WELLS & WEST GENERAL CONTRACTORS, INC. | B= | C | 01/10/2023 | | LONNYS | LONNYS | | B= | C | 7630272 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 11/30/2022 | missing international sign of accessibly at both bathrooms / rest OK -- Schedule a new Building Final when above items are complete. | LONNYS | LONNYS | | B= | P | 7596679 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 06/03/2022 | Need to attach mechanical and have rough inspection -- Light gauge frame OK pending other roughs -- Reviewed Accessible Elements | DAKOTAB | DAKOTAB | | BFR | P | 7399430 |
PROCOM ELECTRICAL SERVICES, INC. | E= | C | 08/10/2022 | Drinking Fnt - Ok | BRETC | BRETC | | E= | C | 7477852 |
PROCOM ELECTRICAL SERVICES, INC. | E= | C | 08/10/2022 | FIRE ALARM INSPECTION: | BRETC | BRETC | | E= | C | 7477849 |
PROCOM ELECTRICAL SERVICES, INC. | ER | C | 08/10/2022 | FIRE ALARM INSPECTION: | BRETC | BRETC | | ER | C | 7477847 |
PROCOM ELECTRICAL SERVICES, INC. | ER | R | 07/01/2022 | Need Fire Alarm contractor attached to permit / ------------- Electrical Rough ok, FA not complete ---------------do not sheetrock--------------- / | BRETC | BRETC | | ER | R | 7433647 |
PROCOM ELECTRICAL SERVICES, INC. | ER | P | 06/01/2022 | 1st floor west restroom walls ok. / | LOGANP | LOGANP | | ER | P | 7395555 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 10/11/2022 | TEST AND BALANCE REPORT RECEIVED. SEE IMAGES. | LIDO | LIDO | | H= | C | 7546009 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | P | 06/08/2022 | REGISTERS, GRILLS AND THERMOSTAT OK / FINAL PENDING : NEED TEST AND BALANCE REPORT / | LIDO | LIDO | | H= | P | 7403938 |
DRUMMOND PLUMBING LLC | P= | C | 09/21/2022 | correction made | JOSEPHD | JOSEPHD | | P= | C | 7524918 |
DRUMMOND PLUMBING LLC | P= | P | 07/29/2022 | need trap guards at floor drains, Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / , rest ok | JOSEPHD | JOSEPHD | | P= | P | 7464508 |
DRUMMOND PLUMBING LLC | PTO | C | 07/29/2022 | splice done | JOSEPHD | JOSEPHD | | PTO | C | 7464507 |
DRUMMOND PLUMBING LLC | P= | P | 07/22/2022 | leak in wall, need trap guards at floor drains, need access to drinking fountain shut off, rest ok | JOSEPHD | JOSEPHD | | P= | P | 7456398 |
DRUMMOND PLUMBING LLC | PTO | P | 05/20/2022 | water insulation ok, | JOSEPHD | JOSEPHD | | PTO | P | 7383826 |
DRUMMOND PLUMBING LLC | PTO | P | 05/19/2022 | plans call for 1 1/4 supply to toilets, 1" is run at this time, will need to address on plans, need to see water pipe insulation, rest ok note: need access to shut off for drinking fountain in wall by lavs, | JOSEPHD | JOSEPHD | | PTO | P | 7381974 |
DRUMMOND PLUMBING LLC | XPS | T | 07/06/2022 | PAID (REC#1881012): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 1 revisions: Adjusted sheet P.1. | SHANEN | SHANEN | | XPS | T | 7436044 |