AVA'S CONSTRUCTION LLC | B= | C | 01/04/2024 | building final OK | LONNYS | LONNYS | | B= | C | 7959498 |
AVA'S CONSTRUCTION LLC | BFR | P | 12/20/2023 | units 1021 and 1030 interior light gauge steel wall framing and gyp attachment OK | LONNYS | LONNYS | | BFR | P | 7949892 |
AVA'S CONSTRUCTION LLC | BFR | P | 12/14/2023 | unit 1040 light gauge steel kitchen wall framing OK | LONNYS | LONNYS | | BFR | P | 7945041 |
AVA'S CONSTRUCTION LLC | BSP | P | 12/05/2023 | 1105 and 1119 gyp attachment OK | LONNYS | LONNYS | | BSP | P | 7935137 |
AVA'S CONSTRUCTION LLC | BFR | P | 12/04/2023 | units 1105 and 1119 kitchen wall framing OK | LONNYS | LONNYS | | BFR | P | 7934140 |
AVA'S CONSTRUCTION LLC | BFR | P | 11/28/2023 | unit 1054 kitchen wall gyp attachment OK | LONNYS | LONNYS | | BFR | P | 7928547 |
AVA'S CONSTRUCTION LLC | BFR | P | 11/27/2023 | Unit 1054 - Frame okay pending other rough inspections. | ERAMIREZ | ERAMIREZ | | BFR | P | 7927431 |
AVA'S CONSTRUCTION LLC | BSP | P | 11/07/2023 | 2nd side gyp attachment at all pass through door in fills OK / building final OK // UPDATE: 11-7-2023 by Lonny S -- Upon Further Review, / inspection type changed from B= to BSP / status changed from complete to partial / still need building final inspection and address interior unit framing for kitchen area walls being not FRT | LONNYS | LONNYS | | BSP | P | 7910577 |
AVA'S CONSTRUCTION LLC | BFR | P | 11/06/2023 | unit pass through door in fill framing and one side gyp attachment OK all units per UL U305 | LONNYS | LONNYS | | BFR | P | 7909471 |
AVA'S CONSTRUCTION LLC | BFR | P | 08/30/2023 | unit 1044 -- 3 doors infill framing OK - corridor side and corridor door infill OK per UL U419
interior side gyp attachment at exterior door in fills OK per UL U305 | LONNYS | LONNYS | | BFR | P | 7842036 |
AVA'S CONSTRUCTION LLC | BFR | R | 06/05/2023 | still need to update plan for as built conditions / observed 2x4 combustible framing at new wing walls in loft units - this is not permitted in I-A construction / no other inspections performed for pass through infills | LONNYS | LONNYS | | BFR | R | 7762318 |
AVA'S CONSTRUCTION LLC | BSP | P | 05/24/2023 | site visit to review project status and as built conditions / need to update plans for as built condition / reviewed rated assemblies,required PPRBD inspections, V-A construction, and rated assembly continuity requirements | LONNYS | LONNYS | | BSP | P | 7753243 |
AVA'S CONSTRUCTION LLC | BE | L | 03/30/2023 | Renewed online for Half Fee at Mar 30 2023 8:33AM (RECEIPT #: 1943233) | WEBSITE | WEBSITE | | BE | L | 7702429 |
EL PASO ELECTRIC, LLC. | E= | C | 11/01/2023 | 1044 ok | JIMMY | JIMMY | | E= | C | 7905864 |
EL PASO ELECTRIC, LLC. | ER | C | 08/21/2023 | 1044---ok / | BRIAN | BRIAN | | ER | C | 7831999 |
EL PASO ELECTRIC, LLC. | ER | R | 08/16/2023 | 1044 not ready / need deeper mudrings / | BRIAN | BRIAN | | ER | R | 7827949 |
EL PASO ELECTRIC, LLC. | ER | R | 08/07/2023 | unit 1044 need back out framing complete / add recepts for new doorways / | BRIAN | BRIAN | | ER | R | 7818835 |
EL PASO ELECTRIC, LLC. | E= | P | 07/18/2023 | all units except 1044 / still need er and final on this unit / | BRIAN | BRIAN | | E= | P | 7801111 |
EL PASO ELECTRIC, LLC. | E= | P | 06/08/2023 | center tower --see plans --owner work units / | BRIAN | BRIAN | | E= | P | 7766625 |
EL PASO ELECTRIC, LLC. | E= | P | 06/06/2023 | marked in green on plans / center tower 1st floor units / | BRIAN | BRIAN | | E= | P | 7763713 |
EL PASO ELECTRIC, LLC. | E= | P | 05/24/2023 | owner work--ok / units 2100 through 2115---see plans | BRIAN | BRIAN | | E= | P | 7753217 |
EL PASO ELECTRIC, LLC. | E= | P | 05/15/2023 | the loft units --5 units--ok / see plans / | BRIAN | BRIAN | | E= | P | 7744210 |
EL PASO ELECTRIC, LLC. | E= | P | 04/20/2023 | units in center 1st floor ---see plans | BRIAN | BRIAN | | E= | P | 7722540 |
EL PASO ELECTRIC, LLC. | ER | P | 03/28/2023 | loft units --see plans --6 units / | BRIAN | BRIAN | | ER | P | 7700015 |
EL PASO ELECTRIC, LLC. | ER | P | 03/20/2023 | units on 1st floor west wing---ok see plans /. | BRIAN | BRIAN | | ER | P | 7691932 |
EL PASO ELECTRIC, LLC. | ER | P | 03/17/2023 | 1st floor rooms marked on plans / | MIGUEL | MIGUEL | | ER | P | 7690347 |
EL PASO ELECTRIC, LLC. | ER | P | 03/16/2023 | 2nd floor units ---see plans / | BRIAN | BRIAN | | ER | P | 7689126 |
EL PASO ELECTRIC, LLC. | ER | P | 02/23/2023 | 1st and 2nd floor units in center--ok see plans / | BRIAN | BRIAN | | ER | P | 7668477 |
EL PASO ELECTRIC, LLC. | ER | P | 02/22/2023 | walls marked on plans, except lofts- 1105, 1119 / | MIGUEL | MIGUEL | | ER | P | 7667210 |
EL PASO ELECTRIC, LLC. | ER | R | 02/21/2023 | no one on site / | MIGUEL | MIGUEL | | ER | R | 7666611 |
AVA'S CONSTRUCTION LLC | XBS | T | 08/17/2023 | PAID (REC#1979824): PLAN SPLICE FEE: $50 by: DANM for Construction: Remove accessible label designation on several existing units based on actual field conditions | DANM | DANM | | XBS | T | 7829573 |
AVA'S CONSTRUCTION LLC | XBS | T | 08/02/2023 | PAID (REC#1975356): PLAN SPLICE FEE: $50 by: DANM for Construction: Change infill wall construction between units from CMU construction to fire-retardant-treated wood with new listed assembly | DANM | DANM | | XBS | T | 7814861 |
AVA'S CONSTRUCTION LLC | XBS | T | 07/18/2023 | PAID (REC#1970718): PLAN SPLICE FEE: $50 by: DANM for Construction: Remove existing doors from between units and remove wall existing wall extensions with kitchenettes | DANM | DANM | | XBS | T | 7800422 |