SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 04/30/2024 | Air Leakage Testing report (Blower Door) Per 2015 IECC Section R402.4.1 on file / | TRENTP | TRENTP | | BSP | P | 8068745 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 04/29/2024 | no blower door attachment | SHAWND | SHAWND | | BSP | P | 8067380 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BIN | C | 01/30/2024 | | JEREMYD | JEREMYD | | BIN | C | 7981008 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 01/30/2024 | ES Report, installation certificate and approved AM&M, for FX Lumberguard on file | JEREMYD | JEREMYD | | BSP | P | 7981005 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 01/30/2024 | Updated blown-in installation certificate on file | JEREMYD | JEREMYD | | BSP | P | 7980987 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BIN | P | 01/18/2024 | Need to provide updated blown in insulation certificate noting exterior soffits / 6 inches in exterior walls, R49 batts in attic, floor insulation okay / Need air leakage test report by final | TRENTP | TRENTP | | BIN | P | 7971646 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFR | C | 01/18/2024 | Items corrected | TRENTP | TRENTP | | BFR | C | 7971641 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BLA | C | 01/18/2024 | | TRENTP | TRENTP | | BLA | C | 7971640 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 01/18/2024 | Engineer letter for frame items on file | TRENTP | TRENTP | | BSP | P | 7970649 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFR | P | 01/11/2024 | Will inspect trusses at re inspection / 1. Missing inverted LUS hangers at multiple outriggers at garage and upper floor roof gable ends / 2. Incomplete fireblocking at main level B vent chase at kitchen / 3. Missing fireblocking at low volt wire at main level primary bedroom closet / 4. Need design professional clarification for notched out LVL headers at basement rec room sliding glass door / Provide Test report and installers certificate for materials used for fire protection of floor per IRC 302.13 EX #4 by final, finished basement, rear deck | TRENTP | TRENTP | | BFR | P | 7965990 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BLA | L | 01/11/2024 | Field cancelled by contractor | TRENTP | TRENTP | | BLA | L | 7965974 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 12/13/2023 | fastening for HUC hangers and wall tie in from previous BSP corrected, photos on file | TRENTP | TRENTP | | BSP | P | 7943475 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | R | 11/09/2023 | Inspection for lower and upper front porch covers, upper and lower rear deck frames, and rear deck cover frame / Need to tie exterior bearing wall at northern end of main level deck to rests of bearing walls / Missing fasteners at both HUC610s for lower deck frame / Both front porch covers and upper rear deck cover okay | TRENTP | TRENTP | | BSP | R | 7914093 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BSP | P | 11/09/2023 | Narrow braced walls at garage okay | TRENTP | TRENTP | | BSP | P | 7914079 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFN | C | 10/25/2023 | Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 7898536 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFI | C | 10/25/2023 | Designer letter for foundation insulation on file / Note: Need to complete BFN | TRENTP | TRENTP | | BFI | C | 7898456 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFD | C | 10/25/2023 | Engineer letter for perimeter drain on file -- Damp proofing noted / Note: Need to complete BFN | TRENTP | TRENTP | | BFD | C | 7898455 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFN | P | 10/25/2023 | Need to provide stamped foundation design, still need to confirm bearing capacity / Engineer letter for foundation on file -- Eufer noted / | TRENTP | TRENTP | | BFN | P | 7898452 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | BFT | C | 10/25/2023 | open hole on file -- 5000 PSF -- usable -- 10% / footing and foundation observation on file - ufer noted / | TRENTP | TRENTP | | BFT | C | 7898447 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 12/29/2023 | Residential Underground: 200-amp 3 Wire New Residence ok to set meter. / | TOMC | TOMC | | ES | C | 7956834 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 12/29/2023 | 1 - 4/0 AL , 2 - # 2 AL , 3 - # 6 AL , 3 - # 10 , irreversible ufer , no mcc , no central vac , inished basement , 2 - sub panels on lower level | TOMC | TOMC | | ER | C | 7956833 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 09/20/2023 | EUG OK ----- 250 ------- | GREGM | GREGM | | EUG | C | 7862162 |
