HOMEOWNER | B= | P | 02/05/2024 | Need H=+ inspection for mechanical final on additional bedroom per note on splice / Rest of building final ok -- Schedule a new Building Final when above items are complete. UPDATE: 03/07/24 by JeremyD -- Upon Further Review, separate permit required for additional basement bedroom - Final ok once new permit is established | JEREMYD | JEREMYD | | B= | P | 7986551 |
HOMEOWNER | B= | R | 02/02/2024 | Still need to update plans for as built conditions per last B= inspection./ Other items corrected | RYANF | RYANF | | B= | R | 7985241 |
HOMEOWNER | B= | R | 01/10/2024 | Need to contact plan review to update plans for as-built conditions in basement - Observed additional non-bearing wall and closet framed and finished to form 3rd bedroom in SE corner / Missing code-compliant address numbers / Greater than 30" fall within 36" of walkway at (2) window wells on West and South elevation / Bottom rung of (3) basement bedroom egress window well ladders to be no more than 18" from ground / Rest ok / Finished basement - AC installed - No deck | JEREMYD | JEREMYD | | B= | R | 7964253 |
HOMEOWNER | BIN | C | 01/08/2024 | | JEREMYD | JEREMYD | | BIN | C | 7961791 |
HOMEOWNER | BFR | C | 01/08/2024 | Letter for alternate rear sliding door on file | JEREMYD | JEREMYD | | BFR | C | 7961790 |
HOMEOWNER | BSP | P | 12/20/2023 | Air Leakage Testing Report (Blower Door) per 2015 IECC section R402.4.1 on file | JEREMYD | JEREMYD | | BSP | P | 7949812 |
HOMEOWNER | BIN | R | 06/19/2023 | BIN ok upon completion of frame inspection / Reviewed Air Leakage Testing Report per 2015 IECC section R402.4.1.2 to be provided by final inspection | JEREMYD | JEREMYD | | BIN | R | 7775519 |
HOMEOWNER | BFR | P | 06/12/2023 | Rear sliding door still not built to 4/s4 detail - Letter in process / Rest ok | JEREMYD | JEREMYD | | BFR | P | 7768862 |
HOMEOWNER | BFR | R | 06/07/2023 | Missing garage overhead doors for dry-in / Rear sliding door not built to 4/s4 detail - update plans for as-built conditions / Missing 2nd H2.5 on (4) trusses over rear sliding door / Missing 2nd H2.5 on A1 truss over East-facing windows in den / Missing LUS and LS hangers under stair landing / Missing 3" dia steel post at corner of stair LVLs in basement / Isolate steel posts in basement / Rest ok - Finished basement | JEREMYD | JEREMYD | | BFR | R | 7765105 |
HOMEOWNER | BSP | P | 06/01/2023 | Fireblocking at concealed spaces ok | JEREMYD | JEREMYD | | BSP | P | 7759876 |
HOMEOWNER | BFD | C | 06/01/2023 | Drain is installed usable to exterior sump pit / Contractor to backfill per requirements of Soils Report | JEREMYD | JEREMYD | | BFD | C | 7759873 |
HOMEOWNER | BLA | C | 03/08/2023 | | JEREMYD | JEREMYD | | BLA | C | 7681448 |
HOMEOWNER | BSP | P | 03/08/2023 | Complete BFD / Front porch posts and lid frame ok | JEREMYD | JEREMYD | | BSP | P | 7681437 |
HOMEOWNER | BSP | P | 02/14/2023 | Complete BFD / Garage portals ok / West elevation window portal ok | JEREMYD | JEREMYD | | BSP | P | 7661421 |
HOMEOWNER | BFD | R | 02/14/2023 | Cannot spot-approve drain - Inspector must see entire drain installation / Still cannot identify method of drainage - sump pit or daylight / Please provide stamped licensed designer observation for drain backfilled prior to inspection / Damp-proofing ok | JEREMYD | JEREMYD | | BFD | R | 7661420 |
