PRO WALL SYSTEMS LLC | B= | C | 04/12/2022 | All other required Final inspections are complete. (This is a computer generated result) | DAKOTAB | DAKOTAB | | B= | C | 7334432 |
PRO WALL SYSTEMS LLC | B= | P | 04/04/2022 | Items corrected. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | DAKOTAB | DAKOTAB | | B= | P | 7324818 |
PRO WALL SYSTEMS LLC | B= | L | 03/25/2022 | Front door locked -- Left voicemail with call ahead number. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | DAKOTAB | DAKOTAB | | B= | L | 7315436 |
PRO WALL SYSTEMS LLC | B= | P | 03/02/2022 | Temp CO: Pending F=, H=, H=, B= ( Expires: 4/1/2022 12:00:00 AM) | BRITNEY | BRITNEY | | B= | P | 7288298 |
PRO WALL SYSTEMS LLC | B= | P | 02/11/2022 | Missing knee protection at drain under sink in bathroom -- Need to complete other finals -- Training with Erik K. -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), MICK HEATING & SHEET METAL CO. Mechanical Final Inspection is not Completed yet, CLEAR WATER PLUMBING, HEATING & UTILITIE Plumbing Final Inspection is not Completed yet. | DAKOTAB | DAKOTAB | | B= | P | 7267785 |
PRO WALL SYSTEMS LLC | BSP | P | 02/11/2022 | Final inspection training with Dakota / ANSI standards / | ERIKK | ERIKK | | BSP | P | 7267679 |
PRO WALL SYSTEMS LLC | BFR | P | 12/02/2021 | Need to attach mechanical and have inspections -- Interior light gauge frame OK pending other roughs -- Reviewed Accessible Elements | DAKOTAB | DAKOTAB | | BFR | P | 7195926 |
MEYER ELECTRIC | E= | C | 02/10/2022 | | BRET | BRET | | E= | C | 7266599 |
MEYER ELECTRIC | E= | P | 02/09/2022 | install gfci breaker for refrigerator receptacle within 6' of sink , install aic label on panel | BRET | BRET | | E= | P | 7264488 |
MEYER ELECTRIC | ES | C | 01/03/2022 | Commercial Service: 200 amp service for unit 174, contractor to change brass tag and re label breaker prior to csu arrival | BRET | BRET | | ES | C | 7227092 |
MEYER ELECTRIC | ER | P | 12/01/2021 | walls ok | RANDY | RANDY | | ER | P | 7193566 |
MICK HEATING & SHEET METAL CO. | H= | C | 03/23/2022 | TEST AND BALANCE REPORT RECEIVED MECHANICAL FINAL COMPLETE | TREVORH | TREVORH | | H= | C | 7311005 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | H= | C | 03/17/2022 | 2 PSIG APPROVAL ON FILE GAS FINAL COMPLETE. | TREVORH | TREVORH | | H= | C | 7304701 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | H= | P | 03/01/2022 | GAS FINAL PENDING------------NEED LETTER FROM GAS PURVEYOR APPROVING THE 2 PSIG SYSTEM. | TREVORH | TREVORH | | H= | P | 7286375 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | HC | C | 02/15/2022 | RELEASE 2 PSIG METER | TREVORH | TREVORH | | HC | C | 7271596 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | HI | P | 02/15/2022 | NEED PLAN SPLICE OMITTING THE GAS LINE TO THE WATER HEATER, 10 LB TEST OK FOR METER RELEASE.. | TREVORH | TREVORH | | HI | P | 7271587 |
MICK HEATING & SHEET METAL CO. | H= | P | 02/14/2022 | MECHANICAL FINAL PENDING--------------PLAN SPLICE, TEST AND BALANCE REPORT, NO ON SITE INSPECTION NEEDED. | TREVORH | TREVORH | | H= | P | 7269370 |
MICK HEATING & SHEET METAL CO. | H= | P | 02/10/2022 | FORTHCOMING PLAN SPLICE SEE IMAGES. MECHANICAL FINAL PENDING -------------TEST AND BALANCE REPORT, APPROVED PLAN, AND VERIFICATION OF CONTROLS/REMOTE INDICATOR | TREVORH | TREVORH | | H= | P | 7265857 |
MICK HEATING & SHEET METAL CO. | HD | P | 02/04/2022 | WILL NEED A GAS CONTRACTOR ATTACHED TO THE PERMIT, SHEET M1.1 IS SHOWING THE EXISTING RTU-14 AS A 5 TON UNIT, 7.5 TON CURRENTLY INSTALLED WILL NEED UPDATED APPROVED PLAN WITH NEW SCHEDULE, THE 7.5 TON UNIT WILL BE OVER 2000 CFM WILL NEED TO SEE A DUCT DETECTOR INSTALLED WITH AN AUDIBLE AND VISUAL REMOTE INDICATOR. DUCT ROUGH COMPLETE DUCT RAN PER PLAN, EXHAUST DUCTING COMPLETE, THERMOSTAT PER PLAN. NO ROOF TODAY DUE TO | TREVORH | TREVORH | | HD | P | 7260181 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | P= | C | 03/01/2022 | | CODYP | CODYP | | P= | C | 7286200 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | P= | P | 02/22/2022 | Sink drain capped see images, Still need splice | CODYP | CODYP | | P= | P | 7277172 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | P= | P | 02/15/2022 | CAP SINK DRAIN, OK TO ATTACH PHOTO AT NEXT INSPECTION REQUEST, STILL NEED SPLICE FOR REMOVED SINK AND AAV, NOTE/ Rest o.k. | CODYP | CODYP | | P= | P | 7271268 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | P= | P | 02/14/2022 | STILL NEED SPLICE ON AAV AND SINK REMOVED, T & P LACKS PROPER AIR GAP, NOTE/ Rest o.k. | CODYP | CODYP | | P= | P | 7269628 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | PTO | P | 01/10/2022 | NEED 16-18" OFF OF SIDE WALL TO CENTER OF TOILET, PARTIAL PENDING SPLICE FOR SINK BEING REMOVED AND AAV, NOTE/ Rest o.k. | CODYP | CODYP | | PTO | P | 7234251 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | PB | C | 11/02/2021 | | CODYP | CODYP | | PB | C | 7163051 |
MICK HEATING & SHEET METAL CO. | XMS | T | 03/09/2022 | PAID (REC#1849398): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Layout and schedule revisions | JUSTINC | JUSTINC | | XMS | T | 7296412 |
CLEAR WATER PLUMBING, HEATING & UTILITIES, LLC | XPS | T | 02/28/2022 | PAID (REC#1846942): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 2 revisions: Adjusted sheet P0.1. | SHANEN | SHANEN | | XPS | T | 7284520 |