NEWERA CONSTRUCTION, LLC | B= | C | 10/09/2023 | All other required Final inspections are complete. (This is a computer generated result) | SHAUN | SHAUN | | B= | C | 7881200 |
NEWERA CONSTRUCTION, LLC | B= | P | 09/22/2023 | Building final OK pending other finals /. Additional Inspections Required (computer generated): AIRTECH MECHANICAL, INC. Mechanical Final Inspection is not Completed yet, AMERICAN VETERAN MECHANICAL, LTD. Mechanical Final Inspection is not Completed yet. | SHAUN | SHAUN | | B= | P | 7865113 |
NEWERA CONSTRUCTION, LLC | BFR | C | 06/06/2023 | Reviewed Accessible Elements | SHAUN | SHAUN | | BFR | C | 7764310 |
TRUSTED ELECTRIC | E= | C | 09/01/2023 | interior remodel complete | CHIPO | CHIPO | | E= | C | 7845220 |
TRUSTED ELECTRIC | ER | C | 09/01/2023 | rough in complete | CHIPO | CHIPO | | ER | C | 7845217 |
TRUSTED ELECTRIC | ER | P | 07/31/2023 | Above ceiling OK. | AARONR | AARONR | | ER | P | 7813117 |
TRUSTED ELECTRIC | ER | P | 07/26/2023 | roof top OK | CRAIGS | CRAIGS | | ER | P | 7808449 |
PHILLIPS FIRE DESIGN LLC | E= | C | 07/20/2023 | FIRE ALARM INSPECTION: fire alarm OK | CRAIGS | CRAIGS | | E= | C | 7804075 |
PHILLIPS FIRE DESIGN LLC | ER | C | 07/20/2023 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | ER | C | 7804072 |
PHILLIPS FIRE DESIGN LLC | E= | C | 07/20/2023 | FIRE ALARM INSPECTION: | CRAIGS | CRAIGS | | E= | C | 7804073 |
TRUSTED ELECTRIC | ER | P | 06/06/2023 | Need fire alarm permit pulled and attached, with rough in inspection prior to sheet rock / electrical rough in for walls except bathroom ok | CHIPO | CHIPO | | ER | P | 7764065 |
AMERICAN VETERAN MECHANICAL, LTD. | H= | C | 10/09/2023 | NOTE / PLAN SPLICE COMPLETE / CONTRACTORS SCOPE OF WORK IS COMPLETE / | JERRYF | JERRYF | | H= | C | 7881199 |
AIRTECH MECHANICAL, INC. | H= | C | 10/06/2023 | NOTE / TAB REPORT RECEIVED / SEE IMAGES / | JERRYF | JERRYF | | H= | C | 7879801 |
AIRTECH MECHANICAL, INC. | H= | P | 09/13/2023 | STILL NEED TAB REPORT NOTE / PICTURE OF GREASE GASKET RECEIVED / SEE IMAGES / | JERRYF | JERRYF | | H= | P | 7854505 |
AMERICAN VETERAN MECHANICAL, LTD. | H= | L | 09/08/2023 | REGULATOR LOCATIONS NOT PER PLAN / REST OK / STATUS LOCKED UNTIL INSTALLATION MATCHES PLANS / | MATTM | MATTM | | H= | L | 7851528 |
AMERICAN VETERAN MECHANICAL, LTD. | HI | C | 08/30/2023 | 10 LB TEST OK FOR COOKLINE. REGULATOR LOCATION DOES NOT MATCH APPROVED PLANS / NEED APPROVED VENT LIMITERS FOR MAXITROL REGULATORS / PROVIDE INSTALLATION INSTRUCTIONS FOR PIETRO FIORENTINI REGULATORS. QUESTIONING IF BRASS VENT LIMITOR IS ALLOWED OUTDOORS / HOW IS ANSUL VALVE GOING TO BE PROTECTED? | MATTM | MATTM | | HI | C | 7843008 |
AMERICAN VETERAN MECHANICAL, LTD. | HI | T | 08/28/2023 | PAID (REC#1983345): NOT READY, FEES APPLIED / COOK LINE NOT ON PRESSURE TEST, SEE NOTES FROM 8/15/23 / REGULATOR LOCATIONS NOT PER PLAN. CONTRACTOR TO INSTALL PER PLAN / ALL REGULATORS REQUIRE A SHUT OFF VALVE IMMEDIATELY AHEAD OF REGULATOR PER THE 2015 IFGC SECTION 409.4 / MISSING 2 REGULATORS FOR EXISTING RTU's PER PLANS AND 2015 IFGC SECTION 410.1 / NEED OUTDOOR VENT LIMITERS INSTALLED / HOW WILL ANSUL VALVE BE PROTECTED FROM IMPACT? / REINSPECT ALL / | MATTM | MATTM | | HI | T | 7840212 |
AIRTECH MECHANICAL, INC. | H= | P | 08/15/2023 | NEED TAB REPORT AND INSTALL GASKET AT GREASE FAN (CONTRACTOR TO ATTACH PICTURES OF GASKET TO TAB REPORT NOTE / ALL SA / RA / EXHAUST GRILLES / CONTROLS / INTERLOCKS ARE COMPLETE / | JERRYF | JERRYF | | H= | P | 7827116 |
