CUVALA CONSTRUCTION, INC. | B= | C | 05/08/2023 | All other required Final inspections are complete. (This is a computer generated result) | GREGT | GREGT | | B= | C | 7738170 |
CUVALA CONSTRUCTION, INC. | B= | P | 05/08/2023 | Unfinished basement / no deck / A/C installed. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | GREGT | GREGT | | B= | P | 7737994 |
CUVALA CONSTRUCTION, INC. | BSP | P | 05/05/2023 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BSP | P | 7736363 |
CUVALA CONSTRUCTION, INC. | BIN | C | 05/03/2023 | Installers certificate for blown in insulation on file / Need to provide air leakage test results by approved 3rd party by final | JASONL | JASONL | | BIN | C | 7733787 |
CUVALA CONSTRUCTION, INC. | BIN | P | 01/30/2023 | Need to provide installers certificate for blown in insulation, observed 5 1/2 inches in walls / Need air leakage test results by final | TRENTP | TRENTP | | BIN | P | 7648050 |
CUVALA CONSTRUCTION, INC. | BSP | P | 01/30/2023 | Final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | BSP | P | 7647610 |
CUVALA CONSTRUCTION, INC. | BSP | P | 01/26/2023 | Need to provide installers certificate for product used for fire protection of floors / Test report for materials used in fire protection of floor per IRC 302.13 EX #4 on file / | TRENTP | TRENTP | | BSP | P | 7644944 |
CUVALA CONSTRUCTION, INC. | BFR | C | 01/26/2023 | Engineer letter on file for rafter to girder attachment | TRENTP | TRENTP | | BFR | C | 7644933 |
CUVALA CONSTRUCTION, INC. | BFR | P | 01/25/2023 | Still need to complete #1 from previous inspection / Rest okay | TRENTP | TRENTP | | BFR | P | 7644215 |
CUVALA CONSTRUCTION, INC. | BFR | P | 01/25/2023 | Still need to complete #1 from previous inspection / Rest okay | TRENTP | TRENTP | | BFR | P | 7644216 |
CUVALA CONSTRUCTION, INC. | BFR | P | 01/24/2023 | 1. Need clarification for missing ledger at roof for rafter attachment / 2. Incomplete fireblocking between stud that transfer through floor at eastern exterior wall and next to stairs at south exterior wall / 3. Need to provide repair of cut out floor joist next to basement stairs / 4. Need to provide mono post at beam pocket for small drop beam next to stairs / 5. Need to provide decay resistive framing for post holding small drop beam next to stairs // Provide Test report and installers certificate for materials used for fire protection of floor per IRC 302.13 EX #4 / Unfinished basement, no deck | TRENTP | TRENTP | | BFR | P | 7642988 |
CUVALA CONSTRUCTION, INC. | BSP | P | 01/13/2023 | Engineered truss repair on file | TRENTP | TRENTP | | BSP | P | 7633997 |
CUVALA CONSTRUCTION, INC. | BSP | R | 12/30/2022 | Truss inspection--Provide engineer letter for eybrow truss repair./ Missing ledger at upper joist to truss connection./ Rest of trusses and truss connections OK | RYANF | RYANF | | BSP | R | 7623105 |
CUVALA CONSTRUCTION, INC. | BFI | C | 09/26/2022 | | TRENTP | TRENTP | | BFI | C | 7529189 |
CUVALA CONSTRUCTION, INC. | BFD | C | 09/26/2022 | | TRENTP | TRENTP | | BFD | C | 7529188 |
CUVALA CONSTRUCTION, INC. | BFN | C | 09/21/2022 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 7524186 |
CUVALA CONSTRUCTION, INC. | BFT | C | 09/21/2022 | open hole on file -- 2000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | TRENTP | TRENTP | | BFT | C | 7524181 |
CUVALA CONSTRUCTION, INC. | BFD | P | 09/21/2022 | Soils and open hole on file, 2000 psf - usable - 10% / Need to complete BFT and BFN | TRENTP | TRENTP | | BFD | P | 7523953 |
CUVALA CONSTRUCTION, INC. | BFD | P | 09/20/2022 | Need to upload soils report/open hole with drain design observed on site / Observed typical drain around usable to daylight at east side, dampproofing okay / Drain ok / Contractor to backfill per requirements of Soils Report / | TRENTP | TRENTP | | BFD | P | 7523589 |
CUVALA CONSTRUCTION, INC. | BFI | P | 09/20/2022 | R10 installed / Need to complete BFT and BFN | TRENTP | TRENTP | | BFI | P | 7523578 |
CUVALA CONSTRUCTION, INC. | BFN | P | 09/16/2022 | Need to complete BFT / Need to provide soils report/open hole / Need to provide foundation design / Engineer letter for footing and foundation on file -- Eufer noted / | TRENTP | TRENTP | | BFN | P | 7519226 |
