HOMEOWNER | B= | C | 03/21/2024 | All other required Final inspections are complete. (This is a computer generated result) | TRENTP | TRENTP | | B= | C | 8028843 |
HOMEOWNER | B= | P | 02/28/2024 | Items corrected. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 8008802 |
HOMEOWNER | BSP | P | 02/26/2024 | Air Leakage Testing Per 2015 IECC Section R402.4.1.2 on file | TRENTP | TRENTP | | BSP | P | 8005469 |
HOMEOWNER | B= | R | 02/23/2024 | 1. Missing code compliant address numbers on house / 2. Missing 36 inch landing at front door, ramp currently present does not meet code / 3. Missing 36 inch landing at south exterior door, height greater than 30 inches from grade / 4. Missing guard and graspable hand rail and south stairs / 5. Basement handrail does not start or end at nose of top and bottom risers / 6. Exposed foam plastics exposed throughout basement / 7. Need to complete siding under roof eves / 8. Need to seal all penetrations in siding around all elevations // Unfinished basement, no deck, no AC. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 8004694 |
HOMEOWNER | BIN | C | 08/02/2023 | Installer certificate and insulation data sheet received on site / Need air leakage test results by final, will inspect basement insulation at final | TRENTP | TRENTP | | BIN | C | 7814943 |
HOMEOWNER | BSP | R | 08/02/2023 | Insulation certificate provided is incomplete, discussed certificate requirements with homeowner over phone | TRENTP | TRENTP | | BSP | R | 7814667 |
HOMEOWNER | BFR | C | 07/13/2023 | Items corrected / Discussed insulation, air barrier, and air leakage test requirements with homeowner | TRENTP | TRENTP | | BFR | C | 7796951 |
HOMEOWNER | BFR | R | 07/11/2023 | Incomplete fastening in all hardware throughout house, inspector reviewed manufactures requirements with homeowners onsite / Incomplete fireblocking throughout multiple locations in house, discussed fireblocking requirements with homeowners / Need to tie interrupted top plates at all 4 corners of house exterior walls / Unfinished basement, no deck | TRENTP | TRENTP | | BFR | R | 7794786 |
HOMEOWNER | BE | P | 01/30/2023 | | JACKIEP | JACKIEP | | BE | P | 7648244 |
HOMEOWNER | BFD | C | 07/20/2022 | Drain around entire to daylight at northwest, dampproofing okay / Drain ok / Contractor to backfill per requirements of Soils Report / | TRENTP | TRENTP | | BFD | C | 7452842 |
HOMEOWNER | BFN | C | 07/05/2022 | Foundation forms and re enforcement okay per foundation design on file / Eufer observed | TRENTP | TRENTP | | BFN | C | 7434489 |
HOMEOWNER | BFT | C | 06/22/2022 | Footing and interior pad forms and re enforcement okay per foundation design on file | TRENTP | TRENTP | | BFT | C | 7420573 |
HOMEOWNER | BFT | R | 06/21/2022 | Footing form widths at east and west sides and interior pads incomplete at time of inspection | TRENTP | TRENTP | | BFT | R | 7418688 |
HOMEOWNER | BFT | P | 06/21/2022 | Foundation Design on file / 1500 psf verified / UPDATE: June 22 by Paul P -- Upon Further Review, / soils on file | PAULP | PAULP | | BFT | P | 7418296 |
HOMEOWNER | BFT | P | 06/21/2022 | open hole on file -- 1500 PSF -- usable -- 10% / NEED footing and foundation observation / foundation design on file (bearing capacity verified) / | PAULP | PAULP | | BFT | P | 7418287 |
HOMEOWNER | BE | P | 06/01/2022 | | JACKIEP | JACKIEP | | BE | P | 7395291 |
HOMEOWNER | E= | C | 11/17/2023 | | RANDY | RANDY | | E= | C | 7921869 |
HOMEOWNER | ES | C | 11/17/2023 | Residential Underground: 150-amp 3-wire service upgrade, no action required by utility. / | TOMC | TOMC | | ES | C | 7921756 |
HOMEOWNER | E= | P | 11/10/2023 | ADD OUTLET AT FRONT OF HOUSE ----- PROTECT N/M CABLE SEVERAL LOCATIONS -----REST OK ---- NO A/C ----- | GREGM | GREGM | | E= | P | 7914929 |
HOMEOWNER | EP | C | 11/10/2023 | EP OK ----- | GREGM | GREGM | | EP | C | 7914928 |
HOMEOWNER | ER | C | 06/12/2023 | / 125-amp 3-wire service upgrade, no action required by utility. / Discussed AFCI/GFCI/TR requirements with owner. / | TOMC | TOMC | | ER | C | 7768837 |
