MASTER BILT HOMES, INC. | B= | C | 06/20/2022 | | BRIANB | BRIANB | | B= | C | 7417200 |
MASTER BILT HOMES, INC. | BSP | P | 06/15/2022 | envelope leakage test report on file | BRIANB | BRIANB | | BSP | P | 7412822 |
MASTER BILT HOMES, INC. | B= | P | 06/15/2022 | missing batt insulation at unit separation wall in lower attic space / need air leakage test report -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 7412119 |
MASTER BILT HOMES, INC. | BLA | C | 05/02/2022 | | JASONL | JASONL | | BLA | C | 7360061 |
MASTER BILT HOMES, INC. | BSP | P | 04/22/2022 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | JASONL | JASONL | | BSP | P | 7348255 |
MASTER BILT HOMES, INC. | BIN | C | 04/21/2022 | Need to inspect attic insulation and blanket insulation in basement at final / Reviewed Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | JASONL | JASONL | | BIN | C | 7348023 |
MASTER BILT HOMES, INC. | BFR | C | 04/19/2022 | Unfinished basement / No deck / Observed front porch post and lid at frame | JASONL | JASONL | | BFR | C | 7344414 |
MASTER BILT HOMES, INC. | BFD | C | 02/10/2022 | Drain is entire to sump pit -- Damp proofing okay | BRIANB | BRIANB | | BFD | C | 7266544 |
MASTER BILT HOMES, INC. | BFN | C | 02/10/2022 | Soils report on file / Open hole on file / Drilled pier observation on file / Foundation wall observation on file, UFER noted / Foundation design on file / Drain required around entire structure per open hole on file -- 5% | JASONL | JASONL | | BFN | C | 7265844 |
MASTER BILT HOMES, INC. | BFT | C | 02/10/2022 | Soils report on file / Open hole on file / Drilled pier observation on file / Foundation wall observation on file, UFER noted / Foundation design on file / Drain required around entire structure per open hole on file -- 5% | JASONL | JASONL | | BFT | C | 7265842 |
MASTER BILT HOMES, INC. | BFT | P | 12/09/2021 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 7203516 |
MASTER BILT HOMES, INC. | BFN | P | 12/09/2021 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 7203515 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 06/08/2022 | Corrections completed from 6.2.2022 inspection/ | ROB | ROB | | E= | C | 7404117 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 06/02/2022 | CKT. 12 breaker won't test / Label Aprilaire disconnect and provide test light in receptacle / Need finished grade at Meter / Please have house numbers up in the future / | ROB | ROB | | E= | R | 7397483 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 04/15/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | ROB | ROB | | ES | C | 7340513 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 04/15/2022 | #14 CU to Refer / Irreversible UFER connection / Unfinished Basement / | ROB | ROB | | ER | C | 7340500 |
OAK VIEW INVESTMENTS, LLC | H= | C | 06/08/2022 | Whole house ventilation being achieved with dampered outside air duct to furnace return. / Whole house ventilation switch located at furnace / NOTE / Unfinished basement / No A/C / Outside air with damper to furnace return / Direct vent furnace / | JONH | JONH | | H= | C | 7404320 |
OAK VIEW INVESTMENTS, LLC | H= | P | 06/06/2022 | Support furnace venting every 4' per pg. 46 in the installation instructions / Ok to send pictures (with clear measurements) with next inspection request / Whole house ventilation being achieved with dampered outside air duct to furnace return. / Whole house ventilation switch located at furnace / NOTE / Unfinished basement / No A/C / Outside air with damper to furnace return / Direct vent furnace / | CASEYM | CASEYM | | H= | P | 7400177 |
OAK VIEW INVESTMENTS, LLC | HC | C | 04/18/2022 | RELEASE METER | JONH | JONH | | HC | C | 7342134 |
OAK VIEW INVESTMENTS, LLC | HRR | C | 04/18/2022 | Whole house ventilation being achieved with dampered outside air duct to furnace return. / Verify whole house ventilation switch location at final / Note / Unfinished basement / Direct vent furnace / Outside air with damper to furnace return / | JONH | JONH | | HRR | C | 7342111 |
OAK VIEW INVESTMENTS, LLC | HRR | P | 04/15/2022 | 1st 90 elbow on combustion intake furnace is not glued properly. 2nd 90 elbow on combustion air on intake is not seated correctly on pipe. Where combustion air intake pipe connects to concentric vent termination, does not have proper slope.(trapped) Whole house ventilation being achieved with dampered outside air duct to furnace return. / Verify whole house ventilation switch location at final / Note / Unfinished basement / Direct vent furnace / Outside air with damper to furnace return / | JONH | JONH | | HRR | P | 7341078 |
SPRINGS GAS, INC. | HI | C | 04/12/2022 | 10 LB TEST OK / 1 INCH MAIN / 1 FURNACE / 1 WATER HEATER / 1 RANGE / | JONH | JONH | | HI | C | 7335830 |
JOLLY PLUMBING & HEATING INC. | P= | C | 06/03/2022 | ok note: no irrigation | ANTHONYT | ANTHONYT | | P= | C | 7399218 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 04/05/2022 | ok note: 1 vtr / aav at all lavs and at fd in basement / no irrigation / unfinished basement | ANTHONYT | ANTHONYT | | PTO | C | 7326747 |
JOLLY PLUMBING & HEATING INC. | PB | C | 02/22/2022 | CHECK VENT AND AAV FOR FLOOR DRAIN AT PTO; CO ON ALL RISERS | TREBORB | TREBORB | | PB | C | 7278603 |