HOMEOWNER | BSP | R | 02/10/2023 | Complete BFD / Garage portal requested / Missing anchor bolts and 2" x 2" x 3/16" plate washers at interior garage portals / Missing horizontal blocking and nailing at panel edges / Missing LSTI49 and MSTC52 straps at interior garage portals - Observed CS16 straps installed | JEREMYD | JEREMYD | | BSP | R | 7659063 |
HOMEOWNER | BFD | R | 12/28/2022 | Please provide stamped licensed designer observation with damp-proofing note for drain backfilled prior to inspection / Drain is not currently connected to street, sump pit, or daylighted | JEREMYD | JEREMYD | | BFD | R | 7621335 |
HOMEOWNER | BFN | C | 12/22/2022 | | JEREMYD | JEREMYD | | BFN | C | 7618843 |
HOMEOWNER | BFT | C | 12/22/2022 | Foundation Design on file (bearing capacity verified) | JEREMYD | JEREMYD | | BFT | C | 7618840 |
HOMEOWNER | BSP | P | 12/21/2022 | Still need to provide stamped Foundation Design with soil bearing capacity or stamped letter defining bearing capacity of foundation design / open hole on file -- 1500 psf | JEREMYD | JEREMYD | | BSP | P | 7617285 |
HOMEOWNER | BFT | R | 11/16/2022 | Still need to provide stamped Open Hole and Foundation Design with soil bearing capacity or stamped letter defining bearing capacity of foundation design / Footing and Foundation Observation on file - ufer noted | JEREMYD | JEREMYD | | BFT | R | 7584685 |
HOMEOWNER | BFN | L | 11/08/2022 | Post address / Property gate locked - Call ahead verified at 11:05 am - No answer at call ahead number / Foundation already appears to be poured - Please provide footing and foundation observation with ufer note and stamped Open Hole / Soil bearing capacity omitted from Foundation Design on file / Soils Report in plan images -- 5% -- usable | JEREMYD | JEREMYD | | BFN | L | 7576256 |
HOMEOWNER | E= | C | 09/12/2023 | Photo of bath receptacle relocation and kitchen island counter receptacle ok - complete | CHIPO | CHIPO | | E= | C | 7853058 |
HOMEOWNER | E= | R | 09/08/2023 | Can not have receptacle within 3 feet of edge of tub or shower. Receptacle for left master bath vanity needs to be relocated to area between sinks / need one counter top receptacle for kitchen island. Can be pop up on top, side mounted in cabinet, or near top corner of sheet rock just under counter to overhang - all else ok - 30 amp water heater, 30 amp well, 20 amp A/C ok - Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | CHIPO | CHIPO | | E= | R | 7851342 |
HOMEOWNER | ES | C | 08/30/2023 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | CRAIG | CRAIG | | ES | C | 7841861 |
HOMEOWNER | ES | R | 08/29/2023 | Residential Underground: owner need to dig up trench by side walk to verify pvc is past concrete --------------- install insulators to main lugs in main disconnect ---------------- 200 amp 3/w Picture upload requested: If on site inspection is scheduled, a trip fee will be assessed. / | CRAIG | CRAIG | | ES | R | 7840753 |
HOMEOWNER | ER | C | 06/05/2023 | Correction made with ground and well circuit - rough in ok | CHIPO | CHIPO | | ER | C | 7762884 |
