Water Division | Original | A | 4/4/2018 | CSUREVIEW | CSUREVIEW | Comments addressed. RDS | rsolberg | Water Division | 1053992 |
Waste Water Div | Original | A | 4/4/2018 | CSUREVIEW | CSUREVIEW | Comments addressed. RDS | rsolberg | Waste Water Div | 1053991 |
Gas/Elec. Utils | Original | A | 4/4/2018 | CSUREVIEW | CSUREVIEW | Comments addressed. RDS | rsolberg | Gas/Elec. Utils | 1053990 |
Electrical | Original | A | 4/4/2018 | BERTHA | BERTHA | Released for Pavilion Only. | | Electrical | 1053787 |
Mechanical | Original | N | 4/3/2018 | JUSTINC | JUSTINC | NO MECHANICAL SCOPE NO MECHANICAL PERMIT REQUIRED | | Mechanical | 1053566 |
Electronic Plan | Original | / | 4/3/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1053565 |
Construction | Original | A | 3/30/2018 | SHELLEY | SHELLEY | | | Construction | 1052628 |
Enumeration | Original | A | 3/30/2018 | AMY | AMY | 1268 PELOTON-TYPE 2 | | Enumeration | 1052275 |
Resubmittal 2 | Original | / | 3/29/2018 | BECKYA | BECKYA | Resubmittal #2 | | Resubmittal 2 | 1052019 |
Gas/Elec. Utils | Original | D | 1/10/2018 | CSUREVIEW | CSUREVIEW | Show the gas and electric meter locations on the elevation plan views and ensure gas regulator vent is at least 3ft away from any electric meter socket and openings like windows, doors, and garage doors. ERW | ewidrick | Gas/Elec. Utils | 1027618 |
Water Division | Original | D | 1/10/2018 | CSUREVIEW | CSUREVIEW | Requires approved CSU mainline Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8111 with questions. ERW | ewidrick | Water Division | 1027617 |
Waste Water Div | Original | D | 1/10/2018 | CSUREVIEW | CSUREVIEW | Requires approved CSU mainline Construction Plan and approved Utility Service Plan. Contact Utilities Development Services at 668-8111 with questions. ERW | ewidrick | Waste Water Div | 1027614 |
Mechanical | Original | D | 1/10/2018 | TCRIPPEN | TCRIPPEN | Plan reads pavilion type 2 none shown here ? all so missing gas piping and you have two site plans ? (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1027540 |
Electrical | Original | D | 1/10/2018 | SHELBY | SHELBY | Show required disconnect ( 225.31 NEC). (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1027478 |
CO Springs DRE | Original | A | 1/10/2018 | DSEXTON | DSEXTON | Approved. DJS 1/10/2018 (see full review) | | CO Springs DRE | 1027403 |
Zoning/Planning | Original | / | 1/9/2018 | DSEXTON | DSEXTON | In Current Review by DSEXTON | | Zoning/Planning | 1027267 |
Construction | Original | A | 1/9/2018 | DANM | DANM | | | Construction | 1027159 |
Electronic Plan | Original | / | 1/9/2018 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1027146 |
Enumeration | Original | D | 1/5/2018 | AMY | AMY | WHAT PAVILION TYPE IS THIS PLAN FOR? PAGE A-100 SAYS 2, G-203 SAYS 4, G-100 SAYS 2, 1135 TREK TRAIL HTS IS BETWEEN 1119 & 1159 TREK TRAIL HTS. PLEASE CLARIFY PAVILION TYPES IN AN EMAIL WITH PDF TO ME PLEASE. AMY@PPRBD.ORG
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1026139 |
Electronic Plan | Original | / | 1/5/2018 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1026133 |
Resubmittal 1 | Original | / | 1/3/2018 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 1025549 |
Hazmat | Original | N | 11/15/2017 | CSFIRE | CSFIRE | | fdjah74 | Hazmat | 1013146 |
CO Springs Fire | Original | N | 11/15/2017 | CSFIRE | CSFIRE | Submitted By: Hanenberg, Jeffry A | csfdit | CO Springs Fire | 1013145 |
CO Springs DRE | Original | D | 11/8/2017 | DSEXTON | DSEXTON | Disapproved. The Building Permit package does not include a copy of the approved PUD development plan. This pavilion type was not approved under the PUD development plan. Please provide a minor PUD development plan modification to authorize this structure type. DJS 11/8/2017 (see full review) | | CO Springs DRE | 1011193 |
Health Dept. | Original | N | 11/7/2017 | HEALTHDEPT | HEALTHDEPT | Plan review is not needed - Not applicable. JZ 719-575-8966 | Jzimmerman | Health Dept. | 1011095 |
Water Division | Original | D | 11/7/2017 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved CSU mainline Construction Plan, and approved Utility Service Plan. Contact Utilities Development Services at 668-8111 with questions. RDS | rsolberg | Water Division | 1010864 |
Waste Water Div | Original | D | 11/7/2017 | CSUREVIEW | CSUREVIEW | Requires approved Development Plan, approved CSU mainline Construction Plan, and approved Utility Service Plan. Contact Utilities Development Services at 668-8111 with questions. RDS | rsolberg | Waste Water Div | 1010863 |
Gas/Elec. Utils | Original | D | 11/7/2017 | CSUREVIEW | CSUREVIEW | Provide an approved Development Plan, include a proposed location for gas and electric meters on building elevations. RDS | rsolberg | Gas/Elec. Utils | 1010862 |
Electrical | Original | D | 11/7/2017 | BERTHA | BERTHA | 1. Remove all information not reflecting this scope of work. 2. Complete re review is necessary. 3. Eighteen plans in this series 101449, 101450, 101451, 101452, 101453, 101456, 101461, 101463, 101466, 101467, 101475, 101476, 101477, 101481, 101482, 101483, 101484, 101485
Refer to https://www.pprbd.org/plancheck/PLCK%20Com%20Elec%20List%202016.pdf
Call for consultation: Bertha 719-327-2911 or Shelby 719-327-2974
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1010812 |
City Engr | Original | N | 11/6/2017 | PMORRIS | PMORRIS | | | City Engr | 1010396 |
CSU Contract Admin. | Original | N | 11/6/2017 | CSUAPPSPRM | CSUAPPSPRM | | lmpope | CSU Contract Admin. | 1010380 |
Mechanical | Original | D | 11/6/2017 | TCRIPPEN | TCRIPPEN | Plan reads pavilion type 2 none shown here ? (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1010160 |
Plumbing | Original | N | 11/6/2017 | TCRIPPEN | TCRIPPEN | No plumbing work issue no permit. | | Plumbing | 1010159 |
Zoning/Planning | Original | / | 11/6/2017 | DSEXTON | DSEXTON | In Current Review by DSEXTON | | Zoning/Planning | 1010150 |
Construction | Original | D | 11/3/2017 | DANM | DANM | Provide code data on drawings Clarify depth of foundation - not shown on plan as indicated
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1010010 |
Electronic Plan | Original | / | 10/27/2017 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1007727 |
Enumeration | Original | D | 10/26/2017 | AMY | AMY | ON ARCHITECTURAL PAGE A-100 HIGHLIGHT OR PLACE AN ARROW TOWARDS THE AREA OF WORK AND LABEL ADDRESS FOR PAVILION. STRUCTURAL PAGES S-101P-ALL PAVILIONS THAT DO NOT APPLY TO THIS PLAN SHOULD BE CROSSED OUT OR REMOVED. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1007547 |
Floodplain | Original | N | 10/23/2017 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6220001012) | | Floodplain | 1006253 |