WOOD STONE CONSTRUCTION, LLC. | B= | C | 07/11/2022 | Corrections completed | JUSTINL | JUSTINL | | B= | C | 7441995 |
WOOD STONE CONSTRUCTION, LLC. | B= | P | 07/07/2022 | Temp CO: Pending B= ( Expires: 8/6/2022 12:00:00 AM) | BRITNEY | BRITNEY | | B= | P | 7438121 |
WOOD STONE CONSTRUCTION, LLC. | B= | P | 07/01/2022 | Door hardware inside of unit does not comply with operable parts of 2009 ANSI section 309 - twist locks at all hardware on doors inside of unit / Observed remaining final inspection elements and accessible elements pending other final inspections including core and shell -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): GREATHOUSE AND SPEER PLUMBING AND HEATIN Mechanical Final Inspection is not Completed yet. | JUSTINL | JUSTINL | | B= | P | 7434061 |
WOOD STONE CONSTRUCTION, LLC. | BSP | P | 06/23/2022 | incorrect inspection requested - courtesy inspection requested for accessible elements / reviewed accessible elements wit Ken from Woodstone / changed inspection from final to BSP | BRIANB | BRIANB | | BSP | P | 7422459 |
WOOD STONE CONSTRUCTION, LLC. | BFR | P | 04/13/2022 | observed interior light gauge wall framing / pending other rough inspections including for core and shell permit / reviewed accessible elements with Ken | BRIANB | BRIANB | | BFR | P | 7337307 |
WOOD STONE CONSTRUCTION, LLC. | BIN | P | 04/12/2022 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 7336036 |
RIVIERA ELECTRIC, LLC | E= | C | 07/01/2022 | | JOSEPH | JOSEPH | | E= | C | 7433703 |
RIVIERA ELECTRIC, LLC | E= | L | 06/30/2022 | | JOSEPH | JOSEPH | | E= | L | 7431279 |
RIVIERA ELECTRIC, LLC | E= | P | 06/24/2022 | Amend plans to show that nothing goes to panel "A" / Panel "B" is fed with 250 KCMIL & is not fed from a meter stack / Add dedicated circuit for laundry / Dryer circuit should be GFCI protected. / Add plug in Mech room. / Notes Sign circuit fed from house panel. & sign & disconnect both good. | JOSEPH | JOSEPH | | E= | P | 7425372 |
RIVIERA ELECTRIC, LLC | ER | P | 04/07/2022 | Walls only / Discussed accessibility requirements with contractor / Discussed Type V-A construction with contractor. Informed them of prohibition of panels being located in rated walls. / | JOSEPH | JOSEPH | | ER | P | 7329499 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | H= | C | 07/07/2022 | GAS CONTRACTOR FINAL COMPLETE | ANGELW | ANGELW | | H= | C | 7437630 |
THE FURNACE GUY HEATING & COOLING | H= | C | 07/01/2022 | CORE AND SHELL PERMIT COMPLETED / TAB REPORT RECEIVED / | ANGELW | ANGELW | | H= | C | 7433984 |
THE FURNACE GUY HEATING & COOLING | H= | P | 06/30/2022 | TEST AND BALANCE REPORT RECEIVED. SEE IMAGES. FINAL PENDING : THERE IS A CORE AND SHELL PERMIT (# N68320) AND NO MECHANICAL INSPECTIONS HAVE BEEN REQUESTED. FYI - THIS PERMIT CAN NOT FINAL UNTIL THE CORE AND SHELL PERMIT IS FINAL / | LIDO | LIDO | | H= | P | 7431062 |
THE FURNACE GUY HEATING & COOLING | H= | P | 06/23/2022 | AC SEALED LINE SET PENETRATIONS INTO AC BOX (housing) AND LABELED CONDENSERS OK. SEE IMAGES. FINAL PENDING : THERE IS A CORE AND SHELL PERMIT (# N68320) AND NO MECHANICAL INSPECTIONS HAVE BEEN REQUESTED. FYI - THIS PERMIT CAN NOT FINAL UNTIL THE CORE AND SHELL PERMIT IS FINAL / NEED TEST AND BALANCE REPORT / | LIDO | LIDO | | H= | P | 7421711 |
THE FURNACE GUY HEATING & COOLING | H= | P | 06/21/2022 | FINAL PENDING : THERE IS A CORE AND SHELL PERMIT (# N68320) AND NO MECHANICAL INSPECTIONS HAVE BEEN REQUESTED. FYI - THIS PERMIT CAN NOT FINAL UNTIL THE CORE AND SHELL PERMIT IS FINAL / MISSING GROMMET FOR F-1 / F-2 COIL LIQUID AND SUCTION LINE AT COIL BOX / LABEL CONDENSERS IN THE BACK WITH THE ADDRESS SUITE SERVED (130) / NEED TEST AND BALANCE REPORT / | LIDO | LIDO | | H= | P | 7418987 |
THE FURNACE GUY HEATING & COOLING | HD | C | 06/13/2022 | CHANGED TO DUCT ROUGH (HD) INSPECTION (ok for the contractor to request a final for the next inspection) / THERE IS A CORE AND SHELL PERMIT (# N68320) AND NO MECHANICAL INSPECTIONS HAVE BEEN REQUESTED. FYI - THIS PERMIT CAN NOT FINAL UNTIL THE CORE AND SHELL PERMIT IS FINAL / EQUIPMENT SCHEDULE SPLICE FOR ON FILE (carrier furnaces installed ok) / FURNACE F-1 / F-2 8" OUTSIDE AIR INTAKE IS NOW INSTALLED ON THE ROOF AND IS CODE COMPLIANT. NEED REVISED AND APPROVED PLANS SHOWING THIS INSTALL (see note 1). OK TO INSULATE OUTSIDE AIR DUCT / | LIDO | LIDO | | HD | C | 7409719 |