PORCH ELECTRIC, INC. | E= | C | 04/11/2023 | E= OK ------ 30 AMP A/C ----- | GREGM | GREGM | | E= | C | 7712537 |
PORCH ELECTRIC, INC. | ES | C | 04/11/2023 | Residential Underground: 200-amp 3 Wire New Residence ok need meter seal. / | GREGM | GREGM | | ES | C | 7712536 |
PORCH ELECTRIC, INC. | EUG | C | 02/02/2023 | EUG ---- 1/0 #6 ---- | GREGM | GREGM | | EUG | C | 7651179 |
PORCH ELECTRIC, INC. | EP | C | 02/02/2023 | EP OK ------ 125 AMP ---- IRR UFER ----- | GREGM | GREGM | | EP | C | 7651173 |
PORCH ELECTRIC, INC. | ER | C | 01/10/2023 | ER OK ---- GAS RANGE ---- # 10 A/C ---- UNFINISHED BASEMENT ----- UFER NOT IN AT THIS TIME ------ | GREGM | GREGM | | ER | C | 7630338 |
MINNICK ENTERPRISES INC. | H= | C | 04/14/2023 | WHOLE HOUSE VENTILATION SWITCH LOCATED IN LAUNDRY ROOM / WHOLE HOUSE VENTILATION BEING ACHIEVED WITH EXHAUST FAN LOCATED IN LAUNDRY ROOM / NOTE / UNFINISHED BASEMENT / NO OUTSIDE AIR TO FURNACE RETURN / DIRECT VENT FURNACE / HIGH/LOW GRILLES INTO WATER HEATER CLOSET / A/C COMPLETE / | MATTM | MATTM | | H= | C | 7716575 |
O.M.A.G.M., INC. | HO | C | 02/06/2023 | Need 2lb approval letter from gas provider by final / Verify regulators and medium pressure stenciling at final /
10lb test ok on 450' of 1 1/4" PE with tracer wire from meter to house and detached garage / Ok to cover / | CASEYM | CASEYM | | HO | C | 7653889 |
O.M.A.G.M., INC. | HC | C | 02/02/2023 | RELEASE 2LB METER / | CASEYM | CASEYM | | HC | C | 7651369 |
O.M.A.G.M., INC. | HSP | P | 02/02/2023 | Per gas contractor, this address will now be on a 2lb system with the addition of gas line in detached garage for future heater under permit #O49468 (see HI comments under that permit / Need 2lb approval letter by final and HO inspection when underground gas line is installed / Per contractor, regulator will be set at riser to house and riser to garage, verify regulators and medium pressure stenciling at final / | CASEYM | CASEYM | | HSP | P | 7651364 |
O.M.A.G.M., INC. | HC | C | 01/23/2023 | RELEASE METER | CASEYM | CASEYM | | HC | C | 7641948 |
O.M.A.G.M., INC. | HI | C | 01/23/2023 | 10 lb test ok / 1 1/4 inch main / 1 furnace / 1 water heater / 1 range / 1 fireplace / 1 Dryer / One 1/2" stub at front patio good for up to 65K BTUs at 55' / | CASEYM | CASEYM | | HI | C | 7641944 |
MINNICK ENTERPRISES INC. | HRR | C | 01/17/2023 | Insulation shield installed on b-vent, see images / | CASEYM | CASEYM | | HRR | C | 7635613 |
MINNICK ENTERPRISES INC. | HRR | P | 01/12/2023 | Questioning if insulation is being installed in attic space above upper level, insulation shield not installed on water heater b-vent / Whole house ventilation being achieved with exhaust fan located in laundry room. / Verify whole house ventilation switch location at final / NOTE / Unfinished basement / No outside air to furnace return / Direct vent furnace / A/C rough, coil and lineset. / Duct for basement bathroom installed at exterior wall and capped for future use / | CASEYM | CASEYM | | HRR | P | 7633403 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 12/27/2022 | Main level fireplace clearance to combustibles and vent termination ok. / Non-combustible materials installed / | CASEYM | CASEYM | | HV | C | 7620359 |
HOGAN MECHANICAL, INC. | P= | C | 04/24/2023 | Certificate of potable water in images / Corrections in images | ADRIANM | ADRIANM | | P= | C | 7724461 |
HOGAN MECHANICAL, INC. | P= | P | 04/14/2023 | Water heater floor drain needs caulked / Water heater floor drain needs trap guard / Where is aav for hall lav? / Need certificate of potable water (no history) / Rest OK | ADRIANM | ADRIANM | | P= | P | 7717537 |
HOGAN MECHANICAL, INC. | PTO | C | 01/06/2023 | ONE VTR -- AAV @ MASTER LAV, UPPER HALL LAV -- UF-BSMT -- ELECT. W/H | LEE | LEE | | PTO | C | 7627538 |
HOGAN MECHANICAL, INC. | PWO | C | 10/11/2022 | SANITARY HYDRANT INSTALLED JUST OUTSIDE POLE BARN -- WATER SERVICE ABANDONED INSIDE THIS STRUCTURE | LEE | LEE | | PWO | C | 7546422 |
HOGAN MECHANICAL, INC. | PB | C | 09/27/2022 | 3" STACK C/O REQUIRES ACCESS THRU FINAL | LEE | LEE | | PB | C | 7531042 |
HOGAN MECHANICAL, INC. | PWO | P | 09/26/2022 | WATER TO NEW RESIDENCE OK -- WHO INSPECTED WATER TO POLE BARN / OUT BUILDING ( NO HISTORY ) ?? | LEE | LEE | | PWO | P | 7529396 |