SUNSET DREAM HOMES, INC | B= | C | 09/16/2024 | Items corrected | TRENTP | TRENTP | | B= | C | 8211759 |
SUNSET DREAM HOMES, INC | B= | P | 09/06/2024 | Temp CO: Pending finals ( Expires: 10/06/2024) | WEBSITE | WEBSITE | | B= | P | 8202694 |
SUNSET DREAM HOMES, INC | B= | P | 09/06/2024 | Need to provide even walking surface for rear garage service door landing / Guards added at retaining wall next to deck landing allow the passage of more than a 4 inch sphere / Rest corrected -- Schedule a new Building Final when above items are complete. | TRENTP | TRENTP | | B= | P | 8202615 |
SUNSET DREAM HOMES, INC | BSP | P | 08/22/2024 | FX approval letter for 2017 permits on file | SHAUN | SHAUN | | BSP | P | 8187538 |
SUNSET DREAM HOMES, INC | BSP | P | 08/22/2024 | uploaded FX certificate of compliance expired 12-01-2021, provide updated certificate of compliance/ FX application certification on file/ FX ES report on file/ update- FX lumber guard OK for 2017 permits | SHAUN | SHAUN | | BSP | P | 8187531 |
SUNSET DREAM HOMES, INC | BSP | P | 08/22/2024 | engineers observation for retaining wall on file | SHAUN | SHAUN | | BSP | P | 8187507 |
SUNSET DREAM HOMES, INC | BSP | P | 08/22/2024 | blower door on file | SHAUN | SHAUN | | BSP | P | 8187501 |
SUNSET DREAM HOMES, INC | B= | R | 08/21/2024 | 1. Need to provide air leakage test results / 2. Missing code compliant address numbers on house / 3. Need to provide design professional observation of retaining wall at northwest corner of house / 4. Window in bathroom next to front entrance missing safety glazing, window is less than 60 inches from waters edge of tub and less than 60 inches in height for tub standing surface / 5. Missing code compliant handrails at rear deck stairs / 6. Missing code compliant landing at bottom of deck stairs / 7. Missing code compliant landing at north side of deck / 8. More than 30 inches of fall within 36 inches of north deck landing walking surface / 9. Need to provide final approved certificates and test report for materials used in fire protection of floor per IRC 302.13 EX #4 / Finished basement, rear deck w/stairs, AC. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | TRENTP | TRENTP | | B= | R | 8186572 |
SUNSET DREAM HOMES, INC | BLA | C | 07/19/2024 | Lath okay per previous observation and framing letter on file | TRENTP | TRENTP | | BLA | C | 8152242 |
SUNSET DREAM HOMES, INC | BSP | P | 07/19/2024 | Engineer observation for front and rear cover frames and deck frame on file | TRENTP | TRENTP | | BSP | P | 8152238 |
SUNSET DREAM HOMES, INC | BLA | R | 07/18/2024 | No inspection history on file for inspection of front/rear cover posts and deck frame prior to being covered with sheathing and lath per inspection note on 1/24/24, will need to expose for inspection or provide observation letter by licensed design professional prior to lath | TRENTP | TRENTP | | BLA | R | 8151477 |
SUNSET DREAM HOMES, INC | BSP | P | 07/08/2024 | Engineer letter on file for deck piers | TRENTP | TRENTP | | BSP | P | 8139276 |
SUNSET DREAM HOMES, INC | BIN | C | 01/31/2024 | | BRIANB | BRIANB | | BIN | C | 7982681 |
SUNSET DREAM HOMES, INC | BFR | C | 01/31/2024 | observed corrections from previous inspection | BRIANB | BRIANB | | BFR | C | 7982677 |
SUNSET DREAM HOMES, INC | BSP | P | 01/31/2024 | Engineer letter on file for framing modifications / | ERIKK | ERIKK | | BSP | P | 7982295 |
SUNSET DREAM HOMES, INC | BFR | R | 01/24/2024 | 1. Need design professional clarification of location changes of garage windows from rear wall to east and west walls / 2. Missing blocking at garage door brackets / 3. Missing roof jack for B vent for dry in / 4. Need clarification for use of hangers with titen screws in place of beam pockets of LVL beams at stair opening / 5. Hangers missing shear nails at front porch double beam / Rear cover lid okay // Note: Still need to inspect deck frame and front and rear porch posts as BSP at later date / Need fire protection of floor material installation certificate and test report by final | TRENTP | TRENTP | | BFR | R | 7976294 |
SUNSET DREAM HOMES, INC | BLA | P | 11/29/2023 | Lath for house okay, inspection comment states lath to be done on deck columns at later date | TRENTP | TRENTP | | BLA | P | 7930099 |
SUNSET DREAM HOMES, INC | BFI | C | 10/09/2023 | Engineer observation of foundation insulation on file | ANGELW | ANGELW | | BFI | C | 7881144 |
