AVA'S CONSTRUCTION LLC | BSP | P | 04/29/2024 | site visit to review smoke partition infill at new door replacement / reviewed building final inspection requirements | LONNYS | LONNYS | | BSP | P | 8067499 |
AVA'S CONSTRUCTION LLC | BLA | P | 02/29/2024 | west laundry lath OK | LONNYS | LONNYS | | BLA | P | 8009856 |
AVA'S CONSTRUCTION LLC | BFR | P | 12/06/2023 | remaining wall framing OK in laundry room door infills | LONNYS | LONNYS | | BFR | P | 7936884 |
AVA'S CONSTRUCTION LLC | BFR | P | 11/16/2023 | still need to inspect door infill and door reduction framing when ready / rest of laundry interior light gauge steal wall framing OK pending other required inspections | LONNYS | LONNYS | | BFR | P | 7920557 |
AVA'S CONSTRUCTION LLC | BE | L | 10/03/2023 | Renewed online for Half Fee at Oct 3 2023 8:15AM (RECEIPT #: 1994316) | WEBSITE | WEBSITE | | BE | L | 7874708 |
EL PASO ELECTRIC, LLC. | E= | C | 04/10/2024 | ok per pic | BRIAN | BRIAN | | E= | C | 8047718 |
EL PASO ELECTRIC, LLC. | E= | P | 04/09/2024 | still need panel ID and where it feeds from / upload pics | BRIAN | BRIAN | | E= | P | 8046612 |
EL PASO ELECTRIC, LLC. | ER | C | 04/03/2024 | ceiling--ok | BRIAN | BRIAN | | ER | C | 8041363 |
EL PASO ELECTRIC, LLC. | E= | P | 04/03/2024 | need good pics of the panels being labeled / both panels feed with 50 amp 3 pole breakers / | BRIAN | BRIAN | | E= | P | 8041360 |
KING ELECTRIC SERVICES, LLC | E= | R | 01/30/2024 | need to verify breakers feeding new panels ,. breakers meet AIC ratings for new panels and panels schedules / plans show panels schedules w/ 100A breaker feeding new panels, one line show 70A breaker breaker feeding new panel and note stating 50A breaker feeding new panels / | MIGUEL | MIGUEL | | E= | R | 7981553 |
KING ELECTRIC SERVICES, LLC | ER | C | 01/30/2024 | permit being transferred ahead of completion of above ceiling. new contractor to be responsible for above ceiling rough per GC / | MIGUEL | MIGUEL | | ER | C | 7981546 |
KING ELECTRIC SERVICES, LLC | ER | P | 11/13/2023 | washer and dryer outlets in walls ok / ceiling has been demoed and will need an above ceiling inspection when re-installed / | MIGUEL | MIGUEL | | ER | P | 7916615 |
BLUE PHOENIX MECHANICAL, LLC | HSP | P | 04/30/2024 | CRD INSPECTION: SUPPORT FOR THE NAILOR 0700 IS NOT INSTALLED PER INSTALLATION INSTRUCTIONS & IN REVIEW. | PAULO | PAULO | | HSP | P | 8069404 |
