POULSON CONSTRUCTION, INC. | B= | C | 10/20/2022 | All other required Final inspections are complete. (This is a computer generated result) | TRENTP | TRENTP | | B= | C | 7557065 |
POULSON CONSTRUCTION, INC. | B= | P | 10/17/2022 | Items corrected. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | P | 7552699 |
POULSON CONSTRUCTION, INC. | B= | R | 10/14/2022 | Need to move address numbers on house to be visible from street side approach / Missing code compliant landings outside of both south west sliding glass doors / Need to complete final grade at southwest corner of house / Unfinished basement and attic, no deck, no AC. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 7551170 |
POULSON CONSTRUCTION, INC. | BIN | C | 10/12/2022 | Insulation okay, air leakage on file | TRENTP | TRENTP | | BIN | C | 7548416 |
POULSON CONSTRUCTION, INC. | BFR | C | 10/12/2022 | Items corrected | TRENTP | TRENTP | | BFR | C | 7548415 |
POULSON CONSTRUCTION, INC. | BSP | P | 10/12/2022 | Engineer letter on file for beam splice and collar tie details on file / Pending field inspection | TRENTP | TRENTP | | BSP | P | 7547318 |
POULSON CONSTRUCTION, INC. | BSP | P | 10/10/2022 | Changed to BSP / Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / Note: Still need to complete BFR and observe insulation | TRENTP | TRENTP | | BSP | P | 7544507 |
POULSON CONSTRUCTION, INC. | BSP | R | 09/27/2022 | 1. Incomplete fireblocking throughout garage / 2. Incomplete bottom chord and diagonal web bracing at garage trusses / 3. Need steel beam splice detail basement beam splice 4. Need to secure bottoms of steel posts in basement / 5. Unable to confirmed 26 gauge straps at 2x4 rafters into top chords of trusses below at attic peak frame per detail in plans, multiple rafters do not line up / 6. Multiple pre engineered collar truss webs have been notched to install LVL headers at interior points of dormers / 7. Plans call for 2x8 collar ties, 2x6 collar ties installed / 8. Missing roof jack for dry in at northeast corner / Finished basement, no deck | TRENTP | TRENTP | | BSP | R | 7532027 |
POULSON CONSTRUCTION, INC. | BTD | C | 09/22/2022 | unit # 22-M34677, Factory insignia # 202214478, factory addition insignia # 2022- 14479 , State insignia installed 2022-15978, for frame need to check shear nailing of LUS 210 ay pod joists, by final secure egress ladder, secure monoposts and isolate monoposts | BOBF | BOBF | | BTD | C | 7526336 |
POULSON CONSTRUCTION, INC. | BTD | T | 08/17/2022 | PAID (REC#1892789): Incorrect fasteners used for front pod wall connections / Missing all SST LSTA straps for holddowns at front pod / Joists for front pod in basement still do not bear over steel beam / Multiple joist still do not bear over steel beam, currently in hangers CMST straps not fastened across marriage line in attic / Note: No steel posts in basement at this time / Still need to inspect collar ties at BFR / Update by TP on 8/18/22 After further review, need connection detail for front pod floor joists to main house | TRENTP | TRENTP | | BTD | T | 7486485 |
POULSON CONSTRUCTION, INC. | BTD | R | 08/10/2022 | Tie down incomplete at time of inspection / Gaskets at marriage line damaged or missing thoughout interior / Attic floor straps not installed at time of inspection / Connection of front pod not ready, basement connection does not bear over steel beam, missing hardware / Perimeter fastening at foundation and marriage line fastening at exterior okay / Insignia not set at this time // Note: Collar ties for roof marriage line not done, can inspect at BFR / Multiple floor joists in basement not bearing on steel beams | TRENTP | TRENTP | | BTD | R | 7477539 |
POULSON CONSTRUCTION, INC. | BSP | P | 08/04/2022 | Anchor bolts corrected / Note: Still need to inspect anchor bolts at garage when ready | TRENTP | TRENTP | | BSP | P | 7471310 |
POULSON CONSTRUCTION, INC. | BSP | R | 08/02/2022 | Inspection for anchor bolts at sill plate / Missing anchor bolt within 12 inches of plate breaks throughout eastern and southern sill plates / Note: Garage sill plates not present at time of inspection | TRENTP | TRENTP | | BSP | R | 7468518 |
POULSON CONSTRUCTION, INC. | BFD | C | 07/18/2022 | BFT and BFN complete | TRENTP | TRENTP | | BFD | C | 7449092 |
POULSON CONSTRUCTION, INC. | BFN | C | 07/18/2022 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 7449089 |
POULSON CONSTRUCTION, INC. | BFT | C | 07/18/2022 | open hole on file -- 1000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design in plans (bearing capacity verified) / | TRENTP | TRENTP | | BFT | C | 7449083 |
POULSON CONSTRUCTION, INC. | BFD | R | 07/05/2022 | Need open hole observation / need footing and foundation observations / Drain is usable to sump -- Damp proofing OK / | GREGT | GREGT | | BFD | R | 7434994 |
POULSON CONSTRUCTION, INC. | BFI | P | 06/03/2022 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFI | P | 7398503 |
POULSON CONSTRUCTION, INC. | BFD | P | 06/03/2022 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFD | P | 7398502 |
