MITCHELL WORKZ, LLC | B= | C | 03/31/2023 | Photo of correction on file | CHAD | CHAD | | B= | C | 7703602 |
MITCHELL WORKZ, LLC | B= | P | 03/27/2023 | Missing posted rest room signs --Rest ok -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | CHAD | CHAD | | B= | P | 7698710 |
MITCHELL WORKZ, LLC | BFR | P | 12/09/2022 | Attach mechanical / Pending all other required inspections / Light gauge metal framing OK / Discussed accessible elements / Discussed sink side clearance in restrooms for forward approach, one sink is currently at 13.5" from unfinished wall to centerline | ADAML | ADAML | | BFR | P | 7606122 |
CARDINAL ELECTRIC LLC | E= | C | 02/22/2023 | Corrections made | BRETC | BRETC | | E= | C | 7666804 |
CARDINAL ELECTRIC LLC | ER | C | 02/21/2023 | | BRETC | BRETC | | ER | C | 7666182 |
CARDINAL ELECTRIC LLC | E= | P | 02/21/2023 | Add 2 RTU's A&B to permit / Cannot have exposed THWN in RTU chase, need liquidtight from disconnect to electrical compartment for A&B / RTU-A - 25 amp, RTU-B - 25 amp / Rest - Ok | BRETC | BRETC | | E= | P | 7666174 |
CARDINAL ELECTRIC LLC | E= | P | 02/21/2023 | Upload SCCR letter only | BRETC | BRETC | | E= | P | 7665007 |
CARDINAL ELECTRIC LLC | E= | R | 01/31/2023 | This inspection was not needed at this time. | AARONR | AARONR | | E= | R | 7649557 |
CARDINAL ELECTRIC LLC | ER | P | 01/31/2023 | Above ceiling in front area / office / and 2x bathrooms OK. | AARONR | AARONR | | ER | P | 7649537 |
CARDINAL ELECTRIC LLC | ES | C | 12/09/2022 | Commercial Service: 100 amp 4/wire 480v / Ok to reset meter | BRETC | BRETC | | ES | C | 7606971 |
CARDINAL ELECTRIC LLC | ER | P | 12/09/2022 | All walls only - Ok | BRETC | BRETC | | ER | P | 7606970 |
A & H MECHANICAL, INC. | H= | C | 03/08/2023 | NOTE / CORRECTION MADE / SEE IMAGES / | JERRYF | JERRYF | | H= | C | 7680748 |
A & H MECHANICAL, INC. | HD | P | 03/03/2023 | IMAGES ALREADY RECEIVED OF THESE CORRECTIONS SEND PHOTOS OF THERMOSTATS OR SET ON-SITE INSPECTION | NICKE | NICKE | | HD | P | 7675880 |
A & H MECHANICAL, INC. | H= | P | 03/02/2023 | NO CONTRACTOR ON SITE FOR THERMOSTAT INSPECTION, NO ACCESS TO ADDRESS (MAY ATTACH CLEAR PHOTOS TO PERMIT WITH MEASUREMENTS OF 48" OR LOCK BOX FOR THERMOSTATS). FINAL PENDING-- THERMOSTATS INSTALLED. | PAULO | PAULO | | H= | P | 7675531 |
A & H MECHANICAL, INC. | H= | P | 03/02/2023 | PLAN SPLICE RECEIVED SMOKE DETECTOR SHUTDOWNS INSTALLED BATHROOM DOOR UNDERCUT. WILL SET ON-SITE INSPECTION FOR THERMOSTATS. | NICKE | NICKE | | H= | P | 7674561 |
A & H MECHANICAL, INC. | H= | P | 02/21/2023 | NEED THE FOLLOWING - REVISED PLAN SPLICE PER PREVIOUS NOTES AND EQUIPMENT SCHEDULE - LOCK BOXES ON THERMOSTATS OR LOWER TO 48" TO TOP OF THERMOSTATS - SMOKE SHUTDOWN WITH REMOTE INDICATORS AND AUDIBLE ALARMS AT BOTH UNITS - UNDER CUT RESTROOM DOORS FOR RETURN AIR PATH | JERRYF | JERRYF | | H= | P | 7665717 |
A & H MECHANICAL, INC. | H= | P | 02/21/2023 | WILL NEED ON SITE INSPECTION TO VERIFY ALL NOTES AND REVISED PLAN SPLICE NOTE / TAB REPORT RECEIVED / SEE IMAGES / | JERRYF | JERRYF | | H= | P | 7664824 |
A & H MECHANICAL, INC. | H= | P | 01/27/2023 | SEE HD NOTES FOR FINAL | JERRYF | JERRYF | | H= | P | 7646418 |
A & H MECHANICAL, INC. | HD | P | 01/27/2023 | BEFORE FINAL NEED TO CORRECT PERMIT WORK SCOPE TO 2 NEW RTU'S - 2 EXHAUST FANS - 1 COMMERCIAL DUCT- PLAN SPLICE FOR DUCT WORK CHANGE AND REVISED EQUIPMENT SCHEDULE FOR REPLACING EXISTING RTU'S - TAB REPORT - SMOKE SHUT DOWN AND REMOTE INDICATORS WITH AUDIBLE ALARMS - THERMOSTATS NOTE / ABOVE CEILING SA / RA MAINS / RUN OUTS / GRILLES / FINAL CONNECTIONS / ARE COMPLETE | JERRYF | JERRYF | | HD | P | 7646417 |
WHITCOMB PLUMBING AND HEATING LIMITED | P= | C | 03/14/2023 | P= OK PER PHOTOS ( SEE IMAGES) | LEE | LEE | | P= | C | 7686217 |
WHITCOMB PLUMBING AND HEATING LIMITED | P= | P | 03/10/2023 | INSTALL VAC-RELIEF VALVE AT W/H -- NEED 30" IN FRONT OF ELEMENT FOR SERVICE ACCESS -- OTHER OK | LEE | LEE | | P= | P | 7683807 |
WHITCOMB PLUMBING AND HEATING LIMITED | PTO | C | 11/28/2022 | ok note: cheack water heater and water heater tie-ins at final | ANTHONYT | ANTHONYT | | PTO | C | 7593521 |
A & H MECHANICAL, INC. | XMS | T | 02/22/2023 | PAID (REC#1936487): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised to provide NEW RTU's | JUSTINC | JUSTINC | | XMS | T | 7666883 |