BLUE PHOENIX MECHANICAL, LLC | HSP | P | 04/05/2024 | HAD DISCUSSION WITH MECHANICAL CONTRACTOR (Hampton/Blue Phoenix) about existing CRD's that were re-installed after drop ceiling grid (RATED CEILING) was removed & replaced & some CRD's (7/like) were replaced with other CRD's from another portion of the building because of non-operational use, WILL NEED REVISED PLANS TO SHOW EXISTING CRD's & NOTES PERTAINING TO THEM, WILL NEED INSTALLATION INSTRUCTIONS FOR EXISTING & REPLACED CRD's FOR PROPER INSPECTION OF INSTALLATION. | PAULO | PAULO | | HSP | P | 8043759 |
BLUE PHOENIX MECHANICAL, LLC | HSP | P | 04/04/2024 | HAD A CONSULTATION WITH MECHANICAL CONTRACTOR FOR MOVING FORWARD WITH PROJECT ON DRYER EXHAUST DUCTS WITH TERMINATIONS & CLEARANCES, ENGINEER TO CLARIFY NOTE #6 FOR REGULATORS FOR DRYERS ON A LOW PRESSURE SYSTEM, ALL FINAL GAS CONNECTIONS & SUPPORT ON GAS LINE FROM MAIN REGULATOR TO ROOF PENETRATION OF LAUNDRY ROOM, REVIEWING EXISTING CRD's & REPLACED CRD's (MOVED FROM OTHER ROOMS) & WILL UPDATE WHEN FINISHED. | PAULO | PAULO | | HSP | P | 8043449 |
BLUE PHOENIX MECHANICAL, LLC | HSP | P | 04/04/2024 | HAD CONVERSATION WITH PREVIOUS INSPECTOR ABOUT GAS, VENTING, AND MUA. HE WILL BE ONSITE TODAY | SEANM | SEANM | | HSP | P | 8042448 |
BLUE PHOENIX MECHANICAL, LLC | HI | P | 04/03/2024 | PREVIOUSLY INSPECTED / REGULATORS ARE IN PLACE | SEANM | SEANM | | HI | P | 8041453 |
BLUE PHOENIX MECHANICAL, LLC | HD | P | 04/03/2024 | UNABLE TO VERIFY DRYER TERMINATIONS WILL NEED TO CONSULT ORIGINAL INSPECTOR / FIRE DAMPERS ARE IN PLACE AT SUPPLIES / WILL UPDATE NOTES IN THE AM | SEANM | SEANM | | HD | P | 8041452 |
DR. HYDRONIC ENGINEERING, LLC | H= | R | 11/02/2023 | CONTRACTOR HAS NO WORK AFFILIATED WITH THIS PERMIT, MAY VOID PERMIT IF NO WORK IS DONE UNDER CONTRACTOR #24140. INSPECTION FOR DRYER EXHAUST DUCTS FOR THIS CONTRACTOR (#24140) IS UNDER PERMIT #O11827 & WILL NEED TO BE ATTACHED FOR INSPECTION & INSPECTION NOTES. WILL NEED TO TRANSFER THESE NOTES & NOTES FROM 8/11/23 TO PERMIT #011827 WHEN ATTACHED. Note / Dryer Exhaust duct installation & termination ok x5. | PAULO | PAULO | | H= | R | 7907291 |
TECHNOTHERM HVAC LLC | HD | P | 11/01/2023 | GOOSE NECKS FOR DRYER EXHAUST DUCTS & COUPLINGS FOR DRYER EXHAUST DUCTS IN REVIEW & WILL UPDATE CONTRACTOR WHEN FINISHED. | PAULO | PAULO | | HD | P | 7906053 |
TECHNOTHERM HVAC LLC | HD | P | 10/24/2023 | NOT READY FOR FINAL, CHANGE TO HD, STILL NEED MAKE UP AIR, DAMPERS, DRYER EXHAUST DUCT, ECT.... INSPECTIONS. | PAULO | PAULO | | HD | P | 7897490 |
TECHNOTHERM HVAC LLC | HC | C | 10/24/2023 | OK. | PAULO | PAULO | | HC | C | 7897477 |
TECHNOTHERM HVAC LLC | HI | C | 10/24/2023 | 10 lb test ok / ENGINEER TO CLARIFY NOTE #6 FOR INSTALLATION OF REGULATORS AT FINAL ON A LOW PRESSURE SYSTEM.