SUNSET DREAM HOMES, INC | BFI | R | 10/06/2023 | No foundation insulation observed | ANGELW | ANGELW | | BFI | R | 7880634 |
SUNSET DREAM HOMES, INC | BFD | C | 10/06/2023 | Soils report on file / Engineer observation of foundation drain and damp proofing on file | ANGELW | ANGELW | | BFD | C | 7879743 |
SUNSET DREAM HOMES, INC | BFT | C | 10/05/2023 | open hole on file -- 3000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | ANGELW | ANGELW | | BFT | C | 7878291 |
SUNSET DREAM HOMES, INC | BFN | C | 10/05/2023 | open hole on file -- 3000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | ANGELW | ANGELW | | BFN | C | 7878289 |
SUNSET DREAM HOMES, INC | BFN | P | 10/04/2023 | Provide foundation design with verifiable bearing pressure / open hole on file -- 3000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / | ANGELW | ANGELW | | BFN | P | 7875910 |
SUNSET DREAM HOMES, INC | BFT | P | 10/04/2023 | Provide foundation design with verifiable bearing pressure / open hole on file -- 3000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / | ANGELW | ANGELW | | BFT | P | 7875909 |
SUNSET DREAM HOMES, INC | BFT | P | 09/12/2023 | Changed to BFT / Still need footing observation / Soils report on file | TRENTP | TRENTP | | BFT | P | 7853307 |
SUNSET DREAM HOMES, INC | BFD | P | 09/12/2023 | Need to complete BFT and BFN / Engineer letter for perimeter drain on file -- Damp proofing noted / Only last two pages of soils report provided, need to provide full soils report | TRENTP | TRENTP | | BFD | P | 7853102 |
SUNSET DREAM HOMES, INC | BFT | P | 09/12/2023 | Need to provide footing observation and full soils report, only last two pages of report provided / Open hole on file, 3000 - usable - 10% / Note: Need to complete BFN | TRENTP | TRENTP | | BFT | P | 7853098 |
SUNSET DREAM HOMES, INC | BFI | P | 03/27/2023 | AUTHORIZED INSPECTION BY ENGINEER | JACKIEP | JACKIEP | JACKIEP | BFI | P | 7698467 |
SUNSET DREAM HOMES, INC | BFD | P | 03/27/2023 | AUTHORIZED INSPECTION BY ENGINEER | JACKIEP | JACKIEP | JACKIEP | BFD | P | 7698466 |
SUNSET DREAM HOMES, INC | BFT | P | 03/27/2023 | AUTHORIZED INSPECTION BY ENGINEER | JACKIEP | JACKIEP | JACKIEP | BFT | P | 7698465 |
SUNSET DREAM HOMES, INC | BFN | P | 03/27/2023 | AUTHORIZED INSPECTION BY ENGINEER | JACKIEP | JACKIEP | JACKIEP | BFN | P | 7698464 |
LENZ ELECTRIC, INC. | E= | C | 05/31/2024 | | RANDY | RANDY | | E= | C | 8103394 |
LENZ ELECTRIC, INC. | E= | R | 05/30/2024 | LAUNDRY AREA NEEDS GFCI ----- REST OK ----- 25 AMP A/C ---- | GREGM | GREGM | | E= | R | 8101574 |
LENZ ELECTRIC, INC. | E= | R | 05/17/2024 | a/c 25 amp max 30 amp breaker installed, no power to receptacle in a/c disconnect if not used remove and blank off, what circuits feed exterior receptacles all 20 amp receptacles on 15 amp circuit?, all finished area basement receptacles must be gfci protected, all unfinished need gfci protection, cannot have open lamp in storage close t under stairs , receptacle spacing kitchen counter top by mud room, gfci protect all receptacle in laundry area, install blocking to protect cables in unfinished areas, open box in garage above water, complete re-inspect | BRET | BRET | | E= | R | 8087542 |
LENZ ELECTRIC, INC. | ES | C | 02/12/2024 | Residential Underground: 200-amp 3 Wire New Residence ok NEED METER SEAL / | GREGM | GREGM | | ES | C | 7993334 |
LENZ ELECTRIC, INC. | ES | R | 02/09/2024 | ufer gec must land on neutral bar of disconnect install bond jumpers that are provided to bond system | BRET | BRET | | ES | R | 7992446 |
LENZ ELECTRIC, INC. | ES | R | 01/19/2024 | Residential Underground: NOT READY ----- | GREGM | GREGM | | ES | R | 7972064 |
LENZ ELECTRIC, INC. | ER | C | 01/19/2024 | ER OK ------ #1 TO SUB PANEL --- #6CU RANGE BASEMENT----- REV UFER ---- NO MCC --- #10 A/C COOK TOP MAIN LEVEL -----P | GREGM | GREGM | | ER | C | 7972062 |
LENZ ELECTRIC, INC. | EUG | C | 08/21/2023 | 4/0 urd | TOMC | TOMC | | EUG | C | 7832122 |
GENE'S HEATING AND AIR LLC | H= | C | 05/16/2024 | Electric panel located inside mechanical room. | SAMS | SAMS | | H= | C | 8086594 |
