HOMEOWNER | BSP | R | 09/26/2024 | Changed to BSP / All paperwork provided has expired engineering and is for when the main house was built / Paperwork not accepted | TRENTP | TRENTP | | BSP | R | 8223644 |
HOMEOWNER | BFN | R | 09/26/2024 | All paperwork provided has expired engineering and is for when the main house was built / Paperwork not accepted | TRENTP | TRENTP | | BFN | R | 8223629 |
HOMEOWNER | BFR | R | 09/20/2024 | 1. Need to complete foundation inspections / 2. Need design professional clarification for uplift hardware at ridge beams for rafters / 3. Need clarification for added window in primary bedroom not on plans / 4. Door framing to existing house not done at time of inspection / 5. Need to tie interrupted top plates between addition and existing house / 6. Need to dry in rear window and roof penetrations | TRENTP | TRENTP | | BFR | R | 8218049 |
HOMEOWNER | BFN | P | 09/20/2024 | Need to provide soils report noted on open hole provided / Need to provide stamped foundation design with bearing capacity noted / Need to provide footing observation to complete BFT / Open hole on file, no bearing capacity, drain requirements, or grading noted / Foundation observation on file | TRENTP | TRENTP | | BFN | P | 8217758 |
HOMEOWNER | BSP | L | 09/17/2024 | Changed to BSP and cancelled by call ahead / Note: Need to complete all foundation inspections and MEP roughs prior to frame | TRENTP | TRENTP | | BSP | L | 8213186 |
HOMEOWNER | BSP | L | 08/12/2024 | Changed to BSP and cancelled by call ahead / Note: Need to complete all foundation inspections and MEP roughs prior to frame | TRENTP | TRENTP | | BSP | L | 8176144 |
HOMEOWNER | BFN | R | 08/02/2024 | Engineer letter provide is not legible and blurry / Please provide clear copy of letter, soils report, open hole, and stamped foundation design with bearing capacity noted | TRENTP | TRENTP | | BFN | R | 8167439 |
HOMEOWNER | BSP | L | 08/01/2024 | Foundation insulation already approved, slab observation not needed / Need to complete BFT and BFN | TRENTP | TRENTP | | BSP | L | 8165830 |
HOMEOWNER | BFI | C | 07/24/2024 | R10.5 x 30" installed / complete other foundation inspections | GREGT | GREGT | | BFI | C | 8157117 |
HOMEOWNER | BSP | P | 07/23/2024 | Inspection changed to BSP / Dampproofing of foundation walls okay / Note: Need to complete foundation inspections | TRENTP | TRENTP | | BSP | P | 8155868 |
HOMEOWNER | BFI | P | 07/16/2024 | Authorized 3rd party engineer inspection with all observation paperwork to follow / | NATHAN | NATHAN | | BFI | P | 8148399 |
HOMEOWNER | BFN | P | 07/16/2024 | Authorized 3rd party engineer inspection with all observation paperwork to follow / | NATHAN | NATHAN | | BFN | P | 8148398 |
HOMEOWNER | BFT | P | 07/16/2024 | Authorized 3rd party engineer inspection with all observation paperwork to follow / | NATHAN | NATHAN | | BFT | P | 8148395 |
HOMEOWNER | ER | C | 08/29/2024 | electric floor heat ----------- 3 - 40 amp to water heater -------------- contractor will need to do service up grade | CRAIG | CRAIG | | ER | C | 8196103 |
HOMEOWNER | ESL | C | 08/01/2024 | slab ok | BRET | BRET | | ESL | C | 8166993 |
HOMEOWNER | HRR | C | 09/23/2024 | 4" Flex duct installed for 50cfm fan, see images / | CASEYM | CASEYM | | HRR | C | 8219772 |
HOMEOWNER | HRR | P | 09/19/2024 | UPDATE 9-20-24 CM: Changed to partial as bath fan will be used, changing to 4" flex duct / Ok to send pictures with next inspection request /
3" flex duct undersized for 50cfm fan / Bath fan removed at time of inspection, not required with operable window - will need to verify operable window at final (not installed at time of inspection) / NOTE / Electric in floor heat / | CASEYM | CASEYM | | HRR | P | 8216667 |
HOMEOWNER | PTO | C | 09/13/2024 | | LEE | LEE | | PTO | C | 8210532 |
HOMEOWNER | PTO | T | 09/12/2024 | PAID (REC#2106656) FEE FOR FOURTH PTO INSPECTION -- LOW TEST ON H20 -- OTHER OK | LEE | LEE | | PTO | T | 8208997 |
HOMEOWNER | PTO | P | 09/10/2024 | STILL NO TEST ON VENT STACK -- LOW TEST ON H20 ( TEST AT 50 OR 100 PSI ) -- OTHER OK -- NOTES FOR RBD -- NO W/H AT THIS TIME | LEE | LEE | | PTO | P | 8205983 |
HOMEOWNER | PB | C | 08/29/2024 | | DANR | DANR | | PB | C | 8195192 |
HOMEOWNER | PTO | P | 08/29/2024 | Need test DWV and H2o / missing nail protection / install and anchor toilet flange / rest ok. Note: 1 new VTR / AAV lavatory / need tub tempering by final. | DANR | DANR | | PTO | P | 8195159 |
HOMEOWNER | PB | P | 08/02/2024 | AWAITING PHOTO FOR WRAPS -- REST OK | LEE | LEE | | PB | P | 8167854 |
HOMEOWNER | PB | P | 08/02/2024 | ENTRY IS FOR SCH 40 PIPE THRU FOUNDATION WALL ( SEE IMAGES ) | LEE | LEE | | PB | P | 8167441 |
HOMEOWNER | PWO | C | 07/29/2024 | 3/4" WATER FROM EXISTING WELL PIT TO INSIDE FOUNDATION OK | LEE | LEE | | PWO | C | 8161590 |
HOMEOWNER | PB | P | 07/29/2024 | USE OF SDR 35 INSIDE FOUNDATION NOT ALLOWED -- NEED PIPE WRAPS -- REST OK -- DOMESTIC H20 LOOPS OK -- Photo upload requested. If unfamiliar with uploading photos for an inspection, please click the following link: https://youtu.be/QS0hdGSBA6o / | LEE | LEE | | PB | P | 8161577 |