Out to Review | Original | / | 1/9/2018 | JANE | JANE | Dillon 719 661 0490 | | Out to Review | 1027292 |
Finished Bin | Original | / | 1/8/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1026865 |
Health Dept. | Original | D | 1/8/2018 | HEALTHDEPT | HEALTHDEPT | Plan review required. Please contact the health department at (719) 578-3199 option 3. RNielsen 575-8965 | rnielsen | Health Dept. | 1026758 |
Health Dept. | Original | / | 1/5/2018 | | SCANNING | Location = Health Dept. by SCANNING | | Health Dept. | 1026324 |
Water Division | Original | D | 1/5/2018 | CSUREVIEW | CSUREVIEW | Need to submit a Backflow Assembly Plan Review Form to determine if a backflow assembly exists. It can be found at https://www.csu.org/CSUDocuments/backflowdomesticform.pdf. Contact Chelsa Shull 719-668-8755 or Holly Link at 719-668-4733 with any questions. RDS | rsolberg | Water Division | 1026245 |
Waste Water Div | Original | D | 1/5/2018 | CSUREVIEW | CSUREVIEW | Contact Bryan Kurth at (719)668-4420 for variance to use a grease trap instead of a grease interceptor. Show its size and add it to the plumbing plans. Add copy of variance letter to this permit set. RDS | rsolberg | Waste Water Div | 1026244 |
Hazmat | Original | D | 1/3/2018 | CSFIRE | CSFIRE | | rpeterson | Hazmat | 1025532 |
CSU Utilities | Original | / | 1/3/2018 | | CSFIRE | Location = CSU Utilities by CSFIRE | rpeterson | CSU Utilities | 1025531 |
CO Springs Fire | Original | D | 1/3/2018 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland Thomas (see full review) | csfdit | CO Springs Fire | 1025529 |
Fire | Original | / | 12/22/2017 | | SCANNING | Location = Fire by SCANNING | | Fire | 1023584 |
Plan Coordinator | Original | / | 12/21/2017 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1023578 |
Plumbing | Original | D | 12/21/2017 | TCRIPPEN | TCRIPPEN | no letter provide for inside grease trap, (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1023577 |
Plumbing | Original | / | 12/21/2017 | | SCANNING | Location = Plumbing by SCANNING | | Plumbing | 1023423 |
Plan Coordinator | Original | / | 12/21/2017 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1023372 |
Mechanical | Original | A | 12/21/2017 | JUSTINC | JUSTINC | | | Mechanical | 1023371 |
Mechanical | Original | / | 12/21/2017 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1023360 |
Mechanical | Original | / | 12/21/2017 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1023342 |
Plan Coordinator | Original | / | 12/21/2017 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1023313 |
Electrical | Original | A | 12/21/2017 | SHELBY | SHELBY | | | Electrical | 1023312 |
Electrical | Original | / | 12/20/2017 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 1023184 |
Electrical | Original | / | 12/20/2017 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1023183 |
Plan Coordinator | Original | / | 12/20/2017 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1023179 |
Construction | Original | D | 12/20/2017 | MICHAELA | MICHAELA | Rated assemblies added do not complete a fire area - see plan No walk-through (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1023178 |
Construction | Original | / | 12/20/2017 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1023169 |
Construction | Original | / | 12/20/2017 | | NELIDA | Location = Construction by NELIDA | | Construction | 1023116 |
Resubmittal 1 | Original | / | 12/20/2017 | NELIDA | NELIDA | Resubmittal #1 12/20/17 | | Resubmittal 1 | 1023113 |
Out to Review | Original | / | 11/20/2017 | NELIDA | NELIDA | Dillon 719-661-0490 | | Out to Review | 1014408 |
Health Dept. | Original | / | 11/16/2017 | | SCANNING | Location = Health Dept. by SCANNING | | Health Dept. | 1013720 |
Out to Review | Original | / | 11/16/2017 | | CSUREVIEW | Location = Out to Review by CSUREVIEW | jnoble | Out to Review | 1013600 |
Water Division | Original | D | 11/16/2017 | CSUREVIEW | CSUREVIEW | Need to provide a Backflow Assembly Plan Review Form. It can be found at https://www.csu.org/CSUDocuments/backflowdomesticform.pdf. An approved reduced pressure backflow device is required, and must be provided if not already existing. Please contact Holly Link at 719-668-4733 or Chelsa Shull at 719-668-8755 to discuss proper backflow requirements. JPN | jnoble | Water Division | 1013599 |
