COLORADO. CORP | HRR | P | 03/10/2022 | CONTRACTOR TO CONTACT BUILDER TO DETERMINE WHAT ALL WORK IS BEING DONE IN ORDER TO ACCURATELY UPDATE SCOPE OF WORK TO INCLUDE 2 EXHAUST FANS, 1 FURNACE, DUCT WORK, AND WATER HEATER VENTING, POSSIBLY MORE/ FIREPLACE VENTING IN GREAT ROOM IS INSTALLED WITH OPEN FIREPLACE PERMIT, FIREPLACE PERMIT TO BE MERGED WITH BUILDING PERMIT. WILL NEED FIREPLACE INSTALLED AND INSPECTION CALLED. IF FIREPLACE IS NOT BEING INSTALLED VENTING TO BE CAPPED OR REMOVED/ BATHROOM EXHAUST OK. MAX CFM ALLOWED ON FANS IS 50 CFM, VERIFY 50 CFM FANS AT FINAL/ Note to building inspector. Master bedroom and bathroom ok for mechanical. Contractors expressed a request to start making the rooms habitable again. Master bedroom and bathroom ok, great room still needs confirmation on the fireplace. | JHORSMAN | JHORSMAN | | HRR | P | 7297004 |
FIREPLACE WAREHOUSE | HSP | P | 03/09/2022 | If the fireplace is being re-installed during the remodel of the address, this permit needs to be merged with the building permit N71205. There is venting installed, but appears that there will also need framing around the fireplace. | JHORSMAN | JHORSMAN | | HSP | P | 7401263 |
MECHANICAL SYSTEMS OF COLORADO. CORP | HRR | P | 03/09/2022 | ELECTRICAL CONTRACTOR TO ATTACH TO PERMIT/ CONTRACTOR TO CONTACT BUILDER TO DETERMINE WHAT ALL MECHANICAL WORK IS BEING DONE TO UPDATE SCOPE OF WORK. CURRENTLY 2 EXHAUST FANS, RESIDENTIAL DUCT, AND FURNACE NEED TO BE ADDED/ WILL NEED EQUIPMENT CERTIFICATE, DUCT DESIGN, AND LOAD CALS SUBMITTED TO PLAN REVIEW FOR NEW FURNACE SYSTEM BEING INSTALLED IN ADDITION/ IF THE WATER HEATER VENTING IS BEING MODIFIED AND CONFIGURATION CHANGED, THE WATER HEATER VENTING WILL NEED TO BE ADDED TO SCOPE OF WORK/ MAIN LEVEL EXHAUST FANS TO TERMINATE TO THE EXTERIOR. CURRENT FANS ARE 50/80/110 CFM FANS WITH 4 INCH HARD PIPE CONNECTING TO THE FANS. IN THE CURRENT PIPE CONFIGURATION FANS CAN ONLY BE SET TO 50 CFM/ NOTE/ FINISHED BASEMENT/ PRE-EXISTING OUTSIDE AIR TO FURNACE RETURN/ DIRECT VENT FURNACE/ HIGH/LOW GRILLS INTO MECHANICAL ROOM | JHORSMAN | JHORSMAN | | HRR | P | 7295992 |
FIREPLACE WAREHOUSE | HE | P | 01/25/2022 | | NICKYA | NICKYA | | HE | P | 7401262 |
AIM'S PLUMBING LLC | P= | C | 03/21/2023 | see images / ok | TREBORB | TREBORB | | P= | C | 7693037 |
AIM'S PLUMBING LLC | P= | P | 10/25/2022 | CAP UNUSED LAUNDRY DRAIN, LAUNDRY DRAIN IS ROUGH ONLY ; NEED PROPER AIR GAP FOR STEAM UNIT BLOWDOWN | TREBORB | TREBORB | | P= | P | 7562296 |
AIM'S PLUMBING LLC | PTO | P | 04/22/2022 | LAUNDRY SINK TRAP ARM AND WATER INCOMPLETE; REST OK ; OK TO FLOW TEST TRAP ARM ON LAUNDRY; POWDER BATH OK; WASHER BOX OK; MASTER BATH OK; (NO WORK DONE ON BASMENT BATHROOMS X2); MIX VALVE FOR MASTER TUB IN MECH ROOM; STILL NEED TO ADD WATER HEATERS TO PERMIT, LOOK AT WATER HEATERS AT FINAL; SEE PRVIOUS PTO NOTES | TREBORB | TREBORB | | PTO | P | 7349818 |
AIM'S PLUMBING LLC | PTO | P | 03/09/2022 | Need electrical attached to permit, provide listing number for master shower and master toilet, leak at master shower valve, missing nail protection at left master lav vent and master shower vent, NOTE/ LOOKED AT MAIN HOUSE MASTER BATHROOM AND KITCHEN ONLY/ WATER HEATERS MOVING IN MECH ROOM WILL NEED TO BE INSPECTED AND ADDED TO PERMIT/ AAV @ Kitchen sink/ 2-VTR | CODYP | CODYP | | PTO | P | 7296001 |
MECHANICAL SYSTEMS OF COLORADO. CORP | XMS | P | 05/31/2022 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical | JUSTINC | JUSTINC | | XMS | P | 7393374 |
HOMEOWNER | XBS | T | 04/05/2022 | PAID (REC#1860616): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Additional scope of work at basement - updated scope throughout | MICHAELA | MICHAELA | | XBS | T | 7325891 |