ARCO / MURRAY NATIONAL DENVER, INC. | BE | L | 04/03/2024 | Renewed for No Fee at 4/3/2024 4:09:33 PM | MATTHEWM | MATTHEWM | | BE | L | 8042088 |
ARCO / MURRAY NATIONAL DENVER, INC. | B= | P | 09/29/2023 | Building final OK pending other finals /. Additional Inspections Required (computer generated): BRUCE MECHANICAL OF COLORADO, INC Mechanical Final Inspection is not Completed yet. | ERIKK | ERIKK | | B= | P | 7872819 |
ARCO / MURRAY NATIONAL DENVER, INC. | BFR | P | 08/23/2023 | Copy room hard lid framing ok / Discussed final inspection protocol with site superintendent / | ERIKK | ERIKK | | BFR | P | 7835569 |
ARCO / MURRAY NATIONAL DENVER, INC. | BSP | P | 07/19/2023 | Remainder of interior separation wall gyp screws ok / Hard lid gyp ok / | ERIKK | ERIKK | | BSP | P | 7802415 |
ARCO / MURRAY NATIONAL DENVER, INC. | BSP | P | 05/23/2023 | Gyp screw inspection on office separation walls ok /. | ERIKK | ERIKK | | BSP | P | 7751938 |
ARCO / MURRAY NATIONAL DENVER, INC. | BSP | R | 05/15/2023 | Drywall screw inspection / Not ready for inspection / Field cancelled by Superintendent Bob / | ERIKK | ERIKK | | BSP | R | 7743969 |
ARCO / MURRAY NATIONAL DENVER, INC. | BIN | P | 05/12/2023 | Insulation and one side of gyp ok at all office separation walls / | ERIKK | ERIKK | | BIN | P | 7742905 |
ARCO / MURRAY NATIONAL DENVER, INC. | BFR | P | 05/03/2023 | Need to attach mechanical and plumbing and have inspections -- Interior light gauge frame OK pending other roughs -- Reviewed Accessible Elements | DAKOTAB | DAKOTAB | | BFR | P | 7734674 |
ARCO / MURRAY NATIONAL DENVER, INC. | BSP | P | 04/06/2023 | no site visit / reviewed PPRBD polices and procedures with site rep over the phone | LONNYS | LONNYS | | BSP | P | 7708546 |
BIBLE ELECTRIC, INC. | E= | C | 09/27/2023 | | BRETC | BRETC | | E= | C | 7870054 |
BIBLE ELECTRIC, INC. | E= | P | 09/19/2023 | Need all missing lighting installed through out suite or splice drawings to show future / Cannot have receptacle behind dishwasher, need to be in adjacent cabinet / rest of suite - Ok | BRETC | BRETC | | E= | P | 7860859 |
BIBLE ELECTRIC, INC. | E= | P | 09/15/2023 | East offices and copy room - ok | BRETC | BRETC | | E= | P | 7858033 |
BIBLE ELECTRIC, INC. | E= | P | 09/13/2023 | South offices and open area only - Ok | BRETC | BRETC | | E= | P | 7855408 |
COLORADO ELECTRICAL SYSTEMS, LLC | E= | C | 09/07/2023 | FIRE ALARM INSPECTION: FACP - Extender - Ok | BRETC | BRETC | | E= | C | 7849159 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | C | 09/07/2023 | FIRE ALARM INSPECTION: | BRETC | BRETC | | ER | C | 7849147 |
BIBLE ELECTRIC, INC. | ER | C | 09/05/2023 | Break rm hard lid - Ok | BRETC | BRETC | | ER | C | 7846388 |
BIBLE ELECTRIC, INC. | ER | P | 08/29/2023 | All drop ceilings except for break room hard lid | BRETC | BRETC | | ER | P | 7840578 |
