38NORTH CONSTRUCTION GROUP, LLC | B= | C | 07/28/2023 | All other required Final inspections are complete. (This is a computer generated result) | JASONL | JASONL | | B= | C | 7810971 |
38NORTH CONSTRUCTION GROUP, LLC | B= | P | 07/27/2023 | Final OK pending the completion of outstanding inspections. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), J2D ELECTRIC, INC. Electrical Final Inspection is not Completed yet, HVAC SOLUTIONS, INC. Mechanical Final Inspection is not Completed yet, HARMON - BONDED PLUMBING & HEATING, INC. Plumbing Final Inspection is not Completed yet. | JASONL | JASONL | | B= | P | 7809909 |
38NORTH CONSTRUCTION GROUP, LLC | BFR | P | 06/28/2023 | Observed new interior light gauge partition framing / Reviewed Accessible Elements / pending other rough inspections | JASONL | JASONL | | BFR | P | 7784643 |
J2D ELECTRIC, INC. | E= | C | 07/27/2023 | Electrical ok / | ROB | ROB | | E= | C | 7810650 |
J2D ELECTRIC, INC. | ER | C | 07/27/2023 | Electrical ok / | ROB | ROB | | ER | C | 7810647 |
J2D ELECTRIC, INC. | E= | P | 07/26/2023 | See comments for ER same date as this inspection / Everything else was hot checked & is good | JOSEPH | JOSEPH | | E= | P | 7808653 |
J2D ELECTRIC, INC. | ER | P | 07/26/2023 | Still need to secure electrical raceways with independent ceiling wires. The wire should be securely attached on both ends. / All receptacles w/in 6 feet of new eye wash sink need GFCI protection. / Panel directories not labeled correctly | JOSEPH | JOSEPH | | ER | P | 7808646 |
SPECIAL SYSTEMS DESIGN,LLC | E= | C | 07/26/2023 | FIRE ALARM INSPECTION: | JOSEPH | JOSEPH | | E= | C | 7808601 |
SPECIAL SYSTEMS DESIGN,LLC | ER | C | 07/26/2023 | FIRE ALARM INSPECTION: | JOSEPH | JOSEPH | | ER | C | 7808587 |
SPECIAL SYSTEMS DESIGN,LLC | E= | C | 07/26/2023 | FIRE ALARM INSPECTION: | JOSEPH | JOSEPH | | E= | C | 7808588 |
J2D ELECTRIC, INC. | ER | R | 07/20/2023 | Need to support all MC cable within 12" of box or fitting and not more than 6' between straps / Ceiling cannot be closed until FA is complete / | ROB | ROB | | ER | R | 7804233 |
J2D ELECTRIC, INC. | ER | P | 06/26/2023 | Wall rough ok for electrical--No FA / | ROB | ROB | | ER | P | 7782649 |
J2D ELECTRIC, INC. | ESL | C | 06/19/2023 | 2- floor with 3/4" PVC to wall in Open Office 103 | ROB | ROB | | ESL | C | 7775984 |
HVAC SOLUTIONS, INC. | H= | C | 07/28/2023 | CORRECTIONS MADE SEE IMAGES | NICKE | NICKE | | H= | C | 7810835 |
HVAC SOLUTIONS, INC. | H= | P | 07/26/2023 | REPLACE 3 SECTIONS OF DRYER EXHAUST THAT ARE 30 GAUGE TO MINIMUM OF 28 GAUGE AND LABEL DRYER EXHAUST WITH LENGTH DUE TO BEING OVER 35 FEET. OK TO ATTACH PICTURES TO NEXT INSPECTION RESULT. | NICKE | NICKE | | H= | P | 7808938 |
HVAC SOLUTIONS, INC. | H= | P | 07/26/2023 | TEST AND BALANCE REPORT RECEIVED AND ACCEPTED | NICKE | NICKE | | H= | P | 7808255 |
HARMON - BONDED PLUMBING & HEATING, INC. | P= | C | 07/28/2023 | Correction complete | FRANKM | FRANKM | | P= | C | 7810970 |
HARMON - BONDED PLUMBING & HEATING, INC. | P= | P | 07/25/2023 | Engineer DWV material revision letter recieved , drawing splice in planning | FRANKM | FRANKM | | P= | P | 7807173 |
HARMON - BONDED PLUMBING & HEATING, INC. | P= | P | 07/21/2023 | Complete PB , rest ok | FRANKM | FRANKM | | P= | P | 7804727 |
HARMON - BONDED PLUMBING & HEATING, INC. | PTO | P | 07/07/2023 | insulation at DHW piping ok ( see images ). | TAYLOR | TAYLOR | | PTO | P | 7791607 |
HARMON - BONDED PLUMBING & HEATING, INC. | PTO | P | 06/29/2023 | need to insulate new DHW piping, complete PB inspection, check water heater by final. | TAYLOR | TAYLOR | | PTO | P | 7786586 |
HARMON - BONDED PLUMBING & HEATING, INC. | PB | P | 06/29/2023 | revise plans for service/ break room sinks connecting to 2 inch drain, note: test ok. | TAYLOR | TAYLOR | | PB | P | 7786579 |
HARMON - BONDED PLUMBING & HEATING, INC. | PSP | P | 06/28/2023 | consult. | TAYLOR | TAYLOR | | PSP | P | 7785155 |
HARMON - BONDED PLUMBING & HEATING, INC. | PB | P | 06/22/2023 | need engineers letter for ABS, service/ break room sinks connecting to wet vent for restroom ? revise plans for washer connecting to 3 inch drain. | TAYLOR | TAYLOR | | PB | P | 7779300 |
HARMON - BONDED PLUMBING & HEATING, INC. | XPS | T | 07/26/2023 | PAID (REC#1973000): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Revised sheet P111. | SHANEN | SHANEN | | XPS | T | 7808455 |
SPECIAL SYSTEMS DESIGN,LLC | XES | T | 07/07/2023 | PAID (REC#1971715): PLAN SPLICE FEE: $50 by: RICHG for Electrical: REVISED ELECTRICAL SHEETS. | RICHG | RICHG | | XES | T | 7791849 |
HARMON - BONDED PLUMBING & HEATING, INC. | XPS | T | 06/26/2023 | PAID (REC#1965240): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Revised sheet P111. | SHANEN | SHANEN | | XPS | T | 7781878 |
38NORTH CONSTRUCTION GROUP, LLC | XMS | P | 06/20/2023 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised layout and existing offices | JUSTINC | JUSTINC | | XMS | P | 7776750 |
38NORTH CONSTRUCTION GROUP, LLC | XPS | T | 06/20/2023 | PAID (REC#1963386): PLAN SPLICE FEE: $50 by: SHANEN for Plumbing: Delta 1 revisions: Adjusted sheet P001, PD111 and P111. | SHANEN | SHANEN | | XPS | T | 7776583 |