| ADVANTAGE LOG HOMES, INC. | B= | C | 10/27/2025 | All other required Final inspections are complete. (This is a computer generated result) | JOSEPHC | JOSEPHC | | B= | C | 8578122 |
| ADVANTAGE LOG HOMES, INC. | B= | P | 10/23/2025 | Additional Inspections Required (computer generated): External Agency Inspection N= by EPCZONING is not Completed yet (Contact: DPW-DSInspections@elpasoco.com), External Agency Inspection HD= by HEALTHDEPT is not Completed yet. NOTE: unfinished walk-out basement. | JOSEPHC | JOSEPHC | | B= | P | 8576442 |
| ADVANTAGE LOG HOMES, INC. | BEN= | C | 10/23/2025 | | JOSEPHC | JOSEPHC | | BEN= | C | 8576433 |
| ADVANTAGE LOG HOMES, INC. | BEN= | R | 10/23/2025 | BEN not required for permit. | JOSEPHC | JOSEPHC | | BEN= | R | 8575735 |
| ADVANTAGE LOG HOMES, INC. | BFR | C | 10/16/2025 | Garage framing - OK. | JOSEPHC | JOSEPHC | | BFR | C | 8569999 |
| ADVANTAGE LOG HOMES, INC. | BSP | P | 09/05/2025 | Gable end wedge framing corrected.
Garage truss connections at double top plate - OK rest of garage frame to be inspected at future inspection. | JOSEPHC | JOSEPHC | | BSP | P | 8533082 |
| ADVANTAGE LOG HOMES, INC. | BSP | R | 08/27/2025 | Gable end wedge not frame per drawing detail B/RF05.02 and note 4 for outlooker top plate splices / Provide drawing splice for window changes south elevation of garage | GREGT | GREGT | | BSP | R | 8524758 |
| ADVANTAGE LOG HOMES, INC. | BTD | C | 08/27/2025 | State insignia set - #2025-29243 / Serial # 00500PMCOA005299AB | GREGT | GREGT | | BTD | C | 8524740 |
| ADVANTAGE LOG HOMES, INC. | BTD | R | 08/25/2025 | Gable end wedge filler not framed per drawing - insignia not set / secure steel beam shims in beam pocket / Rest of marriage line attachments okay | GREGT | GREGT | | BTD | R | 8521371 |
| ADVANTAGE LOG HOMES, INC. | BSP | R | 08/25/2025 | BVM not required for IRC home | JEREMYD | JEREMYD | | BSP | R | 8521173 |
| ADVANTAGE LOG HOMES, INC. | BSP | P | 08/12/2025 | Sill plate OK per plan/ Center beam, Support columns and pads OK per plan. | JASPREETT | JASPREETT | | BSP | P | 8509969 |
| ADVANTAGE LOG HOMES, INC. | BFT | C | 08/12/2025 | | JASPREETT | JASPREETT | | BFT | C | 8509966 |
| ADVANTAGE LOG HOMES, INC. | BFN | C | 08/12/2025 | Foundation design attached to approved plans/ Bearing capacity verified. | JASPREETT | JASPREETT | | BFN | C | 8509965 |
| ADVANTAGE LOG HOMES, INC. | BFT | P | 07/11/2025 | Open hole on file-- 3500 psf-- Usable 10%. Provide site specific foundation design to verify bearing capacity. | JASPREETT | JASPREETT | | BFT | P | 8481019 |
| HOMEOWNER | E= | C | 10/16/2025 | E= OK ------- | GREGM | GREGM | | E= | C | 8569666 |
| HOMEOWNER | E= | R | 10/15/2025 | NEED GFCI AT 30 AMP OUTLET RIGHT OF GARAGE DOOR --- NEED ENGRAVED PLACARD AT SERVICE DISCONNECT ----- RAISE GRADE LEVEL AT SERVICE DISCONNECT ------ REST OK ---- | GREGM | GREGM | | E= | R | 8568646 |
| MULEY ELECTRIC LLC | ES | C | 09/12/2025 | Residential Underground: 200-amp 3 Wire New Residence . / | GREGM | GREGM | | ES | C | 8539332 |
| MULEY ELECTRIC LLC | ER | C | 09/12/2025 | ER OK ---- GARAGE / BASEMENT BATH ------ | GREGM | GREGM | | ER | C | 8539331 |
| M.P. MECHANICAL AND MAINTENANCE LLC | H= | C | 09/25/2025 | mechanical ventilation report received, see images | JONH | JONH | | H= | C | 8551199 |
| M.P. MECHANICAL AND MAINTENANCE LLC | H= | P | 09/19/2025 | provide mechanical ventilation report for whole house fan in the basement only/ | JONH | JONH | | H= | P | 8547158 |
| M.P. MECHANICAL AND MAINTENANCE LLC | HC | C | 09/15/2025 | RELEASE METER | JONH | JONH | | HC | C | 8540857 |
| M.P. MECHANICAL AND MAINTENANCE LLC | HI | C | 09/15/2025 | 10 LB TEST OK / 3/4 INCH MAIN / 1 FURNACE / -- Field verified a Standard Pressure System. | JONH | JONH | | HI | C | 8540847 |
| M.P. MECHANICAL AND MAINTENANCE LLC | HRR | C | 09/15/2025 | WHOLE HOUSE VENTILATION BEING ACHIEVED THROUGH EXHAUST FAN LOCATED IN BATHROOM / VERIFY WHOLE HOUSE VENTILATION SWITCH LOCATION AT FINAL / NOTE / PARTIAL FINISHED BASEMENT / DIRECT VENT FURNACE/ OUTSIDE AIR WITH DAMPER TO FURNACE RETURN / NO A/C / ELECTRIC WATER HEATER / | JONH | JONH | | HRR | C | 8540842 |
| BIG HORN MECHANICAL | P= | C | 10/23/2025 | See Images For Potable Water Certificate | TRAVISR | TRAVISR | | P= | C | 8575446 |
| BIG HORN MECHANICAL | P= | P | 10/23/2025 | See Images For Potable Water Certificate | TRAVISR | TRAVISR | | P= | P | 8575445 |
| BIG HORN MECHANICAL | PTO | C | 09/19/2025 | Need To Call In Final P= When Permit # P88149 Has Completed & Submitted Potable Water Certificate
Note: Just Need Permit # P88149 To Complete Potable Water Certificate / Rest OK | TRAVISR | TRAVISR | | PTO | C | 8546385 |
| ADVANTAGE LOG HOMES, INC. | PWO | P | 09/12/2025 | Field Cancel Per Request | TRAVISR | TRAVISR | | PWO | P | 8538763 |
| BIG HORN MECHANICAL | PTO | P | 09/11/2025 | Lacking Grade @ 3" DWV @ Master Bathroom Lacking Grade @ 2" Washer Box DWV @ Basement Need To Complete Water Heater Pan Drain Rest OK | TRAVISR | TRAVISR | | PTO | P | 8537645 |
| BIG HORN MECHANICAL | P= | P | 09/11/2025 | Need To Complete PTO Need Potable Water Certificate Uploaded To Permit | TRAVISR | TRAVISR | | P= | P | 8537642 |
| BIG HORN MECHANICAL | PB | C | 08/12/2025 | Note: OK / PWO Is Under Permit # P88149 | TRAVISR | TRAVISR | | PB | C | 8509598 |