KROESCHELL ROCKY MOUNTAIN, INC | B= | C | 12/08/2023 | per inspector AdamL, no additional site visit needed, Building final ok with mech splice | JOHN | JOHN | | B= | C | 7939590 |
KROESCHELL ROCKY MOUNTAIN, INC | B= | R | 11/10/2023 | Can not perform final until Mechanical completes their review for CRDs in bathrooms as this is a rated ceiling assembly / ,Discussed issues on site with Super. Additional Inspections Required (computer generated): HEATING & PLUMBING ENGINEERS, INC Mechanical Final Inspection is not Completed yet, HEATING & PLUMBING ENGINEERS, INC Plumbing Final Inspection is not Completed yet. | ADAML | ADAML | | B= | R | 7915171 |
KROESCHELL ROCKY MOUNTAIN, INC | BSP | P | 09/07/2023 | Rm 238 - Drywall OK on bathroom lid | ADAML | ADAML | | BSP | P | 7849655 |
KROESCHELL ROCKY MOUNTAIN, INC | BSP | P | 09/05/2023 | Room 338 - Drywall OK on rated walls and ceilings / Room 238 - Still need to see ceiling in bathroom / All walls and remaining ceilings OK | ADAML | ADAML | | BSP | P | 7846832 |
KROESCHELL ROCKY MOUNTAIN, INC | BSP | P | 08/23/2023 | Existing ceilings have been removed over both units so you need to provide a splice with a 1 hour horizontal assembly ( 12 A2.1 states that the existing ceiling assembly is a UL L501 however, that has been removed )Do not cover any ceilings prior to splice and inspections for assembly / Drywall screws on W5 - U305 walls OK in both units 238 and 338 / Reviewed accessible elements with contractor | ADAML | ADAML | | BSP | P | 7834974 |
KROESCHELL ROCKY MOUNTAIN, INC | BSP | P | 08/03/2023 | interior osb shear wall fastening OK for units 238 and 338 / reviewed rated assemblies with site rep | LONNYS | LONNYS | | BSP | P | 7816815 |
KROESCHELL ROCKY MOUNTAIN, INC | BFR | P | 07/26/2023 | Unit 238 - This unit has a newly constructed bearing wall and Unit 338 has two newly constructed bearing walls which have to be rated for one hour because this is a 5A building / Also there are (2) 4x6 wood posts that have been added to the bearing wall with a HD3 at the top plate connection and an HD 7 at the bottom plate connection for each post / Update with splice through plan review / Framing OK / Reviewed accessible elements | ADAML | ADAML | | BFR | P | 7808454 |
KROESCHELL ROCKY MOUNTAIN, INC | BFR | P | 07/19/2023 | Interior framing ok Unit 338 -- Pending other rough inspections -- Reviewed Accessible Elements / | CHAD | CHAD | | BFR | P | 7801923 |
ENCORE ELECTRIC, INC. | E= | C | 10/18/2023 | | BRIAN | BRIAN | | E= | C | 7891936 |
ENCORE ELECTRIC, INC. | E= | C | 10/18/2023 | FIRE ALARM INSPECTION: | BRIAN | BRIAN | | E= | C | 7891933 |
ENCORE ELECTRIC, INC. | ER | P | 07/21/2023 | FIRE ALARM INSPECTION: 238. | JOHNN | JOHNN | | ER | P | 7804578 |
ENCORE ELECTRIC, INC. | ER | P | 07/21/2023 | 238. | JOHNN | JOHNN | | ER | P | 7804576 |
ENCORE ELECTRIC, INC. | ER | P | 07/18/2023 | 338, Discussed accessibility requirements with contractor / | JOHNN | JOHNN | | ER | P | 7800618 |
ENCORE ELECTRIC, INC. | ER | P | 07/18/2023 | FIRE ALARM INSPECTION: 338, Discussed accessibility requirements with contractor / | JOHNN | JOHNN | | ER | P | 7800616 |