BIBLE ELECTRIC, INC. | ER | P | 08/11/2023 | Open office and outer office ceilings - Ok | BRETC | BRETC | | ER | P | 7824102 |
BIBLE ELECTRIC, INC. | ER | P | 08/10/2023 | Open office ceilings North West - Ok | BRETC | BRETC | | ER | P | 7822759 |
BIBLE ELECTRIC, INC. | ER | P | 08/09/2023 | West outer offices and inner open office ceilings only - Ok | BRETC | BRETC | | ER | P | 7821254 |
BIBLE ELECTRIC, INC. | ER | P | 08/08/2023 | Inner ceiling offices only South - Ok | BRETC | BRETC | | ER | P | 7819861 |
BIBLE ELECTRIC, INC. | ER | P | 07/14/2023 | All hard lids - Ok | BRETC | BRETC | | ER | P | 7798039 |
COLORADO ELECTRICAL SYSTEMS, LLC | ER | P | 06/30/2023 | FIRE ALARM INSPECTION: Ceiling rough OK. | AARONR | AARONR | | ER | P | 7788252 |
BIBLE ELECTRIC, INC. | ER | P | 05/02/2023 | Wall rough OK. --- Need a few walls on north west side of suite still needing inspection. | AARONR | AARONR | | ER | P | 7732871 |
BRUCE MECHANICAL OF COLORADO, INC | H= | P | 04/10/2024 | PER CONVERSATION WITH MECHANICAL CONTRACTOR , BRUCE MECHANICAL WILL BE RECEIVING AN ENGINEERS APPROVED LETTER ACCEPTING THE TEST AND BALANCE REPORT RESULTS. | TREVORH | TREVORH | | H= | P | 8048169 |
BRUCE MECHANICAL OF COLORADO, INC | H= | P | 10/25/2023 | MANY CFM VALUES ARE OUTSIDE OF THE ACCEPTED +/-10 % RE SUBMIT OR PROVIDE AN ENGINEERS STAMPED LETTER APPROVING THE TABB REPORT AS IS. MECHANICAL FINAL PENDING----------------------TEST AND BALANCE REPORT. | TREVORH | TREVORH | | H= | P | 7898542 |
BRUCE MECHANICAL OF COLORADO, INC | H= | P | 09/12/2023 | ALL GRILLS, REGISTERS AND DIFFUSERS INSTALLED PER PLAN, PNEUMATIC THERMOSTATS INSTALLED PER PLAN. MECHANICAL FINAL PENDING-------------------------TEST AND BALANCE REPORT. | TREVORH | TREVORH | | H= | P | 7853529 |
BRUCE MECHANICAL OF COLORADO, INC | H= | P | 09/08/2023 | CONTRACTOR CANCELED VIA TEXT | TREVORH | TREVORH | | H= | P | 7850654 |
BRUCE MECHANICAL OF COLORADO, INC | HD | P | 08/31/2023 | (DUCT ROUGH) ABOVE CEILING, ALL FLEX AND REGISTERS INSTALLED AT FINAL WILL VERIFY GRILLE INSTALLED IN ALL EXPOSED DUCTWORK. ALL CONTROLS ARE PNEUMATIC VERIFY COMPLETION BY FINAL. ALL VAV HIGH SIDE TIE IN OK, OK TO WRAP. TEST AND BALANCE REPORT BY FINAL. | TREVORH | TREVORH | | HD | P | 7843797 |
BRUCE MECHANICAL OF COLORADO, INC | HD | P | 08/23/2023 | STILL NEED HIGH PRESSURE SIDE OF VAV-1 CONNECTED AND SEALED, SAME WITH DDVAV-1 OK TO ATTACH PICTURES AT NEXT REQUEST . ROUND LATERAL RUN OUTS ABOVE CENTER OFFICES 412 THROUGH 420 RAN PER PLAN OK, OK TO WRAP. BY FINAL WILL NEED SCOPE OF WORK CORRECTED. BY FINAL CONTRACTOR WILL NEED TO CORRECT THEIR SCOPE OF WORK. | TREVORH | TREVORH | | HD | P | 7835109 |
BRUCE MECHANICAL OF COLORADO, INC | HD | P | 08/22/2023 | INSPECTION CANCELLED BY CONTRACTOR RESCHEDULED FOR TOMORROW MORNING | TREVORH | TREVORH | | HD | P | 7834243 |