Waste Water Div | Original | D | 11/16/2017 | CSUREVIEW | CSUREVIEW | Contact Kim Caltrider (719-668-4506 or kcaltrider@csu.org) for variance to use a grease trap instead of a grease interceptor. Add copy of variance letter to this permit set. JPN | jnoble | Waste Water Div | 1013596 |
CSU Utilities | Original | / | 11/15/2017 | | CSFIRE | Location = CSU Utilities by CSFIRE | wtaylor | CSU Utilities | 1013440 |
Hazmat | Original | D | 11/15/2017 | CSFIRE | CSFIRE | | wtaylor | Hazmat | 1013439 |
CO Springs Fire | Original | D | 11/15/2017 | CSFIRE | CSFIRE | Submitted By: Taylor II, Wyman L (see full review) | csfdit | CO Springs Fire | 1013437 |
Fire | Original | / | 11/6/2017 | | GSANDERS | Location = Fire by GSANDERS | | Fire | 1010370 |
CO Springs DRE | Original | N | 11/6/2017 | GSANDERS | GSANDERS | All parking requirements met per DP (see full review) | | CO Springs DRE | 1010369 |
Zoning/Planning | Original | / | 11/2/2017 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1009341 |
Plan Coordinator | Original | / | 11/1/2017 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1008991 |
Electrical | Original | D | 11/1/2017 | SHELBY | SHELBY | Show service lateral size, type, and quantity on one line. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1008989 |
Electrical | Original | / | 11/1/2017 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 1008968 |
Electrical | Original | / | 10/27/2017 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1007811 |
Plan Coordinator | Original | / | 10/27/2017 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1007753 |
Mechanical | Original | D | 10/27/2017 | JUSTINC | JUSTINC | Clarify how providing minimum 100 square inch makeup air to clothes dryer? Clarify R/A path from office 104? Verify if CO2 tank will be located within building. If so indicate tank location and size. Verify if within allowable limits per CSFD. If over allowable limits indicate on plan how protecting. Verify 30" service access for water heater location. SF-1 indicates backdraft damper? Clarify how this will work with supply fan? Should this be motorized damper interlocked with CO2 sensor? Kitchen interlock schedule for hoods missing RTU-1 interlock? Vented roof curbs only allowed when duct is to be installed within a 1HR shaft. 3/4" gas as indicated on sheet G1 to cooking equipment. Per 09' IFGC 402.4 (2) 3/4" @ 350' = 53,000 BTU last fryer requires 110,000 BTU gas appears to be short.
MECHANICAL REVIEW INCOMPLETE NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1007751 |
Electrical | Original | / | 10/27/2017 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electrical | 1007647 |
Plumbing | Original | D | 10/25/2017 | TCRIPPEN | TCRIPPEN | need letter from waste water for inside grease trap (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1006933 |
Electrical | Original | / | 10/24/2017 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1006622 |
Plan Coordinator | Original | / | 10/24/2017 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1006556 |
Construction | Original | D | 10/24/2017 | MICHAELA | MICHAELA | Plan is for a Change of Occupancy - M to A-2 A-2 occupancy if non-separated use exceeds 100 occupants and requires sprinklers Does not meet separation of exits requirements No walk-through
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1006555 |
Construction | Original | / | 10/24/2017 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1006495 |
Construction | Original | / | 10/17/2017 | | SCANNING | Location = Construction by SCANNING | | Construction | 1004979 |
Plan Coordinator | Original | / | 10/17/2017 | | BRENT | Location = Plan Coordinator by BRENT | | Plan Coordinator | 1004972 |
Enumeration | Original | A | 10/17/2017 | BRENT | BRENT | | | Enumeration | 1004971 |
Floodplain | Original | N | 10/17/2017 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6435320013) | | Floodplain | 1004883 |