MASTER BILT HOMES, INC. | B= | C | 02/15/2023 | All other required Final inspections are complete. (This is a computer generated result) | JASONL | JASONL | | B= | C | 7662227 |
MASTER BILT HOMES, INC. | B= | P | 10/27/2022 | Final OK pending completion of outstanding inspections. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | JASONL | JASONL | | B= | P | 7564580 |
MASTER BILT HOMES, INC. | BFN | C | 10/27/2022 | Engineer letter for existing foundation on file | JASONL | JASONL | | BFN | C | 7564478 |
MASTER BILT HOMES, INC. | BFT | C | 10/27/2022 | Engineer letter for existing foundation on file | JASONL | JASONL | | BFT | C | 7564477 |
MASTER BILT HOMES, INC. | BFR | P | 10/20/2022 | Observed truss repairs in accordance to repair details on file | JASONL | JASONL | | BFR | P | 7557244 |
MASTER BILT HOMES, INC. | BFR | P | 10/19/2022 | Need to nail off 2nd face of gusset repair in 16 / Need to add construction adhesive to bth sides of repair in 3 / All other corrections complete | JEREMYA | JEREMYA | | BFR | P | 7555353 |
MASTER BILT HOMES, INC. | BSP | P | 10/19/2022 | truss repair details on file, still need to field inspect repairs | JASONL | JASONL | | BSP | P | 7554551 |
MASTER BILT HOMES, INC. | BSP | P | 10/17/2022 | Observed head of wall at interior fire barriers per detail on file | JASONL | JASONL | | BSP | P | 7552798 |
MASTER BILT HOMES, INC. | BFR | P | 10/17/2022 | Missing (2) 2x4 post under AG1 2 ply west side garage 16 / Missing second H2.5T on AG1 2 ply garage 16 east side / Damaged A1 truss garage 16 at gusset and bottom chord / Damaged bottom chord of A2 truss garage 3 / Missing (2) 2x4 under AG1 2 ply garage 1 west side / Missing second H2.5T on AG1 2 ply garage 1 east side | JASONL | JASONL | | BFR | P | 7552796 |
MASTER BILT HOMES, INC. | BSP | R | 06/23/2022 | HEAD OF WALL AT FIRE BARRIERS / Not ready for inspection / Incomplete fire stop and tape at multiple locations / Will need full re inspection / Reviewed items with on site supervisor | JASONL | JASONL | | BSP | R | 7423398 |
MASTER BILT HOMES, INC. | BSP | P | 06/23/2022 | Head of wall detail for fire barriers on file | JASONL | JASONL | | BSP | P | 7421747 |
MASTER BILT HOMES, INC. | BSP | P | 06/21/2022 | EXTERIOR SHEAR / Observed exterior shear and fastening / Still need to inspect bottom plate fastening at exterior walls, OK to check at frame | JASONL | JASONL | | BSP | P | 7419868 |
MASTER BILT HOMES, INC. | BSP | P | 06/02/2022 | GYP AND GYP FASTENING AT FIRE BARRIERS / GA File no. WP 3640 / Observed 5/8 type x gyp and gyp fastening at all fire barriers and interior gyp shear walls / Still need to inspect all fire stop / Reviewed details for fire rated assemblies and design and applied to onsite conditions with on site supervisor (Cory) / pending other rough inspections | JASONL | JASONL | | BSP | P | 7397891 |
MASTER BILT HOMES, INC. | BSP | P | 05/26/2022 | observed wall framing and truss - truss connections above - at 1hr fire barriers / reviewed details for fire rated assemblies and design and applied to onsite conditions with GC / pending other rough inspections | BRIANB | BRIANB | | BSP | P | 7391099 |
MASTER BILT HOMES, INC. | BFN | R | 05/19/2022 | No documents uploaded with inspection request / Spoke with site supervisor (Cory) via phone call to verify use of third party for foundation inspections / No on site inspection requested | JASONL | JASONL | | BFN | R | 7381693 |
MASTER BILT HOMES, INC. | BFT | R | 05/19/2022 | No documents uploaded with inspection request / Spoke with site supervisor (Cory) via phone call to verify use of third party for foundation inspections / No on site inspection requested | JASONL | JASONL | | BFT | R | 7381692 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 10/26/2022 | GDO recepts are gfci protected. | DEAN | DEAN | | E= | C | 7563910 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 10/26/2022 | Need test light in door opener receptacles / | ROB | ROB | | E= | R | 7563675 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 10/14/2022 | Commercial Service: 90 amp 3 wire / Ok to set meter / | ROB | ROB | | ES | C | 7551305 |
FIRST RATE ELECTRICAL SERVICES, INC. | ESP | P | 10/14/2022 | ----------------------------2 ground rods ok, foundation set many years ago without ufer, contractor to change MB to a 90-amp breaker and no splice necessary------------------ | DEAN | DEAN | | ESP | P | 7550338 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | R | 10/13/2022 | Commercial Service: Plan shows #3 CU and #2 AL installed -- rated 90 amps comm. / Need ty handle for MB / Original shows Ufer installed --Will need Ufer to service / | ROB | ROB | | ES | R | 7549952 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 10/13/2022 | Rough ok / | ROB | ROB | | ER | C | 7549947 |
MASTER BILT HOMES, INC. | XES | T | 09/28/2022 | PAID (REC#1902736): PLAN SPLICE FEE: $50 by: RICHG for Electrical: REVISED PLAN | RICHG | RICHG | | XES | T | 7532266 |
MASTER BILT HOMES, INC. | XBS | T | 05/19/2022 | PAID (REC#1868415): PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Trusses | MICHAELA | MICHAELA | | XBS | T | 7381589 |