IRON LEGACY HOMES LLC. | B= | C | 03/10/2022 | Installers certificate and evaluation report for thermal barrier on file | TRENTP | TRENTP | | B= | C | 7296702 |
IRON LEGACY HOMES LLC. | B= | P | 03/08/2022 | Need to provide installers certificate and evaluation report for alternative thermal barrier used to protect spray foam insulation, discussed with contractor over phone / Splice on file for updated interior walls -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 7293454 |
IRON LEGACY HOMES LLC. | B= | P | 02/07/2022 | need to revise design to reflect as-built condition - to reflect additional interior walls completed / updated 2/7/21 - missing thermal barrier at exposed foam -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 7261451 |
IRON LEGACY HOMES LLC. | BSP | P | 01/04/2022 | Lean to roof rafter hanger corrections OK | JASONB | JASONB | | BSP | P | 7228109 |
IRON LEGACY HOMES LLC. | BSP | P | 01/04/2022 | Engineered detail for rafter notch and hangers at lean to roof on file | JASONB | JASONB | | BSP | P | 7227262 |
IRON LEGACY HOMES LLC. | BFN | C | 01/04/2022 | footing depth verified for lean to portion | LONNYS | LONNYS | | BFN | C | 7227233 |
IRON LEGACY HOMES LLC. | BFN | P | 01/03/2022 | Inspection request for picture upload -- No picture attached | CHAD | CHAD | | BFN | P | 7226008 |
IRON LEGACY HOMES LLC. | BSP | R | 12/30/2021 | Need to complete BFT for lean to addition portion splice / Rafter hardware not per plan / Rest of frame is OK / OK to insulate as long as corrected hardware can be observed | JASONB | JASONB | | BSP | R | 7224946 |
IRON LEGACY HOMES LLC. | BFR | C | 10/11/2021 | | CHRISTYB | CHRISTYB | | BFR | C | 7137778 |
IRON LEGACY HOMES LLC. | BFT | C | 10/06/2021 | Pier footings are ok and per plan / | ERIKK | ERIKK | | BFT | C | 7132677 |
CENTENNIAL STATE ELECTRIC | E= | C | 02/04/2022 | | TOMC | TOMC | | E= | C | 7259777 |
CENTENNIAL STATE ELECTRIC | EUG | C | 12/28/2021 | 2" pvc ok to back fill | BRET | BRET | | EUG | C | 7221556 |
CENTENNIAL STATE ELECTRIC | EP | R | 12/28/2021 | install 150 amp breaker in tap conductors only 2/0 or you may replace conductors with 4/0 | BRET | BRET | | EP | R | 7221553 |
CENTENNIAL STATE ELECTRIC | ER | C | 12/28/2021 | | BRET | BRET | | ER | C | 7221535 |
ROCKY MOUNTAIN MECHANICAL, LLC | H= | C | 02/07/2022 | RECEIVED APPROVAL FROM BLACK HILLS ENERGY FOR MEDIUM PRESSURE GAS SYSTEM | ANGELW | ANGELW | | H= | C | 7260994 |
ROCKY MOUNTAIN MECHANICAL, LLC | HI | C | 12/30/2021 | APPROVAL LETTER FROM BLACK HILLS ENERGY FOR MEDIUM PRESSURE GAS SYSTEM REQUIRED BY FINAL / 10 LB TEST ON 20 FEET 1/2 INCH BLACK PIPE FROM RISER OFF UNDERGROUND LINE TO GARAGE HEATER OK / MEDIUM PRESSURE LABELING IN PLACE / | ANGELW | ANGELW | | HI | C | 7225176 |
ROCKY MOUNTAIN MECHANICAL, LLC | HRR | C | 12/30/2021 | APPROVAL LETTER FROM BLACK HILLS ENERGY FOR MEDIUM PRESSURE GAS SYSTEM REQUIRED BY FINAL / GARAGE HEATER INSTALLATION, CLEARANCES TO COMBUSTIBLES VENT AND VENT TERMINATION OK / | ANGELW | ANGELW | | HRR | C | 7225166 |
ROCKY MOUNTAIN MECHANICAL, LLC | H= | P | 12/29/2021 | MECHANICAL FINAL PENDING APPROVAL LETTER FROM BLACK HILLS ENERGY FOR MEDIUM PRESSURE GAS SYSTEM AND CONTRACTOR WHO IS INSTALLING THE GARAGE HEATER TO EITHER ADD TO PERMIT OR, IF CONTRACTOR IS ALREADY LISTED, ADD GARAGE HEATER TO THEIR SCOPE OF WORK / IECC FORMS ARE NOT REQUIRED AS THERE IS NO HABITABLE SPACE / | ANGELW | ANGELW | | H= | P | 7223024 |
ROCKY MOUNTAIN MECHANICAL, LLC | H= | P | 12/28/2021 | FINAL PENDING APPROVAL LETTER FROM BLACK HILLS ENERGY FOR MEDIUM PRESSURE GAS SYSTEM AND VERIFICATION OF IECC REQUIREMENTS FOR DETACHED GARAGE HEATER / | ANGELW | ANGELW | | H= | P | 7221651 |
ROCKY MOUNTAIN MECHANICAL, LLC | HC | C | 12/28/2021 | RELEASE METER FOR UPGRADE TO MEDIUM PRESSURE GAS SYSTEM | ANGELW | ANGELW | | HC | C | 7221647 |
ROCKY MOUNTAIN MECHANICAL, LLC | HO | C | 12/28/2021 | *REQUIRED BY FINAL: APPROVAL LETTER FROM BLACK HILLS ENERGY FOR MEDIUM PRESSURE GAS SYSTEM* 10 LB TEST ON 130 FEET 3/4 INCH PE WITH TRACER WIRE FROM RISER AT HOUSE TO DETACHED GARAGE FOR GARAGE HEATER OK / OK TO COVER / | ANGELW | ANGELW | | HO | C | 7221643 |
IRON LEGACY HOMES LLC. | XBS | T | 03/07/2022 | PAID (REC#1848701): PLAN SPLICE FEE: $50 by: DANM for Construction: 2 interior walls add in lean-to portion of detached garage | DANM | DANM | | XBS | T | 7292439 |
IRON LEGACY HOMES LLC. | XBS | T | 11/16/2021 | PAID (REC#1825231): PLAN SPLICE FEE: $50 by: DANM for Construction: 960 sf lean-to addition added to scope of work | DANM | DANM | | XBS | T | 7178077 |