HOMEOWNER | ER | R | 04/17/2023 | INSTALL WELL CIRCUIT ------------ INSTALL EQUIPMENT GROUND WIRE FROM MAIN DISCONNECT TO SUB PANEL -------------- REST OK 2020 CODE NO MCC 10/2 10/3 6/3 AL 4/W #2 AL TO BASEMENT SUB PANEL 20 AMP TO HOOD AND ELECTRIC FIRE PLACE FRIDGE / IGNITER ON SMALL No Cent Vac / Irreversible UFER connection / Finished Basement / | CRAIG | CRAIG | | ER | R | 7718685 |
HOMEOWNER | EUG | C | 03/10/2023 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 7684319 |
HOMEOWNER | HSP | P | 03/07/2024 | SPOKE WITH HOMEOWNER ABOUT 3RD BASEMENT BEDROOM. NO NOTES ON BUILD PERMIT INDICATE THAT THERE HAS ALWAYS BEEN 3 BEDROOMS IN BASEMENT, AND THE ORIGINAL PLANS SHOW ONLY 2 BASEMENT BEDROOMS, AND NEW SPLICE FOR 3RD BEDROOM WAS SUBMITTED AND APPROVED AFTER MECHANICAL AND ELECTRICAL HAD BEEN COMPLETED. AFTER SPEAKING TO SENIOR BUILDING INSPECTOR, AND CHIEF MECHANICAL INSPECTOR, FOR THIS BASEMENT BEDROOM, A NEW REMODEL PERMIT WILL BE REQUIRED TO INCLUDE BUILDING, MECHANICAL, AND ELECTRICAL. | JHORSMAN | JHORSMAN | | HSP | P | 8017097 |
HOMEOWNER | H= | C | 01/08/2024 | CORRECTIONS MADE SEE IMAGES | NICKE | NICKE | | H= | C | 7961748 |
HOMEOWNER | H= | P | 01/05/2024 | PROVIDE PICTURE OF FURNACE VENT TERMINATION. REST OF CORRECTIONS OK | NICKE | NICKE | | H= | P | 7960472 |
HOMEOWNER | H= | P | 12/20/2023 | PROPERLY TERMINATE FURNACE VENTING/ INSTALL A/C CONDENSATE DRAIN/ LINESET INSULATION TO TERMINATE AT COIL CABINET. OK TO ATTACH PICTURES OF CORRECTIONS AT NEXT INSPECTION REQUEST/ Whole house ventilation being achieved with exhaust fan located in laundry room. / Whole house ventilation switch located in laundry room / NOTE / FINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / ELECTRIC WATER HEATER / A/C COMPLETE / | JHORSMAN | JHORSMAN | | H= | P | 7950455 |
HOMEOWNER | HI | C | 06/05/2023 | 10 LB TEST OK / 1 INCH MAIN / 1 FURNACE / | NICKE | NICKE | | HI | C | 7762463 |
HOMEOWNER | HI | P | 06/01/2023 | LINE NOT UNDER TEST EXPLAINED TO HOMEOWNER THE 10LB TEST PROCESS | NICKE | NICKE | | HI | P | 7760196 |
HOMEOWNER | HRP | C | 04/27/2023 | 400 LB LINESET TEST OK | JHORSMAN | JHORSMAN | | HRP | C | 7729180 |
HOMEOWNER | HRR | C | 04/27/2023 | FIREPLACE IS ELECTRIC ELECTRICAL INSPECTOR TO VERIFY FIREPLACE/ | JHORSMAN | JHORSMAN | | HRR | C | 7729174 |
HOMEOWNER | HO | C | 04/17/2023 | 10 LB TEST OK ON 69 FEET OF 3/4 INCH PE WITH TRACER WIRE FROM PROPANE TANK LOCATION TO RISER AT SIDE OF HOUSE/ OK TO COVER | JHORSMAN | JHORSMAN | | HO | C | 7718254 |
HOMEOWNER | HRR | P | 04/17/2023 | HOUSE IS FRAMED FOR A FIREPLACE, FIREPLACE IS ON MECHANICAL AND ARCHITECTURAL PLANS/. HRR CANNOT BE COMPLETE UNTIL FIREPLACE IS INSTALLED AND HV INSPECTION IS CALLED/ BY FINAL LABEL DAMPER/ MISSING RETURN IN DEN/ INSTALL NAIL PROTECTION ON BACK SIDE OF DRYER EXHAUST DUCT/ LINESET REQUIRES HRP INSPECTION DUE TO JOINTS IN LINESET WITHIN CEILING OF ROOM ADJACENT TO MECHANICAL ROOM/ FULLY INSULATE LINESET ABOVE ROOM ADJACENT TO MECHANICAL ROOM/ REC ROOM MISSING RETURN/ Whole house ventilation being achieved with exhaust fan located in laundry room. / Verify whole house ventilation switch location at final / NOTE / FINISHED BASEMENT / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / DIRECT VENT FURNACE / ELECTRIC WATER HEATER / A/C ROUGH, COIL AND LINESET / | JHORSMAN | JHORSMAN | | HRR | P | 7718235 |
HOMEOWNER | HO | P | 03/31/2023 | CALL AHEAD PLACED AT 1:30 P.M./ NO ACCESS TO PROPERTY DUE TO LOCKED GATE AT ENTRANCE/ | JHORSMAN | JHORSMAN | | HO | P | 7704489 |