BRUCE MECHANICAL OF COLORADO, INC | HD | P | 07/28/2023 | PLAN SHEET M1 (DUCT ROUGH) ALL ROUGH IN FROM OFFICE 20 TO THE NORTH IS OK ,OK TO WRAP SLOT DIFFUSER INSTALL OK, ALL RELOCATED REGISTERS ARE COMPLETE. ALL EXPOSED DUCT DIFFUSERS WILL BE INSTALLED BY FINAL. HOT AND COLD DECK TERMINAL UNITS HAVE BEEN INSTALLED NEED TO SEE FINAL TIE INS. WHEN COMPLETE. CONTROLS ARE PNEUMATIC VERIFY NEW THERMOSTAT LOCATION BY FINAL. AT NEXT INSPECTION REQUEST WILL VERIFY THE REMAINING DUCT TIE IN'S WHEN READY. NEW TRANSFER AIR OPENINGS NOTE #12 NOT DONE AT THIS TIME , NEW TRANSFER FOR NOTE #11 NOT DONE AT THIS TIME. | TREVORH | TREVORH | | HD | P | 7811340 |
BRUCE MECHANICAL OF COLORADO, INC | HD | P | 07/27/2023 | PER CONVERSATION WITH CONTRACTOR INSPECTION RESCHEDULED FOR TOMORROW. | TREVORH | TREVORH | | HD | P | 7810594 |
KERWIN PLUMBING & HEATING, INC. | P= | C | 09/25/2023 | OK PER PHOTOS (SEE IMAGES) -- NO ON SITE VISIT | LEE | LEE | | P= | C | 7866046 |
KERWIN PLUMBING & HEATING, INC. | P= | P | 09/22/2023 | IMPROPER AIR GAP AT DISHWASHER -- SEND PHOTO OF OTHER HAMMER ARRESTOR AFTER D/W AIR GAP CORRECTED (HANG DRAIN ON STRAIGHT PART OF WYE) | LEE | LEE | | P= | P | 7864482 |
KERWIN PLUMBING & HEATING, INC. | P= | P | 09/20/2023 | VAC-RELIEF NOT PIPED CORRECTLY -- NEED CANDY CANE ATTACHED TO DISHWASHER STANDPIPE FOR PROPER AIR GAP -- NEED TO VERIFY HAMMER ARRESTORS AT DISHWASHER AND ICE MAKER -- Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | LEE | LEE | | P= | P | 7863035 |
KERWIN PLUMBING & HEATING, INC. | PTO | C | 07/14/2023 | DISCUSSED FLOOR DRAIN REQUIREMENTS FOR READY ACCESS AT FINAL -- NEED ALL W/H ASSOCIATED PIPING AT FINAL | LEE | LEE | | PTO | C | 7798411 |
KERWIN PLUMBING & HEATING, INC. | PTO | R | 07/12/2023 | NO PLUMBER ON SITE -- CALL AHEAD CONFIRMED -- ALSO APPEARS NEW FLOOR DRAIN PIPING NOT UNDER TEST -- NEED ESCORT FOR CEILING INSPECTION -- WAIVED RE-INSPECTION FEE -- PIPE INSULATION OK | LEE | LEE | | PTO | R | 7796447 |
KERWIN PLUMBING & HEATING, INC. | PTO | P | 07/06/2023 | WALLS AND UNDER FLOOR OK MINUS FLOOR DRAIN AT 437 BREAK ROOM -- NEED VENT TIE-IN X-2 -- NEED PIPING INSULATION --NEED W/HTRS AND ALL ASSOCIATED PIPING | LEE | LEE | | PTO | P | 7791214 |
BIBLE ELECTRIC, INC. | XES | T | 05/13/2023 | PAID (REC#1969131): PLAN SPLICE FEE: $50 by: RICHG for Electrical: REVISED ELECTRICAL PLANS. | RICHG | RICHG | | XES | T | 7743641 |
ARCO / MURRAY NATIONAL DENVER, INC. | XMS | P | 05/11/2023 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Layout revised | JUSTINC | JUSTINC | | XMS | P | 7741620 |
ARCO / MURRAY NATIONAL DENVER, INC. | XPS | P | 05/10/2023 | PLAN SPLICE: (No Fee) by: SHANEN for Plumbing: Delta 1 revisions: Adjusted sheet P.1. | SHANEN | SHANEN | | XPS | P | 7740968 |
ARCO / MURRAY NATIONAL DENVER, INC. | XBS | T | 05/10/2023 | PAID (REC#1953935) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Floor plan revisions | SHELLEY | SHELLEY | | XBS | T | 7740903 |