CASCADE BUILDERS, LLC | B= | C | 12/05/2023 | | TRENTP | TRENTP | | B= | C | 7935581 |
CASCADE BUILDERS, LLC | BSP | L | 05/12/2023 | Inspection cancelled by contractor (Lindsey) | TRENTP | TRENTP | | BSP | L | 7742737 |
CASCADE BUILDERS, LLC | BFR | P | 05/08/2023 | Changed to BFR / Photos of fireblocking corrections in furred out wall on file, items okay / Complete pending other roughs | TRENTP | TRENTP | | BFR | P | 7737704 |
CASCADE BUILDERS, LLC | BSP | P | 05/08/2023 | Photos of fireblocking on file | TRENTP | TRENTP | | BSP | P | 7737699 |
CASCADE BUILDERS, LLC | BFR | P | 05/03/2023 | Incomplete fireblocking at tops of furred out walls in bathroom and waiting room, will accept photos of corrections uploaded to inspection request / Need to complete other roughs / Rest okay / Discussed smoke and co detector requirements with homeowner | TRENTP | TRENTP | | BFR | P | 7734388 |
J2D ELECTRIC, INC. | E= | C | 10/11/2023 | E= OK ----- 30 AMP STEAM UNIT ------ | GREGM | GREGM | | E= | C | 7884150 |
J2D ELECTRIC, INC. | E= | R | 10/10/2023 | BLANK OFF VANITY LIGHT ----- OUTLETS NEED GFCI ----- COVER STEAMER EQUIPMENT ----- SWITCH FOR DISPOSAL ----- | GREGM | GREGM | | E= | R | 7883033 |
J2D ELECTRIC, INC. | ER | C | 03/09/2023 | bedroom , bathroom , family area | TOMC | TOMC | | ER | C | 7682806 |
TOM JOHNSON, INC. | H= | C | 09/13/2023 | NOTE / Direct vent boiler / Electric air handler / | CASEYM | CASEYM | | H= | C | 7855346 |
TOM JOHNSON, INC. | H= | P | 09/11/2023 | Office lacks proper sized return air path for two supplies installed / NOTE / Direct vent boiler / Electric air Handler / | CASEYM | CASEYM | | H= | P | 7852634 |
TOM JOHNSON, INC. | HRR | C | 05/01/2023 | | MICHAELM | MICHAELM | | HRR | C | 7731287 |
TOM JOHNSON, INC. | HRR | P | 03/09/2023 | Add plumbing to permit, re-call inspection when plumbing contractor has been added / No on-site needed / NOTE / Direct vent boiler / | SAMS | SAMS | | HRR | P | 7683122 |
FATHER DAUGHTER PLUMBING AND DRAIN SERVICE LLC | P= | C | 11/15/2023 | Corrections made / fixtures replaced. | DANR | DANR | | P= | C | 7919420 |
FATHER DAUGHTER PLUMBING AND DRAIN SERVICE LLC | P= | P | 10/17/2023 | CHECKING ON LISTINGS FOR WATER CLOSET / PED LAV FROM MEXICO TOILET IS 2.2 GALLONS PER FLUSH PER INFO PROVIDED ( ALL INFO IN SPANISH ) -- NEED VENTED ACCESS PANEL AT CAT STATION FOR AAV IN WALL | LEE | LEE | | P= | P | 7890053 |
FATHER DAUGHTER PLUMBING AND DRAIN SERVICE LLC | PSP | P | 09/21/2023 | WILL CHECK STEAMER / SHOWER WALL AT FINAL -- PRICE PHISTER VALVES WILL BE INSTALLED PER PLUMBER -- ALSO NEED LISTINGS FOR HAND MADE TOILET AND MATCHING PEDESTAL LAV GETTING READY TO INSTALL MADE IN MEXICO | LEE | LEE | | PSP | P | 7863779 |
FATHER DAUGHTER PLUMBING AND DRAIN SERVICE LLC | PTO | P | 05/02/2023 | STILL VERIFYING LISTING FOR SHOWER VALVE / TOWER -- NEED CAT STATION HOOKED UP -- NEED STEAMER PIPING COMPLETED | LEE | LEE | | PTO | P | 7732878 |
FATHER DAUGHTER PLUMBING AND DRAIN SERVICE LLC | PTO | P | 05/02/2023 | ENTRY FOR CAT WATER STATION SPEC (SEE IMAGES) | LEE | LEE | | PTO | P | 7732574 |
FATHER DAUGHTER PLUMBING AND DRAIN SERVICE LLC | PTO | P | 04/28/2023 | NEED LISTING FOR OWNER SUPPLIED STEAMER / PHONE / SHOWER TOWER -- NEED TEST ON CAT STATION DRAIN -- NEED TEST ON KITCHES SINK DRAIN --NEED SPECS FOR CAT STATION -- NOTES FOR RBD -- AAV AT KITCHEN SINK (MAY NEED ZONING APPROVAL) | LEE | LEE | | PTO | P | 7730574 |