WELLS & WEST GENERAL CONTRACTORS, INC. | B= | C | 05/18/2023 | All other required Final inspections are complete. (This is a computer generated result) | SHAUN | SHAUN | | B= | C | 7747568 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 05/16/2023 | Building final OK pending other finals. Additional Inspections Required (computer generated): NATCO ELECTRIC, INC. Electrical Final Inspection is not Completed yet. | SHAUN | SHAUN | | B= | P | 7745225 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BSP | P | 03/15/2023 | Grid ceiling wires OK | ADAML | ADAML | | BSP | P | 7688511 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 03/01/2023 | Need other rough inspections completed / Frame ok / Discusses accessible elements / | ERIKK | ERIKK | | BFR | P | 7673413 |
NATCO ELECTRIC, INC. | E= | C | 05/18/2023 | ok per pics | BRIAN | BRIAN | | E= | C | 7747567 |
NATCO ELECTRIC, INC. | E= | P | 05/16/2023 | need raceway from j box to the driver j box behind the mirror / pics ok ( 6 ) total / rest ok / | BRIAN | BRIAN | | E= | P | 7745363 |
NATCO ELECTRIC, INC. | ER | P | 03/17/2023 | bathroom ceilings--ok / | BRIAN | BRIAN | | ER | P | 7690892 |
SPECIAL SYSTEMS DESIGN,LLC | E= | C | 03/16/2023 | FIRE ALARM INSPECTION: restrooms hard lids OK | CRAIGS | CRAIGS | | E= | C | 7689042 |
SPECIAL SYSTEMS DESIGN,LLC | ER | C | 03/16/2023 | FIRE ALARM INSPECTION: restrooms hard lids OK | CRAIGS | CRAIGS | | ER | C | 7689041 |
NATCO ELECTRIC, INC. | ER | R | 03/15/2023 | Electrical Rough ok, FA not complete ---------------do not sheetrock--------------- / bathroom hard lids --ok / | BRIAN | BRIAN | | ER | R | 7688031 |
NATCO ELECTRIC, INC. | ER | P | 02/17/2023 | rough in for walls in two new restrooms ok | CHIPO | CHIPO | | ER | P | 7663880 |
NIELSEN MECHANICAL CONTRACTORS, LLC | H= | C | 04/25/2023 | TRANSFER AIR COMPLETE | MARKB | MARKB | | H= | C | 7726674 |
NIELSEN MECHANICAL CONTRACTORS, LLC | H= | P | 04/20/2023 | FINAL PENDING - How is transfer air getting from bathroom into plenum per engineer letter? ENGINEER LETTER RECEIVED FOR TRANSFER AIR - SEE IMAGES | MARKB | MARKB | | H= | P | 7721857 |
NIELSEN MECHANICAL CONTRACTORS, LLC | H= | P | 04/19/2023 | FINAL PENDING - Need engineer to address transfer air for restroom which is currently pulling from new storage room with no communication. Storage room not shown on plans. TEST AND BALANCE REPORT RECEIVED - SEE IMAGES | MARKB | MARKB | | H= | P | 7720343 |
NIELSEN MECHANICAL CONTRACTORS, LLC | H= | P | 04/13/2023 | FINAL PENDING - Complete transfer air for mens restroom for side room. Provide test and balance report. DIFFUSERS COMPLETE. | MARKB | MARKB | | H= | P | 7715301 |
NIELSEN MECHANICAL CONTRACTORS, LLC | HD | P | 03/16/2023 | ABOVE CEILING DUCT - MAIN, BRANCHES AND FLEX INSTALLED PER PLAN SPLICE - OK TO WRAP / Questioning the location of the T-Stat on plans (Location shows inside the women's bathroom / No diffusers or T-Stat at this time | MICHAELM | MICHAELM | | HD | P | 7689188 |
NIELSEN MECHANICAL CONTRACTORS, LLC | HD | P | 03/07/2023 | ABOVE CEILING DUCT - INSTALL DOES NOT MATCH PLANS (Per contractor, splice being submitted) / EXHAUST FAN ON ROOF INSTALLED PER PLAN / Will update notes in AM / Update - EXHAUST FAN LOCATION MOVED, EXHAUST FAN DUCT NOT TO SIZE ON PLANS. TRANSFERS NOT TO SIZE ON PLANS | MICHAELM | MICHAELM | | HD | P | 7679450 |
DRUMMOND PLUMBING LLC | P= | C | 04/25/2023 | | CODYP | CODYP | | P= | C | 7726496 |
DRUMMOND PLUMBING LLC | PTO | C | 04/10/2023 | Okay for tie ins and insulation Note: not ready for final. | DANR | DANR | | PTO | C | 7711107 |
DRUMMOND PLUMBING LLC | PTO | P | 03/17/2023 | Need to see over head insulation on recirc line, Need water heater, Need to see dwv and water tie in, NOTE/ Rest o.k. | CODYP | CODYP | | PTO | P | 7690528 |
DRUMMOND PLUMBING LLC | PTO | P | 03/02/2023 | Need all under floor DWV and H2o / need all piping in Janitors room / need overhead vents for bathrooms competed (only stubbed in corridor) / need insulation all hot and recirc overhead piping / rest okay. Note: Discussed accessible elements. | DANR | DANR | | PTO | P | 7674956 |
DRUMMOND PLUMBING LLC | PTO | P | 03/01/2023 | Need all under floor DWV and H2o / need all piping in Janitors room / need overhead vents for bathrooms competed (only stubbed in corridor) / Women's restroom need accessible toilet DWV and vent installed and need tie in for toilets / need toilet drain tie in for Men's restroom / need insulation all hot and recirc piping / | DANR | DANR | | PTO | P | 7673390 |
NIELSEN MECHANICAL CONTRACTORS, LLC | XMS | T | 03/10/2023 | PAID (REC#1939741) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised layout | JUSTINC | JUSTINC | | XMS | T | 7683892 |
WELLS & WEST GENERAL CONTRACTORS, INC. | XBS | T | 01/30/2023 | PAID (REC#1930037): PLAN SPLICE FEE: $50 by: JUSTINL for Construction: Minor changes to restroom wall framing | JUSTINL | JUSTINL | | XBS | T | 7648108 |