OX CONSTRUCTION LLC | B= | C | 02/25/2025 | Items corrected | TRENTP | TRENTP | | B= | C | 8358825 |
OX CONSTRUCTION LLC | B= | R | 02/21/2025 | Missing minimum 18 inch landing outside of both exterior doors / Missing smoke detector on basement level / Need to complete finals for open mechanical attachments on permit. Additional Inspections Required (computer generated): SPRINGS GAS, INC. Mechanical Final Inspection is not Completed yet, WESTERN FIREPLACE SUPPLY, INC. Mechanical Final Inspection is not Completed yet. | TRENTP | TRENTP | | B= | R | 8356126 |
OX CONSTRUCTION LLC | BEN= | C | 02/21/2025 | | TRENTP | TRENTP | | BEN= | C | 8355927 |
OX CONSTRUCTION LLC | BSP | L | 02/18/2025 | Changed to BSP and cancelled over phone by contractor | TRENTP | TRENTP | | BSP | L | 8352354 |
OX CONSTRUCTION LLC | BEN= | R | 02/18/2025 | Need to complete MEP finals prior to BEN= | TRENTP | TRENTP | | BEN= | R | 8352038 |
OX CONSTRUCTION LLC | BIN | C | 01/02/2025 | Observed R21 in walls & R49 in ceiling. | JOSEPHC | JOSEPHC | | BIN | C | 8314378 |
OX CONSTRUCTION LLC | BFR | C | 01/02/2025 | | JOSEPHC | JOSEPHC | | BFR | C | 8314370 |
OX CONSTRUCTION LLC | BSP | P | 12/31/2024 | Engineer letter on file / | ERIKK | ERIKK | | BSP | P | 8312753 |
OX CONSTRUCTION LLC | BFR | P | 12/23/2024 | Need to frame in door to existing house for inspection / Missing Note A straps per plan / Need to secure shims in crawlspace | TRENTP | TRENTP | | BFR | P | 8308473 |
OX CONSTRUCTION LLC | BFD | C | 11/20/2024 | Engineer letter for perimeter drain on file -- Damp proofing noted / | TRENTP | TRENTP | | BFD | C | 8277449 |
OX CONSTRUCTION LLC | BFN | C | 11/05/2024 | Engineer letter for foundation on file -- Eufer noted / Foundation design on file (Bearing Capacity Verified) / | TRENTP | TRENTP | | BFN | C | 8264026 |
OX CONSTRUCTION LLC | BFT | C | 11/05/2024 | open hole on file -- 4000 PSF -- usable -- 5% / footing and foundation observation on file - ufer noted / foundation design on file (bearing capacity verified) / | TRENTP | TRENTP | | BFT | C | 8264022 |
OX CONSTRUCTION LLC | BSP | P | 11/05/2024 | Soils report on file - 5% | TRENTP | TRENTP | | BSP | P | 8264018 |
OX CONSTRUCTION LLC | BSP | P | 10/25/2024 | Open hole on file, 4000 psf - usable - Need to provide noted soils report / Need to provide rest of foundation paperwork and complete inspections | TRENTP | TRENTP | | BSP | P | 8253987 |
SANCHEZ ELECTRIC, INC. | EP | C | 02/19/2025 | 100 amp 4/w to sub ok | CRAIG | CRAIG | | EP | C | 8353795 |
SANCHEZ ELECTRIC, INC. | E= | C | 02/19/2025 | a/c ok a/c 15 amp hot tub pre wire | CRAIG | CRAIG | | E= | C | 8353794 |
SANCHEZ ELECTRIC, INC. | ER | C | 12/19/2024 | 100 amp sub panel ok | BRET | BRET | | ER | C | 8305428 |
SANCHEZ ELECTRIC, INC. | ER | P | 12/18/2024 | Rough ok feeder not installed to sub panel | BRET | BRET | | ER | P | 8304010 |
WESTERN FIREPLACE SUPPLY, INC. | H= | C | 02/24/2025 | | JONH | JONH | | H= | C | 8358108 |
SPRINGS GAS, INC. | H= | C | 02/24/2025 | | JONH | JONH | | H= | C | 8357977 |
TOM JOHNSON, INC. | H= | C | 02/20/2025 | NOTE/ DIRECT VENT FURNACE/CONDITIONED CRAWL SPACE | JONH | JONH | | H= | C | 8355630 |
TOM JOHNSON, INC. | H= | P | 02/20/2025 | DUCT LEAKAGE, WHOLE HOUSE VENTILATION AND EXHAUST REPORT RECEIVED, SEE IMAGES / ON-SITE SET FOR TODAY TO VERIFY EXHAUST FAN TERMINATION | JONH | JONH | | H= | P | 8354659 |
TOM JOHNSON, INC. | H= | P | 02/13/2025 | provide duct leakage report/ provide images of bath exhaust terminations and flex connections to terminations/ note/ conditioned crawlspace/ direct vent furnace/ | JONH | JONH | | H= | P | 8350222 |
TOM JOHNSON, INC. | HRR | C | 12/23/2024 | | SAMS | SAMS | | HRR | C | 8308564 |
SPRINGS GAS, INC. | HC | C | 12/23/2024 | Adding 160k to existing meter (New connection at meter) | SAMS | SAMS | | HC | C | 8308563 |
SPRINGS GAS, INC. | HI | C | 12/23/2024 | 10lb test ok / Added 70' of 1'' black piping from meter to new addition / 1 furnace / 1 fireplace / 1 BBQ (3/4''@60' good up to 137k)/ | SAMS | SAMS | | HI | C | 8308558 |
TOM JOHNSON, INC. | HRR | P | 12/19/2024 | PARTIAL PENDING GAS INSPECTION// BY FINAL PROVIDE DUCT LEAKAGE REPORT PER IECC R403.3.6 #3. ALL DUCTS AND EQUIPMENT ARE LOCATED WITHIN BUILDING THERMAL ENVELOPE / VERIFY CRAWLSPACE CONDITIONS AT FINAL/NOTE DIRECT VENT FURNACE/CONDITIONED CRAWLSPACE | JONH | JONH | | HRR | P | 8306469 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 12/16/2024 | MAIN LEVEL FIREPLACE CLEARANCE TO COMBUSTIBLES AND VENT TERMINATION OK / NON-COMBUSTIBLE MATERIALS INSTALLED / | JONH | JONH | | HV | C | 8301860 |
MACLINE PLUMBING, LLC | P= | C | 02/20/2025 | Corrections Made | TRAVISR | TRAVISR | | P= | C | 8354730 |
MACLINE PLUMBING, LLC | P= | P | 02/19/2025 | Missing AAV @ KC Drain Need To Properly Cap Off Drain Line @ Laundry Sink Rest OK
To Complete Submit Detailed Photo Of Corrections With Inspection Request | TRAVISR | TRAVISR | | P= | P | 8353694 |
MACLINE PLUMBING, LLC | PTO | C | 01/06/2025 | TWO VTR -- AAV @ C-SPACE FLOOR DRAIN -- TUB TEMPERING IN C-SPACE -- DOMESTIC HOT FROM EXISTING HOUSE -- PIPE INSULATION COMPLETE | LEE | LEE | | PTO | C | 8316809 |