GENE'S HEATING AND AIR LLC | H= | P | 04/24/2024 | NEED 2-LB LETTER FROM GAS PURVEYOR / MISSING MEDIUM PRESSURE STICKERS ON HOUSE RISER / INSTALL THE FURNACE 120V SWITCHES (X2) / CONTRACTOR TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST ONCE THE 2-LB LETTER HAS BEEN ATTACHED. Whole house ventilation being achieved through exhaust fan located in powder room / NOTE / Finished basement / Direct vent furnace x2 / Outside air with damper to furnace return x2 / A/C complete / Mechanical room meets 50 to 1 for combustion air / | BILLS | BILLS | | H= | P | 8063036 |
GENE'S HEATING AND AIR LLC | H= | P | 04/16/2024 | 2LB LETTER OF APPROVAL IS REQUIRED / MISSING MEDIUM PRESSURE STICKERS ON HOUSE RISER / MISSING BOTH FURNACE TERMINATIONS (Ensure they are a minimum of 12'' above grade) / INSTALL THE FURNACE GAS GROMMETS (X2) / INSTALL THE FURNACE 120V SWITCHES (X2) / LABEL WHOLE HOUSE VENTILATION SWITCH / OK TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST / Whole house ventilation being achieved through exhaust fan located in powder room / NOTE / Finished basement / Direct vent furnace x2 / Outside air with damper to furnace return x2 / A/C complete / Mechanical room meets 50 to 1 for combustion air / | SAMS | SAMS | | H= | P | 8053996 |
O.M.A.G.M., INC. | HC | C | 01/30/2024 | RELEASE 2 LB METER | SAMS | SAMS | | HC | C | 7981595 |
O.M.A.G.M., INC. | HO | C | 01/30/2024 | OK TO COVER / By final provide the 2 lb letter of approval and install the regulators and medium pressure stickers / 10 lb test ok / Added 90' of 3/4'' PE with tracer wire from meter to house / | SAMS | SAMS | | HO | C | 7981592 |
GENE'S HEATING AND AIR LLC | HC | C | 01/05/2024 | RELEASE METER | SAMS | SAMS | | HC | C | 7961100 |
GENE'S HEATING AND AIR LLC | HRR | C | 01/05/2024 | | SAMS | SAMS | | HRR | C | 7961098 |
GENE'S HEATING AND AIR LLC | HRR | P | 01/03/2024 | Multiple supply and return ducts undersized, install per plan / Verify furnace vent terminations clearance to grade at final / Whole house ventilation being achieved through exhaust fan located in powder room / Verify whole house ventilation switch location at final / NOTE / Finished basement / Outside air with damper to furnace return x 2 / Direct vent furnace x 2 / A/C rough, coil and lineset. x 1 / | CASEYM | CASEYM | | HRR | P | 7958899 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 12/19/2023 | Need 2lb approval letter from gas provider by final / Verify one regulator in north mechanical room and one regulator in south mechanical room at final / Verify medium pressure stenciling on all exposed gas line at final /
10 lb test ok / 3/4 inch main / 2 x furnace / 1 water heater / 2 x range / 2 x fireplace / One 1/2" stub at north wall for 60K BBQ / | CASEYM | CASEYM | | HI | C | 7949113 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 12/05/2023 | Main level fireplace clearance to combustibles and vent termination ok. / Non-combustible materials installed / Basement fireplace clearance to combustibles and vent termination ok. / Non-combustible materials installed / | CASEYM | CASEYM | | HV | C | 7935474 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 05/10/2024 | Certificate of potable water uploaded to permit | FRANKM | FRANKM | | P= | C | 8080382 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 12/19/2023 | THREE VTR -- AAV @ BAR -- DRAFT HOOD W/H | LEE | LEE | | PTO | C | 7949087 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB+ | C | 12/13/2023 | FLOOR DRAIN AT NEW WATER HEATER LOCATION OK | LEE | LEE | | PB+ | C | 7944181 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 09/19/2023 | | LEE | LEE | | PWO | C | 7861324 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | P | 09/14/2023 | CONNECTION AT WELL HEAD INCOMPLETE -- NEED PRESSURE TEST OR UNCOVER ALL PIPE IN DITCH | LEE | LEE | | PWO | P | 7856908 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 09/14/2023 | HDPE STUBBED IN THRU WALL | LEE | LEE | | PB | C | 7856904 |
SUNSET DREAM HOMES, INC | XMS | T | 01/04/2024 | PAID (REC#2021927): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: some duct sizes changed | TCRIPPEN | TCRIPPEN | | XMS | T | 7960121 |
SUNSET DREAM HOMES, INC | XMS | T | 01/04/2024 | PAID (REC#2021927): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: Some duct sizes changed. | TCRIPPEN | TCRIPPEN | | XMS | T | 7960114 |
SUNSET DREAM HOMES, INC | XMS | T | 12/29/2023 | PAID (REC#2020760): PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: new splice for duct design | TCRIPPEN | TCRIPPEN | | XMS | T | 7956253 |