AMERICAN VETERAN MECHANICAL, LTD. | HSP | P | 08/15/2023 | BEFORE FINAL WILL NEED WILL NEED PRESSURE TEST ON COOK LINE - AND REMOVE BRASS VENT LIMITERS ON ROOF REGULATORS AND REPLACE WITH APPROVED VENTS - WILL NEED TO VERIFY ALL TIE DOWNS - DISCONNECTS AT APPLIANCES UNDER HOOD | JERRYF | JERRYF | | HSP | P | 7827114 |
AIRTECH MECHANICAL, INC. | H= | L | 08/04/2023 | CANCELED AT CALL AHEAD BY SCOTT WITH AIRTECH | JERRYF | JERRYF | | H= | L | 7818110 |
AMERICAN VETERAN MECHANICAL, LTD. | HC | C | 07/24/2023 | OK TO RELEASE ELEVATED PRESSURE METER | JERRYF | JERRYF | | HC | C | 7805473 |
AMERICAN VETERAN MECHANICAL, LTD. | HI | P | 07/24/2023 | STILL NEED COOK LINE INSPECTION - REGULATORS - TIE DOWNS - DISCONNECTS - MEDIUM PRESSURE LABELS - ANSUL VALVE BY FINAL NOTE / PICTURES OF GAS LINE PLUGS RECEIVED / | JERRYF | JERRYF | | HI | P | 7805472 |
AMERICAN VETERAN MECHANICAL, LTD. | HI | P | 07/21/2023 | NEED ALL LINES CAPPED OR CONNECTED BEFORE METER RELEASE - STILL NEED COOK LINE GAS AND PRESSURE TEST - NEED MEDIUM PRESSURE REGULATORS - VENTS - LABELS - TIE DOWNS - DISCONNECTS - ANSUL VALVE WHEN READY NOTE / PRESSURE TEST OK / PIPING PER PLAN / | JERRYF | JERRYF | | HI | P | 7805271 |
AIRTECH MECHANICAL, INC. | HD | P | 07/10/2023 | NEED INSTALLATION MANUAL FOR ALL APPLIANCES UNDER HOOD TO VERIFY CLEARANCES TO COMBUSTIBLE CONSTRUCTION MATERIALS (HOOD WALL WAS COVERED WITHOUT INSPECTION) - NEED REFRIGERATION CONTRACTOR ATTACHED IF CONDENSERS ARE MOUNTED ON ROOF OR HAVE CONDENSATE DRAINS - CONTRACTOR TO HAVE INSTALLATION MANUAL FOR WRAP AND PICTURES OF 1ST LAYER AT TIME OF WRAP INSPECTION NOTE / GREASE DUCT OK WRAP 2 LAYERS OF WRAP | JERRYF | JERRYF | | HD | P | 7793578 |
AIRTECH MECHANICAL, INC. | HD | P | 07/07/2023 | NEED INSTALLATION MANUAL FOR ALL APPLIANCES UNDER HOOD TO VERIFY CLEARANCES TO COMBUSTIBLE CONSTRUCTION MATERIALS (HOOD WALL WAS COVERED WITHOUT INSPECTION) - STILL JOINTS INSPECTED AT TOP OF HOOD AND OFFSET CONNECTION TO CURB DROP NOTE / CURB DROP AND OFFSET LIGHT TESTS INSPECTION OK / | JERRYF | JERRYF | | HD | P | 7791968 |
WHITCOMB PLUMBING AND HEATING LIMITED | P= | C | 09/07/2023 | | CODYP | CODYP | | P= | C | 7849602 |
WHITCOMB PLUMBING AND HEATING LIMITED | P= | P | 09/07/2023 | Vent test received for left water heater, Still need vent test for right water heater, Will need on site inspection for venting | CODYP | CODYP | | P= | P | 7849061 |
WHITCOMB PLUMBING AND HEATING LIMITED | P= | P | 08/30/2023 | Need to pipe water heater vent per pages previously noted, Will need to retest piping, Current test low, NOTE/ Rest o.k. | CODYP | CODYP | | P= | P | 7842382 |
WHITCOMB PLUMBING AND HEATING LIMITED | P= | P | 08/28/2023 | UPDATED 8/29/23 Need to install exhaust per installation instructions with condensate drain on pages 85 and 86, No water at 3 comp sink, Adjust temp at hand sink, Need water heater vent tested, Re inspect water heaters, NOTE/ Rest o.k. | CODYP | CODYP | | P= | P | 7839658 |
WHITCOMB PLUMBING AND HEATING LIMITED | PTO | P | 07/19/2023 | Over head piping: need insulation H2o / need water heater vents installed and tested / MAU make up water? / rest okay. | DANR | DANR | | PTO | P | 7802071 |
WHITCOMB PLUMBING AND HEATING LIMITED | PTO | P | 06/06/2023 | In wall DWV and H2o: Okay | DANR | DANR | | PTO | P | 7763693 |
WHITCOMB PLUMBING AND HEATING LIMITED | PB | P | 05/19/2023 | Need plan revision for new routing and tie in locations of grease and sanitary, NOTE/ Piping and test o.k. for both | CODYP | CODYP | | PB | P | 7749659 |
AIRTECH MECHANICAL, INC. | XMS | T | 09/13/2023 | PAID (REC#1990524): PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised gas | JUSTINC | JUSTINC | | XMS | T | 7854738 |