Mechanical | Splice 08/06/19 | A | 8/6/2019 | SHANEN | SHANEN | clouded revisions only | | Mechanical | 1220867 |
Out to Review | Splice 08/06/19 | / | 8/6/2019 | BECKYA | BECKYA | | | Out to Review | 1220858 |
Scanned/Finished Bin | Original | / | 2/22/2019 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1161635 |
To Be Scanned Bin | Original | / | 2/21/2019 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1161577 |
Plan Coordinator | Original | / | 2/21/2019 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1161482 |
Mechanical | Original | A | 2/21/2019 | JUSTINC | JUSTINC | Note added for fire/smoke dampers | | Mechanical | 1161480 |
Finished Bin | Original | / | 2/21/2019 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Finished Bin | 1161479 |
Finished Bin | Original | / | 2/14/2019 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1159116 |
Plan Coordinator | Original | / | 2/13/2019 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1159085 |
Mechanical | Original | D | 2/13/2019 | JUSTINC | JUSTINC | Two new fire dampers have been indicated in corridor 56-41 in a smoke barrier. Fire dampers would not be required but is acceptable per the IMC and IBC. However as this is a smoke barrier it must resist the passage of smoke.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1159084 |
Mechanical | Original | / | 2/13/2019 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1158860 |
Mechanical | Original | / | 2/12/2019 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1158469 |
Plan Coordinator | Original | / | 2/12/2019 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1158466 |
Construction | Original | A | 2/12/2019 | MICHAELA | MICHAELA | | | Construction | 1158465 |
Construction | Original | / | 2/12/2019 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1158449 |
Construction | Original | / | 2/12/2019 | | GITA | Location = Construction by GITA | | Construction | 1158406 |
Resubmittal 2 | Original | / | 2/12/2019 | GITA | GITA | Resubmittal #2 | | Resubmittal 2 | 1158405 |
Finished Bin | Original | / | 2/4/2019 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1155699 |
Plan Coordinator | Original | / | 2/4/2019 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1155670 |
Mechanical | Original | D | 2/4/2019 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE AT THIS TIME
Pending construction reviewer comment regarding what type walls. Need to verify what type of walls will be penetrated with dampers to verify the correct type damper is installed with the UL listing to match.
See construction comment
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1155668 |
Mechanical | Original | / | 2/1/2019 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1154946 |
Plan Coordinator | Original | / | 2/1/2019 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1154940 |
Construction | Original | D | 2/1/2019 | MICHAELA | MICHAELA | Please use IBC language for wall identifications All rated assemblies that are required for codes other than the IBC need to be labeled as such RBD will inspect only penetrations of wall required to be rated by the IBC. Any modifications to the structure necessary to allow for new damper installation should be noted on the plan and will be inspected based on the type of wall assembly required by the IBC. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1154936 |
Construction | Original | / | 1/31/2019 | | JANE | Location = Construction by JANE | | Construction | 1154586 |
Resubmittal 1 | Original | / | 1/31/2019 | JANE | JANE | Resubmittal #1 | | Resubmittal 1 | 1154583 |
Finished Bin | Original | / | 1/3/2019 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1146482 |
Water Division | Original | N | 1/3/2019 | CSUREVIEW | CSUREVIEW | No new water service outside of building. RDS | rsolberg | Water Division | 1146405 |
Waste Water Div | Original | N | 1/3/2019 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. RDS | rsolberg | Waste Water Div | 1146404 |
Hazmat | Original | N | 1/3/2019 | CSFIRE | CSFIRE | | rpeterson | Hazmat | 1146388 |
CO Springs Fire | Original | N | 1/3/2019 | CSFIRE | CSFIRE | | rpeterson | CO Springs Fire | 1146387 |
CSU Utilities | Original | / | 1/3/2019 | | CSFIRE | Location = CSU Utilities by CSFIRE | rpeterson | CSU Utilities | 1146386 |
Fire | Original | / | 12/27/2018 | | SDALSING | Location = Fire by SDALSING | | Fire | 1145348 |
CO Springs DRE | Original | N | 12/27/2018 | SDALSING | SDALSING | Interior remodel - no change of use and no exterior work permitted at this time. (see full review) | | CO Springs DRE | 1145347 |
Zoning/Planning | Original | / | 12/20/2018 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1143822 |
Plan Coordinator | Original | / | 12/20/2018 | | SHANEN | Location = Plan Coordinator by SHANEN | | Plan Coordinator | 1143819 |
Plumbing | Original | N | 12/20/2018 | SHANEN | SHANEN | No plumbing work. Issue no permit. | | Plumbing | 1143818 |
Plumbing | Original | / | 12/20/2018 | SHANEN | SHANEN | In Current Review by SHANEN | | Plumbing | 1143783 |
Plumbing | Original | / | 12/19/2018 | | SCANNING | Location = Plumbing by SCANNING | | Plumbing | 1143138 |
Plan Coordinator | Original | / | 12/19/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1143072 |
Mechanical | Original | D | 12/19/2018 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE
Sheet M105-6 Indicates in drawing area key notes 1, and 5. In the commentary there is no key notes 1, or 5?
Key notes 8, 9 indicate options. No options are permitted in permit set. Indicate if dampers will be changed or remove from scope
Verify wall types in key notes 8, and 9. Verify with IBC and architect if these walls are Fire walls as indicated? They appear to be fire barriers? Verify for compliance check
WALK OK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1143071 |
Mechanical | Original | / | 12/19/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1143047 |
Mechanical | Original | / | 12/18/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1142640 |
Plan Coordinator | Original | / | 12/18/2018 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1142578 |
Electrical | Original | A | 12/18/2018 | SHELBY | SHELBY | | | Electrical | 1142577 |
Electrical | Original | / | 12/18/2018 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 1142553 |
Electrical | Original | / | 12/14/2018 | | JANE | Location = Electrical by JANE | | Electrical | 1141706 |
Out to Review | Original | / | 11/27/2018 | NELIDA | NELIDA | Jorge 719-322-4260 | | Out to Review | 1134821 |
Finished Bin | Original | / | 11/19/2018 | | MICHAELA | Location = Finished Bin by MICHAELA | | Finished Bin | 1132083 |
Construction | Original | D | 11/19/2018 | MICHAELA | MICHAELA | NO REVIEW Clarify scope of work - CS form says "addition" of F/S dampers. Why? Rated walls? Missing Key note descriptions
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1132082 |
Construction | Original | / | 11/19/2018 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1132076 |
Construction | Original | / | 11/7/2018 | | GITA | Location = Construction by GITA | | Construction | 1128377 |
Out to Review | Original | / | 11/7/2018 | BRENT | BRENT | | | Out to Review | 1128326 |
Enumeration | Original | N | 11/7/2018 | BRENT | BRENT | | | Enumeration | 1128322 |
Floodplain | Original | N | 11/7/2018 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6408423013) | | Floodplain | 1128298 |