ELDER CONSTRUCTION, INC. | B= | C | 09/14/2023 | All other required Final inspections are complete. (This is a computer generated result) | CHAD | CHAD | | B= | C | 7856452 |
ELDER CONSTRUCTION, INC. | B= | P | 08/11/2023 | Crawl space -- No deck. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yetRequest inspection through PPRBD system or contact 719-385-5982 for zoning questions, External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | CHAD | CHAD | | B= | P | 7823825 |
ELDER CONSTRUCTION, INC. | B= | P | 08/11/2023 | blower door on file/ building final inspection required -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yetRequest inspection through PPRBD system or contact 719-385-5982 for zoning questions, External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection UBS by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection UWS by CSUREVIEW is not Completed yet (Contact: 668-3524). | SHAUN | SHAUN | | B= | P | 7823681 |
ELDER CONSTRUCTION, INC. | BSP | P | 04/20/2023 | attic insulation ok | SHAUN | SHAUN | | BSP | P | 7722076 |
ELDER CONSTRUCTION, INC. | BFR | C | 11/21/2022 | | ERIKK | ERIKK | | BFR | C | 7588507 |
ELDER CONSTRUCTION, INC. | BFN | C | 11/21/2022 | | ERIKK | ERIKK | | BFN | C | 7588506 |
ELDER CONSTRUCTION, INC. | BFT | C | 11/21/2022 | open hole on file -- 3,000 PSF -- slab-- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | ERIKK | ERIKK | | BFT | C | 7588505 |
ELDER CONSTRUCTION, INC. | BFN | R | 10/27/2022 | Compaction testing logs not required for foundation inspections - Need Open hole report | CHRISTINEH | CHRISTINEH | | BFN | R | 7564118 |
ELDER CONSTRUCTION, INC. | BFN | P | 10/26/2022 | Soils report on file / Need open hole report / 3000# | CHRISTINEH | CHRISTINEH | | BFN | P | 7562512 |
ELDER CONSTRUCTION, INC. | BIN | P | 10/25/2022 | Need to complete BFT/BFN - Observed wall insulation ok / Can verify blocking in crawlspace at final - Rest of BFR ok | CHRISTINEH | CHRISTINEH | | BIN | P | 7561488 |
ELDER CONSTRUCTION, INC. | BFN | P | 10/25/2022 | See BFT | CHRISTINEH | CHRISTINEH | | BFN | P | 7560890 |
ELDER CONSTRUCTION, INC. | BFT | P | 10/25/2022 | Need original Soils report and Open hole / Foundation design in plans - 3000# / Footing and foundation observations file | CHRISTINEH | CHRISTINEH | | BFT | P | 7560887 |
ELDER CONSTRUCTION, INC. | BFR | R | 10/24/2022 | No documentation attached | CHRISTINEH | CHRISTINEH | | BFR | R | 7559545 |
ELDER CONSTRUCTION, INC. | BFR | P | 10/21/2022 | Still need 3rd party observations for foundations | JEREMYA | JEREMYA | | BFR | P | 7558194 |
ELDER CONSTRUCTION, INC. | BFR | P | 10/20/2022 | Complete all third party paperwork | JEREMYA | JEREMYA | | BFR | P | 7556647 |
ELDER CONSTRUCTION, INC. | BSP | P | 08/23/2022 | Fire rated assembly ok / Exterior sheathing and straps ok | CHRISTINEH | CHRISTINEH | | BSP | P | 7492671 |
WINTERS ELECTRIC, INC. | E= | C | 04/07/2023 | P-tac---5500 watt water heater | JIMMY | JIMMY | | E= | C | 7709944 |
WINTERS ELECTRIC, INC. | EP | C | 11/11/2022 | 101 and 102 --- 125 amp EM /Service disconnect - ok Check labeling on final | JIMMY | JIMMY | | EP | C | 7580968 |
WINTERS ELECTRIC, INC. | ER | C | 10/04/2022 | 101 and 102 ok-- 10/2--- 10/3--8/3--12 to heater-- Irreversible UFER connection / No Cent Vac / No jet tub installed / | JIMMY | JIMMY | | ER | C | 7539018 |
CBA MECHANICAL LLC | H= | C | 06/26/2023 | CONDENSATE OK DRYER ELECTRIC NO MAKE UP AIR REQUIRED | NICKE | NICKE | | H= | C | 7781516 |
CBA MECHANICAL LLC | H= | P | 05/24/2023 | NEED PTAC INSTRUCTIONS TO VERIFY CONDENSATE DRAIN. PROVIDE 100SQ INCHES OF MAKEUP AIR FOR LAUNDRY ROOM. NOTE / CONDITIONED CRAWL SPACE / Whole house ventilation switch located in bathroom / Whole house ventilation being achieved through exhaust fan located in bathroom / PTAC | NICKE | NICKE | | H= | P | 7753392 |