POULSON CONSTRUCTION, INC. | BFT | P | 06/03/2022 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 7398501 |
POULSON CONSTRUCTION, INC. | BFN | P | 06/03/2022 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 7398500 |
SANCHEZ ELECTRIC, INC. | E= | C | 10/13/2022 | | TOMC | TOMC | | E= | C | 7549002 |
SANCHEZ ELECTRIC, INC. | ES | C | 10/13/2022 | Residential Underground: 200-amp 3-wire service upgrade, no action required by utility. / | TOMC | TOMC | | ES | C | 7548999 |
SANCHEZ ELECTRIC, INC. | E= | R | 09/28/2022 | install cover plate garage , receptacle plate at sump and ejector , bend ufer into wall tripping hazard , wiring not in conduit across driveway ?Need to install "Emergency Disconnect/Service Disconnect" label on the exterior of the service enclosure. / | BRET | BRET | | E= | R | 7532509 |
SANCHEZ ELECTRIC, INC. | ER | C | 09/28/2022 | | BRET | BRET | | ER | C | 7532508 |
SANCHEZ ELECTRIC, INC. | EP | C | 09/28/2022 | 2-200 amp sub panels | BRET | BRET | | EP | C | 7532507 |
SANCHEZ ELECTRIC, INC. | EUG | C | 08/29/2022 | 4/0-4/0-2/0 #4 ok to backfill | BRET | BRET | | EUG | C | 7499190 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 10/06/2022 | Whole house ventilation being achieved through exhaust fan located in future basement bathroom. / Whole house ventilation switch located at bottom of stair well / NOTE / Unfinished basement / No outside air to furnace return / Direct vent furnace / Direct vent tankless water heater / No A/C / Regulators set at furnace and tankless water heater / | CASEYM | CASEYM | | H= | C | 7541891 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 10/06/2022 | RELEASE 2LB METER | CASEYM | CASEYM | | HC | C | 7541890 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 10/06/2022 | Whole house ventilation being achieved through exhaust fan located in future basement bathroom. / Whole house ventilation switch located at bottom of stair well / NOTE / Unfinished basement / No outside air to furnace return / Direct vent furnace / Direct vent tankless water heater / No A/C / Regulators set at furnace and tankless water heater / | CASEYM | CASEYM | | HRR | C | 7541878 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 10/05/2022 | Heat final pending corrections stated in HRR comments / Whole house ventilation being achieved through exhaust fan located in future basement bathroom. / Whole house ventilation switch located at bottom of stair well / NOTE / Unfinished basement / No outside air to furnace return / Direct vent furnace / Direct vent tankless water heater / No A/C / Regulators set at furnace and tankless water heater / | CASEYM | CASEYM | | H= | P | 7540228 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 10/05/2022 | Repair damaged trunk line over I-beam on south end of basement / Seal unused knockout on bottom front of furnace cabinet / Cap/seal kitchen exhaust duct / Per builder, chase to be built around dryer exhaust duct in garage, not installed at time of inspection / Whole house ventilation being achieved through exhaust fan located in future basement bathroom. / Whole house ventilation switch located at bottom of stair well / NOTE / Unfinished basement / No outside air to furnace return / Direct vent furnace / Direct vent tankless water heater / No A/C / Regulators set at furnace and tankless water heater / | CASEYM | CASEYM | | HRR | P | 7540224 |
SPRINGS GAS, INC. | HSP | P | 09/21/2022 | **Changed to HC to HSP 9-21-2022 CM**
HRR inspection must be completed before releasing the meter / | CASEYM | CASEYM | | HSP | P | 7524061 |
SPRINGS GAS, INC. | HO | C | 08/25/2022 | Need 2lb approval letter from gas provider at final / Whole house and undergound gas system on same test, 10lb test ok / 150' of 3/4" PE with tracer wire from meter at street to house / Ok to cover / | CASEYM | CASEYM | | HO | C | 7495512 |
SPRINGS GAS, INC. | HI | C | 08/25/2022 | Need 2lb approval letter from gas provider by final / Verify regulators at final (one at furnace and one at tankless water heater) / 10 lb test ok / 3/4 inch main / 1 furnace / 1 tankless water heater / | CASEYM | CASEYM | | HI | C | 7495506 |
ABOVE WATER PLUMBING & HEATING, LLC | P= | C | 10/04/2022 | | TAYLOR | TAYLOR | | P= | C | 7538294 |
ABOVE WATER PLUMBING & HEATING, LLC | PTO | C | 10/04/2022 | see images. | TAYLOR | TAYLOR | | PTO | C | 7538290 |
ABOVE WATER PLUMBING & HEATING, LLC | P= | P | 09/30/2022 | complete PTO inspection, rest ok, note: unfinished basement, no irrigation. | TAYLOR | TAYLOR | | P= | P | 7535961 |
ABOVE WATER PLUMBING & HEATING, LLC | PTO | P | 09/30/2022 | need proper vent termination from operable window, rest ok. | TAYLOR | TAYLOR | | PTO | P | 7535957 |
ABOVE WATER PLUMBING & HEATING, LLC | PTO | C | 09/29/2022 | ENTRY FOR POTABLE H20 CERT | LEE | LEE | | PTO | C | 7533788 |
ABOVE WATER PLUMBING & HEATING, LLC | PSP | P | 09/28/2022 | Water Heater Plastic Vent by Other | SYSTEM | SYSTEM | | PSP | P | 7533660 |
POULSON CONSTRUCTION, INC. | PWO | C | 09/26/2022 | | LEE | LEE | | PWO | C | 7529800 |
ABOVE WATER PLUMBING & HEATING, LLC | PB | C | 07/14/2022 | FOR FULL BATH AND EJECTOR PIT | LEE | LEE | | PB | C | 7446252 |