Note / All gas piping installed per plans (LOW PRESSURE SYSTEM PER SHEET M2.01/M2.02/M2.04 & M6.00A). | PAULO | PAULO | | HI | C | 7897473 |
TECHNOTHERM HVAC LLC | HI | P | 10/16/2023 | NO PRESSURE TESTS AT THIS TIME. ENGINEER TO CLARIFY NOTE #6 FOR INSTALLATION OF REGULATORS ON A LOW PRESSURE SYSTEM. CONTRACTOR- WILL NEED SERVICE ACCESS FOR OUTSIDE AIR DAMPER MOTORS AT FINAL. Note / All gas piping installed per plans (LOW PRESSURE SYSTEM PER SHEET M6.00A). | PAULO | PAULO | | HI | P | 7889216 |
TECHNOTHERM HVAC LLC | HI | P | 09/26/2023 | NOT READY, TEST PRESSURE TO EXCLUDE REGULATORS AS THEY ARE NOT EQUIPPED FOR THAT PRESSURE, MULTIPLE LINES NOT TESTED DUE TO ISOLATION VALVES IN THE OFF POSITION, NOTE #6 CALLS FOR ALL REGULATORS TO BE AT EQUIPMENT CONNECTION, PLANS CALL FOR 11 DRYER DROPS TO BE ON THE 2" LINE (ONLY 10 INSTALLED). RE-INSPECT ALL. | PAULO | PAULO | | HI | P | 7868479 |
DR. HYDRONIC ENGINEERING, LLC | HD | R | 08/11/2023 | CONTRACTOR CLAIMS NO WORK ON THIS PERMIT, NEW WORK FOR THIS CONTRACTOR (#24140) IS ON PERMIT #O11827. North Wing- NEED LICENSED CONTRACTOR TO CLAIM FIRE DAMPER (M2.01D/ENLARGED ROOM DETAIL/NOTE #7). Level 1 M2.01D through M2.03D- Note / 5 Dryer Exhaust ducts & terminations ok. | PAULO | PAULO | | HD | R | 7824211 |
TRANE U.S. INC. | HSP | P | 07/17/2023 | Received Installation Instructions for Trane Chiller (SEE IMAGES/IN REVIEW & WILL UPDATE). CONTRACTOR TO CALL PERMIT COUNTER OF PPRBD AND REMOVE THE CHILLER FROM THE REMODEL PERMIT TO A STAND ALONE CHANGE OUT PERMIT AND ADD 1 CONDENSER TO THE SCOPE OF WORK. | PAULO | PAULO | | HSP | P | 7799114 |
TRANE U.S. INC. | HSP | P | 07/13/2023 | CONTRACTOR TO CALL PERMIT COUNTER OF PPRBD AND REMOVE THE CHILLER FROM THE REMODEL PERMIT TO A STAND ALONE CHANGE OUT PERMIT AND ADD 1 CONDENSER TO THE SCOPE OF WORK. NEED INSTALLATION INSTRUCTIONS FOR CHILLER (CONTRACTOR WILL BE EMAILING INSTALLATION INSTRUCTIONS FOR CHILLER). | PAULO | PAULO | | HSP | P | 7796629 |
TRANE U.S. INC. | H= | P | 07/12/2023 | REVIEWING CONTRACTOR ON OPEN REMODEL PERMIT FOR CHILLER & CONDENSER CHANGE OUT, ADD CONDENSER TO THE SCOPE OF WORK AND INSTALLATION INSTRUCTIONS BEING EMAILED FOR CHILLER. WILL UPDATE NOTES WHEN FINISHED. | PAULO | PAULO | | H= | P | 7796127 |
VENTRY ASSET MANAGEMENT LLC | PTO | C | 08/24/2023 | | CODYP | CODYP | | PTO | C | 7836121 |
VENTRY ASSET MANAGEMENT LLC | PTO | R | 08/22/2023 | Trip fee waived this time only, Missing top plate at washer box vent ion right corner, Missing support on water piping through out, Missing support on multiple washer boxes | CODYP | CODYP | | PTO | R | 7833227 |
VENTRY ASSET MANAGEMENT LLC | PTO | P | 08/03/2023 | Missing support and nail protection throughout NOTE/ dwv and water piping test o.k. | CODYP | CODYP | | PTO | P | 7816609 |
VENTRY ASSET MANAGEMENT LLC | PB | P | 06/30/2023 | Still need plan revision, NOTE/ Rest o.k. for underground | CODYP | CODYP | | PB | P | 7787272 |
VENTRY ASSET MANAGEMENT LLC | PB | P | 06/28/2023 | Need to have on proper test before plumbing inspector arrives, Need plan splice for cell core pvc being installed, NOTE/ Rest o.k. | CODYP | CODYP | | PB | P | 7784988 |
VENTRY ASSET MANAGEMENT LLC | PB | P | 06/16/2023 | Need plan revision showing material being installed, Need installation instructions for bands used at tie in location, Properly bed pipe remove large rocks and concrete from trench, Lacking proper grade throughout, Need to re test piping due to test failing before inspection, Re inspect all | CODYP | CODYP | | PB | P | 7773746 |
KING ELECTRIC SERVICES, LLC | XES | P | 02/29/2024 | PLAN SPLICE: (No Fee) by: SHELBY for Electrical: Revision to panel load summary and j box location | SHELBY | SHELBY | | XES | P | 8010452 |
VENTRY ASSET MANAGEMENT LLC | XPS | T | 07/13/2023 | PAID (REC#1975233): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Revised sheet P7.00. | SHANEN | SHANEN | | XPS | T | 7796703 |