HOMEOWNER | EUG | C | 04/03/2023 | EUG OK ------ 2" PVC ONLY ------- | GREGM | GREGM | | EUG | C | 7705157 |
HOMEOWNER | H= | C | 11/10/2023 | Corrections made, verified via images provided by text from homeowner / | CASEYM | CASEYM | | H= | C | 7915544 |
HOMEOWNER | H= | P | 11/10/2023 | Pressure relief valve for boiler needs to be piped to floor (1 1/2-6" above floor) / Install 90 elbow and screen on boiler intake pipe termination / Ok to send pictures / Whole house ventilation being achieved through exhaust fan located in bathroom / Whole house ventilation switch located in bathroom / NOTE / Unfinished basement / Direct vent boiler with sidearm / No A/C / | CASEYM | CASEYM | | H= | P | 7914975 |
HOMEOWNER | HRR | C | 07/10/2023 | Whole house fan and vent installed. | SAMS | SAMS | | HRR | C | 7793745 |
HOMEOWNER | HRP | C | 07/10/2023 | 60 lb test ok for main and upper floors, ok to cover / | SAMS | SAMS | | HRP | C | 7793172 |
HOMEOWNER | HRR | P | 07/10/2023 | Install the whole house ventilation fan / Boiler venting ok, no terminations installed at this time /// Per conversation with homeowners no range or dryer duct being installed at this time /// | SAMS | SAMS | | HRR | P | 7793162 |
HOMEOWNER | HC | C | 06/07/2023 | OK TO RELEASE METER | WHITNEYH | WHITNEYH | | HC | C | 7764753 |
HOMEOWNER | HO | C | 06/01/2023 | 10 lb test ok / | SAMS | SAMS | | HO | C | 7759958 |
HOMEOWNER | HI | C | 06/01/2023 | 10 LB TEST OK / | SAMS | SAMS | | HI | C | 7759934 |
HOMEOWNER | HO | P | 05/19/2023 | Underground gas line needs to be on pressure test / 25' of 1" PE with tracer wire from meter location to house / | CASEYM | CASEYM | | HO | P | 7749246 |
HOMEOWNER | HI | P | 05/19/2023 | Gas piping system needs to be on pressure test / 1 inch main / 1 Boiler / 1 Range / 1 Dryer / 3 tees in basement, two for alternate locations for future oven, one for future bbq / | CASEYM | CASEYM | | HI | P | 7749245 |
HOMEOWNER | P= | C | 02/23/2024 | Water cert uploaded to images | ADRIANM | ADRIANM | | P= | C | 8003886 |
HOMEOWNER | P= | P | 11/17/2023 | Pending water test / Rest OK / Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | ADRIANM | ADRIANM | | P= | P | 7922731 |
HOMEOWNER | P= | R | 11/10/2023 | remove cap from roof vent, undersized common vent at kitchen, need air gap at dishwasher drain, install mixing valve/ backflow protection at tub, crossed water lines at kitchen, need certificate of potable water, re- inspect all. | TAYLOR | TAYLOR | | P= | R | 7915312 |
HOMEOWNER | PTO | C | 06/16/2023 | AAV AT KITCHEN -- TWO VTR | LEE | LEE | | PTO | C | 7773967 |
HOMEOWNER | PTO | P | 06/13/2023 | SIDE ARM FOR DOMESTIC -- NEED TO SUPPORT W-BOX VENT AND MISC. PIPING IN BASEMENT TO CODE -- KITCHEN DRAIN LACKS PROPER GRADE -- LEAK AT EJECTOR 90 -- LEAK AT TUB TRAP -- NEED TO INSULATE 3/4" HOT DOMESTIC PIPING -- OTHER OK | LEE | LEE | | PTO | P | 7770154 |
HOMEOWNER | PWO | C | 06/01/2023 | EXISTING WELL HEAD -- INSPECTED FROM PIT TO HOUSE ON PB INSPECTION -- WILL NEED POTABLE H20 CERT BY FINAL | LEE | LEE | | PWO | C | 7759889 |
HOMEOWNER | PB | C | 08/09/2022 | FOR ONE K-CITY DRAIN ON EJECTOR -- WATER THRU WALL FROM EQUIPMENT VAULT -- NEED PWO | LEE | LEE | | PB | C | 7475749 |
HOMEOWNER | PB | P | 08/08/2022 | EJECTOR -- FLOOR DRAIN NOT VENTED TO CODE -- NO TEST -- PIPE NOT BEDDED IN -- NO ONE ON SITE | LEE | LEE | | PB | P | 7474422 |
HOMEOWNER | XBS | T | 02/27/2024 | PAID (REC#2037583) PLAN SPLICE FEE: $50 by: BPHILLIPS for Construction: Revised IECC compliance to performance method | BPHILLIPS | BPHILLIPS | | XBS | T | 8007213 |
HOMEOWNER | XMS | P | 09/01/2023 | PLAN SPLICE: (No Fee) by: RICHG for Mechanical: REVISED RES-CHECK. | RICHG | RICHG | | XMS | P | 7845804 |
HOMEOWNER | XBS | T | 07/10/2023 | PAID (REC#1968119) PLAN SPLICE FEE: $50 by: CHRISTINEH for Construction: Interior non load bearing wall changes / Window size changes - No header changes | CHRISTINEH | CHRISTINEH | | XBS | T | 7793859 |