HOMEOWNER | B= | C | 05/15/2023 | Observed corrections | DOUGC | DOUGC | | B= | C | 7743939 |
HOMEOWNER | B= | P | 05/05/2023 | still need to post IBTS paperwork - observed electronically on site / both exterior stairs missing 36" landings at bottom - stair riser height varies more that 3/8" top of both stairs / missing graspable handrail on one side both sets of stairs / rest OK pending other required inspections -- Schedule a new Building Final when above items are complete. | LONNYS | LONNYS | | B= | P | 7736807 |
PRINDLE MOBILE HOME SERVICES, LLC | BTD | C | 07/18/2022 | straps, piers, spacing and Xi2 okay. State Insignia 2022-15020 on electric panel. wall at north bedrooms need to be reinstalled or engineer letter for removal needed. | NATHAN | NATHAN | | BTD | C | 7690487 |
PRINDLE MOBILE HOME SERVICES, LLC | BVM | C | 06/21/2022 | Serial # 10927A/B okay at frame need IBTS paperwork mounted in home by final. | NATHAN | NATHAN | | BVM | C | 7690486 |
PRINDLE MOBILE HOME SERVICES, LLC | BTD | R | 06/07/2022 | lot not crowned under home, gap at marriage line over 1" at west side of home and needs sealed. | NATHAN | NATHAN | | BTD | R | 7690485 |
PRINDLE MOBILE HOME SERVICES, LLC | BVM | R | 06/07/2022 | IBTS paperwork only states HUD # and there is no HUD tags on units due to newer siding installed. Verification of unit cannot be made. look for serial # at front frame and expose if possible. | NATHAN | NATHAN | | BVM | R | 7690484 |
ALPHA & OMEGA ELECTRICAL SERVICES, LLC | E= | C | 01/09/2023 | ok per pic / | BRIAN | BRIAN | | E= | C | 7690490 |
ALPHA & OMEGA ELECTRICAL SERVICES, LLC | ES | C | 08/24/2022 | Mobile Home Meter Set: 100 amp 3-w---ok to set meter / RBD NOTE need to verify concrete pad for final | BRIAN | BRIAN | | ES | C | 7690488 |
ALPHA & OMEGA ELECTRICAL SERVICES, LLC | EUG | C | 08/24/2022 | from ped to home---note contractor stated it will be under concrete for final it is only 6" to top of conduit now / need to attach to temp set permit / | BRIAN | BRIAN | | EUG | C | 7690489 |
HOMEOWNER | HO= | C | 05/03/2023 | CORRECTIONS MADE | SEANM | SEANM | | HO= | C | 7734470 |
ADLM INC | HO= | P | 05/01/2023 | PARTIALED FOR FURTHER RESEARCH / CHANGED TO HO= / DRYER VENT TO TERMINATE OUTSIDE OF STRUCTURE / 1 INCH MAIN / PRESSURE TEST COMPLETED PREVIOUSLY / 1 RANGE / 1 WATER HEATER / 1 FURNACE / 1 FUTURE FIREPLACE/GAS LOG / (WILL NEED SEPARATE PERMIT FOR GAS LOG WHEN INSTALLED) / NOTE / MANUFACTURED HOME DIRECT VENT FURNACE / MANUFACTURED HOME DIRECT VENT WATER HEATER / | SEANM | SEANM | | HO= | P | 7732052 |
HOMEOWNER | PO= | C | 05/02/2023 | ok | TREBORB | TREBORB | | PO= | C | 7733619 |
AFFORDABLE SERVICES CORP. | PO= | P | 04/28/2023 | Lost test | CODYP | CODYP | | PO= | P | 7730719 |
AFFORDABLE SERVICES CORP. | PO= | R | 04/25/2023 | Need water heater installation instructions on site to verify venting as per previous inspection, Need standing water test on dwv as per previous inspection, NOTE/ Rest o.k. for plumbing | CODYP | CODYP | | PO= | R | 7726668 |
AFFORDABLE SERVICES CORP. | PO= | P | 03/22/2023 | need manufactured home water heater approved vent / need standing water test at dwv piping / need to support dwv every 4 ft / re-inspect all | ANTHONYT | ANTHONYT | | PO= | P | 7694616 |