MOUNTAIN WEST CONTRACTORS, LLC | B= | C | 05/11/2022 | All other required Final inspections are complete. (This is a computer generated result) | BRIANB | BRIANB | | B= | C | 7372550 |
MOUNTAIN WEST CONTRACTORS, LLC | B= | P | 05/02/2022 | pending other final inspections. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | BRIANB | BRIANB | | B= | P | 7360021 |
MOUNTAIN WEST CONTRACTORS, LLC | BFR | P | 02/03/2022 | observed light gauge wall framing / need to attach mechanical to permit and complete other rough inspections | BRIANB | BRIANB | | BFR | P | 7259401 |
TEK ELECTRICAL SERVICES, LLC | ER | C | 04/27/2022 | Rough ok / | ROB | ROB | | ER | C | 7354165 |
TEK ELECTRICAL SERVICES, LLC | E= | C | 04/27/2022 | Electrical ok / | ROB | ROB | | E= | C | 7354156 |
TEK ELECTRICAL SERVICES, LLC | E= | R | 03/10/2022 | See ER comments / | ROB | ROB | | E= | R | 7297763 |
TEK ELECTRICAL SERVICES, LLC | ER | P | 03/10/2022 | Need GFCI protection for dryer / All new breakers need to be 22k / Support all 2x4 fixtures / Support cable in Break Area ceiling / Need blank on box in ceiling above panel area / | ROB | ROB | | ER | P | 7297762 |
TEK ELECTRICAL SERVICES, LLC | ER | P | 02/03/2022 | Rough ok for walls / Discussed ANSI requirement -- NPT, Transition Fittings, 22k breakers for panel / | ROB | ROB | | ER | P | 7259160 |
A & H MECHANICAL, INC. | H= | C | 04/12/2022 | TAB REPORT FOR EXHAUST FAN RECEIVED - SEE IMAGES | JERRYF | JERRYF | | H= | C | 7334395 |
A & H MECHANICAL, INC. | H= | P | 04/08/2022 | NEED TAB REPORT ON COMPANY LETTER HEAD | JERRYF | JERRYF | | H= | P | 7330938 |
A & H MECHANICAL, INC. | H= | P | 03/21/2022 | NEED TAB REPORT ON COMPANY LETTER HEAD NOTE / PICTURES OF SLEEVED DRYER DUCT RECEIVED / | JERRYF | JERRYF | | H= | P | 7307711 |
A & H MECHANICAL, INC. | H= | P | 03/16/2022 | PARTIAL PENDING TAB REPORT AND PICTURES OF DRYER VENT SLEEVE IN RETURN AIR PLENUM | JERRYF | JERRYF | | H= | P | 7304083 |
A & H MECHANICAL, INC. | HD | P | 03/16/2022 | NEED TO SLEEVE DRYER VENT (OK TO ATTACH PICTURES TO TAB REPORT) | JERRYF | JERRYF | | HD | P | 7304082 |
SPARROW ENTERPRISES, INC. | P= | C | 04/15/2022 | corrections made | ANTHONYT | ANTHONYT | | P= | C | 7340362 |
SPARROW ENTERPRISES, INC. | P= | P | 03/23/2022 | need mixing valves installed at shampoo bowls and need trap guard installed at floor drain / rest ok | ANTHONYT | ANTHONYT | | P= | P | 7311664 |
SPARROW ENTERPRISES, INC. | P= | P | 03/11/2022 | CUSTOMER EXPLAINED THAT THEY REMOVED EXISTING LAVATORY AND INSTALLED A NON-ADA/ANSIA117.1 COMPLIANT LAVATORY SINK IN EXISTING BATHROOM; NEED TO RE-INSTALL COMPLIANT SINK / NEED TO COMPLETE INSTALL OF FLOOR DRAIN; WILL NEED TRAP GUARD/ SHAMPOO BOWLS ARE S-TRAP, ;SHAMPOO BOWLS REQUIRE A MIXING VALVE; REST OK | TREBORB | TREBORB | | P= | P | 7298313 |
SPARROW ENTERPRISES, INC. | PTO | C | 01/31/2022 | | TREBORB | TREBORB | | PTO | C | 7255545 |
SPARROW ENTERPRISES, INC. | PTO | P | 01/25/2022 | SECURE AND PROTECT PEX PIPING IN WALL AND OVERHEAD, PROTECT THRU METAL STUDS; NEED BOCA PLATE FOR 2" DWV; REST OK; COMPLETED PB INSPECTION NOTE: AAV IN CEILING ABOVE SHAMPOO SINK | TREBORB | TREBORB | | PTO | P | 7249497 |
SPARROW ENTERPRISES, INC. | PB | C | 01/25/2022 | OK | TREBORB | TREBORB | | PB | C | 7249493 |
TEK ELECTRICAL SERVICES, LLC | XES | T | 04/07/2022 | PAID (REC#1860815): PLAN SPLICE FEE: $50 by: DANIELG for Electrical: Revised SCA/AIC for panel TP4. | DANIELG | DANIELG | | XES | T | 7329631 |