THE FURNACE GUY HEATING & COOLING | HD | C | 06/13/2022 | Continuation of notes / Two 8" outside air ducts that were terminating out the east wall have been capped and abandoned due to not being code compliant. | LIDO | LIDO | | HD | C | 7409816 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | HC | C | 04/05/2022 | RELEASE METER FOR SUITE 130 / | LIDO | LIDO | | HC | C | 7325848 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | HI | C | 04/05/2022 | GAS PIPE INLET LABELED SUITE ADDRESS. SEE IMAGES. | LIDO | LIDO | | HI | C | 7325841 |
THE FURNACE GUY HEATING & COOLING | HV | C | 03/29/2022 | Inspected with Erin B/ CORRECTIONS MADE / FURNACE -1 AND FURNACE -2 - VENT INSTALL COMPLETE /
| LIDO | LIDO | | HV | C | 7318964 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | HI | P | 03/29/2022 | Inspected with Erin B / CORRECT SCOPE OF WORK BY REMOVING THE 2 - GAS LOG INSTALLATION . LABEL GAS PIPE INLET TO BUILDING SUITE 130. METER CAN BE RELEASED AFTER ./ OK TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST / 10 LB TEST OK / GAS PIPE INSTALLED PER PLAN / FINAL GAS CONNECTIONS TO THE TWO FURNACES OK / | LIDO | LIDO | | HI | P | 7318957 |
THE FURNACE GUY HEATING & COOLING | HV | P | 03/22/2022 | FURNACE F-1 AND F-2 : SUPPORT VENT AND INTAKE FROM STRUCTURE WHERE POSSIBLE /
| LIDO | LIDO | | HV | P | 7310194 |
THE FURNACE GUY HEATING & COOLING | HD | P | 03/22/2022 | INSPECTION WITH JON H / NEED GAS CONTRACTOR ATTACHED TO PERMIT / DUCT ROUGH : FURNACE F-2 - HOW IS THE MANUAL VOLUME DAMPER FOR LAUNDRY IS GOING TO BE ACCESSED ABOVE THE HARD LID CEILING? / FURNACE F-1 / FURNACE F-2 - OUTSIDE AIR INTAKES ARE LESS THAN 10 FEET FROM THE EAST SIDE PARKING. SEE 2015 IMC CODE SECTION 401.4 (2). ENGINEER TO ADDRESS ./ MECHANICAL SCHEDULE SHOWS CARRIER FURNACES TO BE INSTALLED RHEEM WAS INSTALLED. NEED REVISED AND APPROVED EQUIPMENT SCHEDULE OR ENGINEER APPROVED SUBMITTAL / F-1 AND F-2 - SUPPLY, RETURN MAIN TRUNK LINES AND BRANCH LINES OK. OK TO INSULATE . / ALL SUPPLY REGISTERS OK / BATHROOM EXHAUST DUCT ROUGH AND TERMINATIONS OK / DRYER EXHAUST DUCT ROUGH AND TERMINATION OK / AC LINE SETS OK / | LIDO | LIDO | | HD | P | 7310193 |
THE FURNACE GUY HEATING & COOLING | HV | P | 03/21/2022 | CALLED CALL AHEAD NUMBER AT 3:33 AND WAS TOLD SOMEONE WOULD BE AT JOB SITE. NOBODY AT JOB SITE AND BUILDING IS LOCKED, NO ACCESS./ | LIDO | LIDO | | HV | P | 7309275 |
THE FURNACE GUY HEATING & COOLING | HD | P | 03/21/2022 | CALLED CALL AHEAD NUMBER AT 3:33 AND WAS TOLD SOMEONE WOULD BE AT JOB SITE. NOBODY AT JOB SITE AND BUILDING IS LOCKED, NO ACCESS./ THERE IS A CORE AND SHELL (permit #N68320) GOING ON AT THE SAME AS THE INTERIOR FINISH PERMIT (no mechanical contractor attached to the core & shell permit? / same builder) / NEED ELECTRICAL CONTRACTOR ATTACHED TO INTERIOR FINISH PERMIT / | LIDO | LIDO | | HD | P | 7309272 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | P= | C | 06/23/2022 | OK for units #130 & #140 (core & shell @ units #100 , #110 & #120) Note : RPBFP for irrigation | FRANKM | FRANKM | | P= | C | 7423483 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | P= | P | 05/31/2022 | No hot water , consultation only / re-inspect all | FRANKM | FRANKM | | P= | P | 7394535 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | PTO | C | 03/29/2022 | OK on in wall & overhead DWV & H2O / insure ADA requirements for plumbing fixtures @ final Note : 3 - VTR / check water entry @ final / check water heater @ final | FRANKM | FRANKM | | PTO | C | 7318738 |
GREATHOUSE AND SPEER PLUMBING AND HEATING | PB | C | 01/26/2022 | Note: OK / 3" Needs Accessible Clean Out By Final | TRAVISR | TRAVISR | | PB | C | 7250526 |
RIVIERA ELECTRIC, LLC | XES | P | 04/12/2022 | PLAN SPLICE: (No Fee) by: BERTHA for Electrical: Revised panel schedule | BERTHA | BERTHA | | XES | P | 7336001 |
THE FURNACE GUY HEATING & COOLING | XMS | P | 04/12/2022 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised equipment schedule | JUSTINC | JUSTINC | | XMS | P | 7335412 |