WELLS & WEST GENERAL CONTRACTORS, INC. | B= | C | 01/17/2024 | | BRIANB | BRIANB | | B= | C | 7969470 |
WELLS & WEST GENERAL CONTRACTORS, INC. | B= | P | 10/19/2023 | Building final OK pending other finals /. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | ERIKK | ERIKK | | B= | P | 7893287 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 08/16/2023 | Hard lid framing at entry ok / | ERIKK | ERIKK | | BFR | P | 7828552 |
WELLS & WEST GENERAL CONTRACTORS, INC. | BFR | P | 06/27/2023 | Light gauge metal framing ok / Need to inspect hard lid framing when ready / Reviewed Accessible Elements / | ERIKK | ERIKK | | BFR | P | 7783356 |
NATCO ELECTRIC, INC. | E= | C | 10/16/2023 | Correction made. | AARONR | AARONR | | E= | C | 7889176 |
NATCO ELECTRIC, INC. | E= | P | 09/26/2023 | Need 70 amp transformer breaker on line side panel, 80 amp installed / Need pictures of inside transformer line disconnect and transformer, (cannot shut down due to suite 340 on panel) / Need all Labels on transformer, disconnect and panel / Suite 361 - Ok | BRETC | BRETC | | E= | P | 7868122 |
NATCO ELECTRIC, INC. | ER | C | 09/26/2023 | Ceilings - Ok / 3 VAV's - Ok / | BRETC | BRETC | | ER | C | 7868120 |
NATCO ELECTRIC, INC. | ER | P | 09/18/2023 | Leave tile out around 3 VAV's, need all stranded grounds changed to terminal or run solid to screw, check brkrs and fuses next inspection / Rest of ceilings - Ok | BRETC | BRETC | | ER | P | 7859514 |
NATCO ELECTRIC, INC. | ER | P | 08/18/2023 | Entry hard lid only - Ok | BRETC | BRETC | | ER | P | 7830506 |
SPECIAL SYSTEMS DESIGN,LLC | E= | C | 08/18/2023 | FIRE ALARM INSPECTION: Rough in complete | BRETC | BRETC | | E= | C | 7830503 |
SPECIAL SYSTEMS DESIGN,LLC | ER | C | 08/18/2023 | FIRE ALARM INSPECTION: Rough in complete | BRETC | BRETC | | ER | C | 7830502 |
NATCO ELECTRIC, INC. | ER | R | 08/10/2023 | Entry hall electric only - Ok / Ceiling rough ok, FA not complete ---------do not close ceiling-------------- / | BRETC | BRETC | | ER | R | 7822764 |
NATCO ELECTRIC, INC. | ER | P | 06/22/2023 | walls only marked on plans | CRAIG | CRAIG | | ER | P | 7779882 |
PEAK HEATING & AIR CONDITIONING, INC. | H= | C | 10/04/2023 | RETURN AIR TRANSFER OK / TEST AND BALANCE REPORT RECEIVED. SEE IMAGES /
| LIDO | LIDO | | H= | C | 7876167 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 09/15/2023 | MISSING 20" X 16" TRANSFER AIR THROUGH WALL FOR ROOM 311 / VAV / FPB BOXES AND DUCT ROUGH OK / SUPPLY FLEX DUCT AND REGISTERS OK / RETURN AIR LAY IN GRILLS OK / | LIDO | LIDO | | HD | P | 7858605 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 08/22/2023 | MECHANICAL PLAN PAGE ON FILE IS NOT THE CORRECT PLAN FOR THIS PERMIT. WILL NEED THE CORRECT MECHANICAL PLAN SUBMITTED TO PLAN REVIEW ASAP. NEED CORRECT PLAN ON FILE BEFORE FURTHER INSPECTION CAN BE COMPLETED / | LIDO | LIDO | | HD | P | 7833524 |
PEAK HEATING & AIR CONDITIONING, INC. | HD | P | 06/30/2023 | MECHANICAL PLAN PAGE ON FILE IS NOT THE CORRECT PLAN FOR THIS PERMIT. WILL NEED THE CORRECT MECHANICAL PLAN SUBMITTED TO PLAN REVIEW ASAP. INSPECTED PER PLAN ON SITE: FIRE DAMPER FRAMING FOR SUPPLY AND RETURN AIR TRANSFER TO CORRIDOR OK / | LIDO | LIDO | | HD | P | 7787786 |
DRUMMOND PLUMBING LLC | P= | C | 09/20/2023 | P= ok | FRANKM | FRANKM | | P= | C | 7862502 |
DRUMMOND PLUMBING LLC | P= | R | 09/19/2023 | Not ready | FRANKM | FRANKM | | P= | R | 7861349 |
DRUMMOND PLUMBING LLC | PTO | P | 06/28/2023 | -Insulate overhead H2O -OK on L2 overhead DWV & H2O extension Note : check water heater corrections @ final / check overhead H2O insulation @ final | FRANKM | FRANKM | | PTO | P | 7785166 |
DRUMMOND PLUMBING LLC | PTO | P | 06/26/2023 | -Complete DWV & H2O extension @ L3 ceiling space / Insulate H2O / heat loops required on water heater / drain down required on water heater / solenoid valve w/ leak detector required on water heater per engineer -OK on L3 in wall & overhead DWV & H2O Note : existing VTR | FRANKM | FRANKM | | PTO | P | 7782304 |
PEAK HEATING & AIR CONDITIONING, INC. | XMS | T | 09/14/2023 | PAID (REC#1988511): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Layout revisions | JUSTINC | JUSTINC | | XMS | T | 7857054 |
PEAK HEATING & AIR CONDITIONING, INC. | XMS | T | 09/14/2023 | PAID (REC#1988247): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised layout, scope, schedules, notes | JUSTINC | JUSTINC | | XMS | T | 7856118 |