CBA MECHANICAL LLC | H= | P | 11/10/2022 | THIS INSPECTION FOR CRAWLSPACE VENTILATION EXHAUST FAN IN UNITS 101 AND 102. PIPING IN WALL OK TO DRYWALL / | NICKE | NICKE | | H= | P | 7578966 |
CBA MECHANICAL LLC | HI | C | 10/19/2022 | NO GAS INSTALLED AT THIS HOUSE. COMPLETED HI INSPECTION SO BFR CAN BE REQUESTED WHEN READY / | NICKE | NICKE | | HI | C | 7555572 |
CBA MECHANICAL LLC | HRR | C | 10/19/2022 | BDA PG 233 SHOWS NEW DETAIL FOR CRAWL SPACE VENTILATION AND FAN. NEED UPDATED IECC FORM TO SHOW WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH BATHROOM EXHAUST FAN. PTAC UNITS NOT INSTALLED AT INSPECTION VERIFY CONDENSATE DRAIN AT FINAL / Whole house ventilation being achieved through exhaust fan located in bathroom. / Verify whole house ventilation switch location at final / NOTE PTAC UNITS | NICKE | NICKE | | HRR | C | 7555558 |
CBA MECHANICAL LLC | HRR | P | 09/30/2022 | CONTRACTOR TO ADDRESS THE CRAWLSPACE VENTILATION EXHAUST FAN INSTALLATION. APPROVED PLANS CALL FOR THE IN-LINE FAN TO EXHAUST TO THE EXTERIOR VIA THE ROOF (SEE BDA PAGE #214, PLAN PAGE M502 DETAIL #1.) THIS FAN IS ALSO THE WHOLE HOUSE VENTILATION FAN AS PER THE VENTILATION FORM ON BDA PAGE #209. FAN IS CURRENTLY JUST RECYCLING THE CRAWLSPACE AIR TO THE LIVING SPACE. DRYER EXHAUST AND BATHROOM EXHAUST BOTH OK. | BILLS | BILLS | | HRR | P | 7535726 |
SOCO PLUMBING | P= | C | 08/10/2023 | NOTE/ Crawlspace x2/ No Irrigation/ Electric water heater x2 | CODYP | CODYP | | P= | C | 7822969 |
SOCO PLUMBING | PTO | C | 10/04/2022 | NOTE/ Crawlspace x2/ No Irrigation/ 2-VTR/ Check water heaters at final | CODYP | CODYP | | PTO | C | 7539258 |
ELDER CONSTRUCTION, INC. | XMS | T | 11/03/2022 | PAID (REC#1912364): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: Approved:This building has un-vented crawl space with fan and transfer grill per the 2015 IRC section R408.3 using 2.1. See the crawlspace plan | TCRIPPEN | TCRIPPEN | | XMS | T | 7572000 |
ELDER CONSTRUCTION, INC. | XBS | T | 10/14/2022 | PAID (REC#1907680): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Fire rated details. | SHELLEY | SHELLEY | | XBS | T | 7551056 |
ELDER CONSTRUCTION, INC. | XES | P | 10/11/2022 | PLAN SPLICE: (No Fee) by: BERTHA for Electrical: Disconnects must be grouped. | BERTHA | BERTHA | | XES | P | 7547195 |
ELDER CONSTRUCTION, INC. | XPS | P | 10/11/2022 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Plumbing: electric water heater. | TCRIPPEN | TCRIPPEN | | XPS | P | 7546760 |
ELDER CONSTRUCTION, INC. | XMS | P | 10/11/2022 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Mechanical: New splice for crawlspace exhaust fan | TCRIPPEN | TCRIPPEN | | XMS | P | 7546755 |
ELDER CONSTRUCTION, INC. | XBS | T | 07/19/2022 | PAID (REC#1891644): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Alternate ASW listing | SHELLEY | SHELLEY | | XBS | T | 7450974 |
ELDER CONSTRUCTION, INC. | XMS | P | 06/14/2022 | PLAN SPLICE: (No Fee) by: TCRIPPEN for Mechanical: This building has unvented crawl space with fan and transfer grill per the 2015 IRC section R408.3 using 2.1. See the crawlspace plan | TCRIPPEN | TCRIPPEN | | XMS | P | 7410749 |
ELDER CONSTRUCTION, INC. | XBS | T | 06/14/2022 | PAID (REC#1891644): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Convert from modular to site built | SHELLEY | SHELLEY | | XBS | T | 7410392 |
ELDER CONSTRUCTION, INC. | XES | P | 04/22/2022 | PLAN SPLICE: (No Fee) by: RICHG for Electrical: Disconnects must be grouped | RICHG | RICHG | | XES | P | 7348742 |