MASTER BILT HOMES, INC. | B= | C | 08/17/2022 | unfinished basement / no deck | BRIANB | BRIANB | | B= | C | 7486256 |
MASTER BILT HOMES, INC. | BSP | P | 08/05/2022 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | JASONL | JASONL | | BSP | P | 7472380 |
MASTER BILT HOMES, INC. | BLA | C | 06/15/2022 | updated 17AUG22 - note - verified 5/8" x gyp at exterior side of exterior rated wall assembly | BRIANB | BRIANB | | BLA | C | 7412030 |
MASTER BILT HOMES, INC. | BIN | C | 06/03/2022 | Observed insulation installed per REScheck on file / Observed insulation installed at protection wall in attic at separation wall per GA file WP3514 / Air Leakage Testing Requirements Per 2015 IECC Section R402.4.1.2 to be Provided by Final Inspection / | JUSTINL | JUSTINL | | BIN | C | 7398739 |
MASTER BILT HOMES, INC. | BFR | C | 06/03/2022 | Observed landing framing per letter on file | JUSTINL | JUSTINL | | BFR | C | 7398732 |
MASTER BILT HOMES, INC. | BSP | P | 06/03/2022 | letter for stair landing framing details on file | JASONL | JASONL | | BSP | P | 7398002 |
MASTER BILT HOMES, INC. | BFR | P | 06/01/2022 | unable to locate landing framing details in approved design, need to provide framing details and field inspect stair landing / Unfinished basement / Observed framing for exterior wall rated assembly second level GA file no. WP 3514 | JASONL | JASONL | | BFR | P | 7396049 |
MASTER BILT HOMES, INC. | BSP | P | 04/27/2022 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | JASONL | JASONL | | BSP | P | 7353485 |
MASTER BILT HOMES, INC. | BFD | C | 02/10/2022 | Drain is entire to sump pit -- Damp proofing okay | BRIANB | BRIANB | | BFD | C | 7266498 |
MASTER BILT HOMES, INC. | BFN | C | 02/10/2022 | Soils report on file / Open hole on file / Drilled pier observation on file / Foundation wall observation on file, UFER noted / Foundation design on file / Drain required around entire structure per open hole on file -- 5% | JASONL | JASONL | | BFN | C | 7265809 |
MASTER BILT HOMES, INC. | BFT | C | 02/10/2022 | Soils report on file / Open hole on file / Drilled pier observation on file / Foundation wall observation on file, UFER noted / Foundation design on file / Drain required around entire structure per open hole on file -- 5% | JASONL | JASONL | | BFT | C | 7265807 |
MASTER BILT HOMES, INC. | BFT | P | 12/09/2021 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 7203547 |
MASTER BILT HOMES, INC. | BFN | P | 12/09/2021 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 7203546 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 07/21/2022 | Electrical ok / | ROB | ROB | | E= | C | 7455167 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 05/24/2022 | Rough ok / Correction from 5.23.2022 inspection complete / | ROB | ROB | | ER | C | 7387620 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 05/23/2022 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / Irreversible UFER connection / | CHIPO | CHIPO | | ES | C | 7386099 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | R | 05/23/2022 | Interior front entry light need switch leg stubbed into box (just left hanging near by) - all else okay - #10 CU to dryer / no MCCs / no cen vac / unfinished basement | CHIPO | CHIPO | | ER | R | 7386098 |
OAK VIEW INVESTMENTS, LLC | H= | C | 08/10/2022 | CORRECTION MADE, SEE IMAGES | JONH | JONH | | H= | C | 7477267 |
OAK VIEW INVESTMENTS, LLC | H= | P | 08/03/2022 | gas line no longer properly supported in basement. re-support all gas piping. OK TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST / WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / WHOLE HOUSE VENTILATION SWITCH LOCATED AT FURNACE / NOTE / UNFINISHED BASEMENT / DIRECT VENT FURNACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / | JONH | JONH | | H= | P | 7469406 |
OAK VIEW INVESTMENTS, LLC | HC | C | 05/26/2022 | RELEASE METER | JONH | JONH | | HC | C | 7390575 |
OAK VIEW INVESTMENTS, LLC | HRR | C | 05/26/2022 | WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / UNFINISHED BASEMENT / DIRECT VENT FURNACE / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / NO A/C / | JONH | JONH | | HRR | C | 7390563 |
OAK VIEW INVESTMENTS, LLC | HRR | P | 05/24/2022 | M1506.3 IN THE IRC STATES NO EXHAUST TERMINATIONS ARE TO BE WITHIN 3' OF THE PROPERTY LINE(PARTY WALL) THIS IS AFFECTING BOTH UNITS/ B-VENT LACKS 1" CLEARANCE TO COMBUSTIBLES ON AT MAIN LEVEL TOP PLATE. WHOLE HOUSE VENTILATION BEING ACHIEVED WITH DAMPERED OUTSIDE AIR DUCT TO FURNACE RETURN. / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / UNFINISHED BASEMENT / DIRECT VENT FURNACE WITH COMBUSTION AIR FROM ATTIC / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / NO A/C / | JONH | JONH | | HRR | P | 7387262 |
SPRINGS GAS, INC. | HI | C | 05/20/2022 | | JONH | JONH | | HI | C | 7384153 |
SPRINGS GAS, INC. | HI | P | 05/18/2022 | PROPERLY SUPPORT MAIN AS IT ENTERS THE HOME. INCREASE HEIGHT AND SUPPORT GAS RANGE STUB SO IT INS NOT RESTING ON THE GAS SHUT OFF. 10 LB TEST OK / 1 INCH MAIN / 1 FURNACE / 1 WATER HEATER / 1 RANGE / | JONH | JONH | | HI | P | 7380478 |
JOLLY PLUMBING & HEATING INC. | P= | C | 07/22/2022 | ok note: no PVB | ANTHONYT | ANTHONYT | | P= | C | 7456969 |
JOLLY PLUMBING & HEATING INC. | PTO+ | C | 05/20/2022 | Ok for re-pipe in master bath. Note: AAV both lavs. | DANR | DANR | | PTO+ | C | 7383973 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 05/12/2022 | ok note: 2 vtr / aav at floor drain and up hall full bath / no irrigation / unfinished basement | ANTHONYT | ANTHONYT | | PTO | C | 7373703 |
JOLLY PLUMBING & HEATING INC. | PB | C | 03/01/2022 | CORRECTIONS MADE, AAV AT FLOOR DRAIN | TREBORB | TREBORB | | PB | C | 7286721 |
JOLLY PLUMBING & HEATING INC. | PB | R | 02/28/2022 | NEED VENT FOR FLOOR DRAIN; REST OK EXPLAINED VENTING REQUIREMENT TO INSTALLER AT PREVIOUS BASE INSPECTIONS, NONE OF THE FLOOR DRAINS HAVE PROPER VENTING | TREBORB | TREBORB | | PB | R | 7284155 |