FIREPLACE WAREHOUSE ETC. | HC | C | 01/12/2024 | RELEASE 2 PSIG METER | TREVORH | TREVORH | | HC | C | 7967182 |
FIREPLACE WAREHOUSE ETC. | HV | C | 01/12/2024 | FIRE PLACE VENT THIMBLE AND TERMINATION PER MANUFACTURES INSTRUCTIONS OK / AT FINAL VERIFY CLEARANCES TO UNIT. | TREVORH | TREVORH | | HV | C | 7967180 |
FIREPLACE WAREHOUSE ETC. | HV | P | 01/12/2024 | FIREPLACE MANUAL, SEE IMAGES | JONH | JONH | | HV | P | 7966621 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 01/10/2024 | RELEASE METER UPON COMPLETION OF HV INSPECTION, VERIFY MINI-SPLIT INSTALLATION BY FINAL/ OK TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST / WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN BATHROOM / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE / A/C ROUGH, COIL AND LINESET / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / | TREVORH | TREVORH | | HRR | C | 7964593 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 01/09/2024 | MISSING 5" SUPPLY RUN IN BEDROOM 2(nw basement) FURNACE VENT LACKS NAIL PROTECTION ON MAIN LEVEL OF THE HOME(bottom plate) VERIFY MINI-SPLIT INSTALLATION BY FINAL/ OK TO ATTACH PICTURE OF CORRECTION TO AN INSPECTION REQUEST / WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN BATHROOM / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / FINISHED BASEMENT / DIRECT VENT FURNACE / A/C ROUGH, COIL AND LINESET / OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / | JONH | JONH | | HRR | P | 7963338 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | R | 01/03/2024 | Not ready / Some, not all - B-vent lacks clearance to combustibles in mechanical room soffit, cant see clearance on main level chase; missing or incomplete multiple heat runs; B-vent insulation shield not dovetailed at top; support condensate piping in water heater room / What are the cfms for the range hood? / Re-inspect all / | CASEYM | CASEYM | | HRR | R | 7958977 |
DAVIS GAS SHOP INC | HI | C | 12/01/2023 | Corrections made, see images / Need 2lb approval letter from gas provider by final / | CASEYM | CASEYM | | HI | C | 7932717 |
DAVIS GAS SHOP INC | HI | P | 11/29/2023 | CSST LACKS PROPER SUPPORT IN LOWER NW BEDROOM/ 10 LB TEST OK /(2 LB SYSTEM) 1 FURNACE / 1 WATER HEATER / 1 RANGE / 1 GENERATOR/ 1 STOVE/ BBQ OUTLET/ PROVIDE 2 LB APPROVAL LETTER FROM GAS PURVEYOR BY FINAL/ VERIFY REGULATORS INSTALLED IN MECHANICAL ROOM, GENERATOR, STOVE BY FINAL | JONH | JONH | | HI | P | 7930933 |
HOMEOWNER | PWO | C | 01/12/2024 | HOUSE AND YARD HYDRANT PIPING OK -- CHECK BACK-FLOW INSIDE RESIDENCE AT FINAL | LEE | LEE | | PWO | C | 7967350 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 12/15/2023 | | LEE | LEE | | PTO | C | 7946355 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | P | 12/12/2023 | LOST TEST ON DWV -- NOTES FOR RBD -- FOUR VTR -- AAV @ POWDER LAV, BUTLER AND LAUNDRY SINK -- DRAFT HOOD W/H -- SEAL PIPING THRU EJECTOR LID BY FINAL -- STILL NEED PWO | LEE | LEE | | PTO | P | 7942367 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 09/15/2023 | BSMT ON EJECTOR -- H20 SERVICE THRU WALL AT A LATER DATE PER PLUMBER
| LEE | LEE | | PB | C | 7858210 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | XMS | P | 01/02/2024 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised backgrounds for added bath at upper level | JUSTINC | JUSTINC | | XMS | P | 7957210 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | XBS | T | 11/20/2023 | PAID (REC#2010059): PLAN SPLICE FEE: $50 by: DANM for Construction: Adding a bath to the upper level loft | DANM | DANM | | XBS | T | 7923883 |
SC SCOTT CONSTRUCTION CONSULTING, INC. | XBS | T | 10/24/2023 | PAID (REC#2001790): PLAN SPLICE FEE: $50 by: SHELLEY for Construction: Dropped shower pan framing | SHELLEY | SHELLEY | | XBS | T | 7897597 |