HOMEOWNER | P= | C | 01/05/2024 | potable water certification in images, laundry sink ok, see images | JOSEPHD | JOSEPHD | | P= | C | 7960461 |
HOMEOWNER | P= | P | 01/02/2024 | still need to see laundry sink sealed at wall and still need potable water certification, other corrections made | JOSEPHD | JOSEPHD | | P= | P | 7956914 |
HOMEOWNER | PSP | C | 01/02/2024 | hammer arrestors and aav at lav ok see images, | JOSEPHD | JOSEPHD | | PSP | C | 7956910 |
HOMEOWNER | P= | P | 12/20/2023 | STILL NEED POTABLE WATER CERTIFICATE
just need to seal sink in laundry to back wall, need hammer arrestors at washer box for hot and cold supply lines, caulk bsmnt tub spout, need aav's at bsmnt lavs, can complete with DETAILED UPLOADED IMAGES OF CORRECTIONS AND POTABLE WATER CERT
please upload the photos (3 only) on a P= inspection, the other photos can be upload to a PSP inspection
Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o /
rest ok. NOTE: finished bsmnt, no irrigation, elec water htr | JOHNS | JOHNS | | P= | P | 7950046 |
HOMEOWNER | PTO | C | 05/30/2023 | PB ok, | JOSEPHD | JOSEPHD | | PTO | C | 7756678 |
HOMEOWNER | PB | C | 05/30/2023 | viewed videos of 2" piping | JOSEPHD | JOSEPHD | | PB | C | 7756675 |
HOMEOWNER | PTO | P | 05/22/2023 | correction made at master shower, can compete pto once PB is done | JOSEPHD | JOSEPHD | | PTO | P | 7750494 |
HOMEOWNER | PB | P | 05/22/2023 | still need to see camera footage of 2" in bathroom group, 3" that was re-piped ok, | JOSEPHD | JOSEPHD | | PB | P | 7750492 |
HOMEOWNER | PB | R | 05/03/2023 | expose all piping, trunk line is holding water, re- inspect all. | TAYLOR | TAYLOR | | PB | R | 7734156 |
HOMEOWNER | PTO | P | 04/28/2023 | still lacking grade at master shower, still need to address PB inspection, other corrections made, note: at final check for support on ejector piping in mech and pit lid depth | JOSEPHD | JOSEPHD | | PTO | P | 7730190 |
HOMEOWNER | PTO | P | 04/26/2023 | need to run ejector to 4 inch, cold water under sized, master shower drain lacking grade, need to anchor basement flange, pit needs to be with in 2 inches of floor or above, need to insulate hot water lines 3/4 and above, there was never an PB inspection for under ground, rest ok note: finished basement, no iirigation, electric water heater, at final need hammer arrestors at washer box, vtr 2 aav @ hall bath lav, basement lav, by mech floor drain | JOSEPHD | JOSEPHD | | PTO | P | 7727799 |
HOMEOWNER | PTO | R | 04/17/2023 | to many items to list, a few items but not all, never had a PB inspection for under floor plumbing, lacking grade thru out, lacking nail protection thru out, nothing on test, cold water piping under sized, re-inspect all | JOSEPHD | JOSEPHD | | PTO | R | 7718123 |
HOMEOWNER | PWO | C | 03/31/2023 | note: will need potable water certification at final | JOSEPHD | JOSEPHD | | PWO | C | 7703880 |
HOMEOWNER | XMS | P | 02/02/2024 | PLAN SPLICE: (No Fee) by: RICHG for Mechanical: REVISED BASEMENT TO FINISH ONE BEDROOM. | RICHG | RICHG | | XMS | P | 7985835 |
HOMEOWNER | XBS | T | 02/02/2024 | PAID (REC#2030647) PLAN SPLICE FEE: $50 by: CHRISTINEH for Construction: Adding additional bedroom in basement | CHRISTINEH | CHRISTINEH | | XBS | T | 7985764 |