HEATING & PLUMBING ENGINEERS, INC | H= | C | 12/08/2023 | SPLICE ON FILE. | MARKB | MARKB | | H= | C | 7939572 |
HEATING & PLUMBING ENGINEERS, INC | H= | P | 12/04/2023 | FINAL PENDING - Engineer to address previous mechanical inspection notes. 2ND FLOOR CEILING RADIATION DAMPER IN UNIT 238 COMPLETE. | MARKB | MARKB | | H= | P | 7934726 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 11/22/2023 | 3RD FLOOR: CEILING RADIATION DAMPER SUPPORT COMPLETE FOR 2 DAMPERS. PICTURES OF SECOND FLOOR DAMPER SUPPORT PROVIDED. | MARKB | MARKB | | HD | P | 7926227 |
HEATING & PLUMBING ENGINEERS, INC | HSP | P | 11/09/2023 | --ENGINEER TO ADDRESS: How protection rated floor/ceiling & rated roof/ceiling assemblies.Note on plans says to replace exhaust fan on roof but contractoris not replacing fan-- Currently exhaust grill is in a L525 assembly without protection. | MARKB | MARKB | | HSP | P | 7914073 |
HEATING & PLUMBING ENGINEERS, INC | HD | P | 06/09/2023 | INSTALL DOES NOT MATCH APPROVED PLANS. NEED APPROVED PLAN SPLICE ATTACHED TO PERMIT TO CONFIRM INSTALL AND THE PROTECTION OF BUILDING RATED ASSEMBLIES. | BILLS | BILLS | | HD | P | 7767558 |
HEATING & PLUMBING ENGINEERS, INC | P= | C | 11/14/2023 | Corrections made / reviewed electronically. | DANR | DANR | | P= | C | 7917823 |
HEATING & PLUMBING ENGINEERS, INC | P= | P | 11/09/2023 | Room 338 South toilet needs to flush to open side and need to finish diverter trim on tub / caulk tub spouts / Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / rest okay. | DANR | DANR | | P= | P | 7913696 |
HEATING & PLUMBING ENGINEERS, INC | PTO | C | 08/23/2023 | NOTE/ o.k. | CODYP | CODYP | | PTO | C | 7835122 |
HEATING & PLUMBING ENGINEERS, INC | PTO | P | 07/28/2023 | NOTE/ In wall and over head dwv and water lines o.k./ Still need shower valves, tubs installed and tested, Accessible measurements, and trench drains installed and inspected | CODYP | CODYP | | PTO | P | 7811469 |
ENCORE ELECTRIC, INC. | XES | P | 12/06/2023 | PLAN SPLICE: (No Fee) by: DANIELG for Electrical: As built changes. | DANIELG | DANIELG | | XES | P | 7936628 |
HEATING & PLUMBING ENGINEERS, INC | XMS | T | 12/05/2023 | PAID (REC#2014281): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: Clouds | DALEH | DALEH | | XMS | T | 7936063 |
HEATING & PLUMBING ENGINEERS, INC | XMS | T | 08/29/2023 | PAID (REC#1987162): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: CLOUDS | DALEH | DALEH | | XMS | T | 7840806 |
KROESCHELL ROCKY MOUNTAIN, INC | XBS | T | 08/28/2023 | PAID (REC#1982768) PLAN SPLICE FEE: $50 by: JUSTINL for Construction: Add floor ceiling assemblies / Revise interior floor plans. | JUSTINL | JUSTINL | | XBS | T | 7840128 |
HEATING & PLUMBING ENGINEERS, INC | XPS | T | 08/21/2023 | PAID (REC#1980738) PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Revised sheet P1.1. | SHANEN | SHANEN | | XPS | T | 7832053 |
KROESCHELL ROCKY MOUNTAIN, INC | XBS | T | 08/02/2023 | PAID (REC#1975242) PLAN SPLICE FEE: $50 by: CGIECK for Construction: WALL TYPE CHANGE | CGIECK | CGIECK | | XBS | T | 7815001 |
ENCORE ELECTRIC, INC. | XES | T | 06/29/2023 | PAID (REC#1969605): PLAN SPLICE FEE: $50 by: DANIELG for Electrical: As builts. | DANIELG | DANIELG | | XES | T | 7786487 |