SOLID ROCK CONSTRUCTION, LLC | B= | C | 11/22/2023 | | TRENTP | TRENTP | | B= | C | 7926107 |
SOLID ROCK CONSTRUCTION, LLC | BLA | C | 06/30/2023 | | TRENTP | TRENTP | | BLA | C | 7787385 |
SOLID ROCK CONSTRUCTION, LLC | BIN | C | 06/20/2023 | Will inspect attic and crawlspace insulation at final | TRENTP | TRENTP | | BIN | C | 7776360 |
SOLID ROCK CONSTRUCTION, LLC | BFR | C | 06/20/2023 | Items corrected | TRENTP | TRENTP | | BFR | C | 7776359 |
SOLID ROCK CONSTRUCTION, LLC | BFR | R | 06/14/2023 | 1. Missing ST18 at front porch post / 2. Missing ST12s at E.E. of trusses above bay window in kitchen / 3. Missing ST18s at E.E. of LVL bearing points between addition and existing house / 4. Height of crawlspace from grade to bottom of floor joist exceeds maximum allowable height of 5 ft per 2017 RBC, Observed average height of 5ft 6 in. / Rest of frame okay | TRENTP | TRENTP | | BFR | R | 7771385 |
SOLID ROCK CONSTRUCTION, LLC | BFD | C | 06/14/2023 | BFT and BFN complete | TRENTP | TRENTP | | BFD | C | 7771047 |
SOLID ROCK CONSTRUCTION, LLC | BFT | C | 06/14/2023 | Required paperwork on file | TRENTP | TRENTP | | BFT | C | 7771046 |
SOLID ROCK CONSTRUCTION, LLC | BTR | C | 05/08/2023 | | FERNANDOH | FERNANDOH | | BTR | C | 7738299 |
SOLID ROCK CONSTRUCTION, LLC | BFN | C | 04/25/2023 | Engineer letter for cut foundation on file | TRENTP | TRENTP | | BFN | C | 7725793 |
SOLID ROCK CONSTRUCTION, LLC | BSP | R | 04/14/2023 | Paperwork provided is not engineer stamped and does not mention observation of cut existing foundation | TRENTP | TRENTP | | BSP | R | 7716334 |
SOLID ROCK CONSTRUCTION, LLC | BFN | P | 04/13/2023 | Update letter from engineer for revised foundation design bearing capacity on file / Still need existing foundation cut observation | TRENTP | TRENTP | | BFN | P | 7715016 |
SOLID ROCK CONSTRUCTION, LLC | BFN | P | 04/11/2023 | foundation design on file - open excavation letter states a bearing capacity of 1000 psf and the foundation design requires a bearing capacity of 4000 psf | BRIANB | BRIANB | | BFN | P | 7712385 |
SOLID ROCK CONSTRUCTION, LLC | BFT | P | 04/11/2023 | open excavation letter on file | BRIANB | BRIANB | | BFT | P | 7712372 |
SOLID ROCK CONSTRUCTION, LLC | BFN | P | 03/28/2023 | Need to complete BFT / Need to provide stamped foundation design / Need saw cut at existing garage slab observation per foundation letter on file / Foundation observation on file, no eufer noted | TRENTP | TRENTP | | BFN | P | 7699796 |
SOLID ROCK CONSTRUCTION, LLC | BFT | P | 03/28/2023 | Need to provide soils report/open hole / Footing observation letter on file | TRENTP | TRENTP | | BFT | P | 7699791 |
SOLID ROCK CONSTRUCTION, LLC | BFD | R | 03/24/2023 | Need to complete BFT and BFN / Need to provide soils report/open hole for drain requirements and detail / Observed drain around entire addition with tie in to existing drain, daylight at west side, dampproofing okay | TRENTP | TRENTP | | BFD | R | 7697232 |
L&M HOLDINGS, INC | E= | C | 09/14/2023 | | RANDY | RANDY | | E= | C | 7857252 |
L&M HOLDINGS, INC | ER | C | 06/02/2023 | 100 amp sub-panel , 2 - # 8 CU , 2 - # 10 | TOMC | TOMC | | ER | C | 7761884 |
A & Z MECHANICAL, INC. | H= | C | 09/14/2023 | Electrical inspector to verify electric baseboard heating and electric wall heater(in crawlspace) / Whole house ventilation being achieved through exhaust fan located in bathroom / Whole house ventilation switch located in bathroom / NOTE / Conditioned crawl space / Electric baseboard heat / Minisplit with 2 heads / | CASEYM | CASEYM | | H= | C | 7856769 |
A & Z MECHANICAL, INC. | HRR | C | 06/22/2023 | verify mini-split and crawl space ventilation at final. | JONH | JONH | | HRR | C | 7779058 |
A & Z MECHANICAL, INC. | HRR | P | 06/20/2023 | Provide access to the crawlspace in order to verify required 50 cfm fan is installed / Where is the crawlspace transfer? / Where are the installation instructions for the type 1 hood? What are the cfms for the range hood? / Dryer and bath exhaust termination within 3' of an open-able window / | SAMS | SAMS | | HRR | P | 7776298 |
A & Z MECHANICAL, INC. | HRR | P | 06/09/2023 | not ready for rough inspection/ | JONH | JONH | | HRR | P | 7768139 |
C&M PLUMBING LLC | P= | C | 08/14/2023 | | LEE | LEE | | P= | C | 7825751 |
C&M PLUMBING LLC | PTO | C | 06/14/2023 | ENTRY FOR DOMESTIC HOT WATER PIPE INSULATION (SEE IMAGES) | LEE | LEE | | PTO | C | 7770858 |
C&M PLUMBING LLC | PTO | P | 05/10/2023 | NEED 3/4" HOT INSULATED -- OTHER OK -- NOTES FOR RBD -- AAV AT KITCHEN -- G.C TO GET MECH / ELECTRICAL TO ATTACH -- | LEE | LEE | | PTO | P | 7740588 |