Mechanical | Splice 09/09/20 | A | 9/11/2020 | JUSTINC | JUSTINC | Revised duct sizes, minor layout, schedule, condensate, OSA dampers | | Mechanical | 1381418 |
Electronic Plan | Splice 09/09/20 | / | 9/11/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1381402 |
Electrical | Splice 09/09/20 | A | 9/10/2020 | SHELBY | SHELBY | | | Electrical | 1381052 |
Construction | Splice 09/09/20 | A | 9/10/2020 | MICHAELA | MICHAELA | Revised layout | | Construction | 1380857 |
Electronic Plan | Splice 09/09/20 | / | 9/10/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1380852 |
Plumbing | Splice 08/28/20 | A | 8/28/2020 | SHANEN | SHANEN | Delta 2 revisions: P002 adjusted materials schedule | | Plumbing | 1374904 |
CO Springs Fire | Original | A | 4/2/2020 | CSFIRE | CSFIRE | Reference CSFD review report online for inspection related details.http://springsgov.com/units/fire/Prevent/PlansReview/FPS_WebFPS.asp
please note - there may be up to 24 hour delay in reports being accessible online due to technical difficulties within City of Colorado Springs | dwithee | CO Springs Fire | 1304207 |
Electrical | Original | A | 3/30/2020 | SHELBY | SHELBY | | | Electrical | 1302675 |
Mechanical | Original | A | 3/27/2020 | DALEH | DALEH | | | Mechanical | 1302336 |
Electronic Plan | Original | / | 3/27/2020 | DALEH | DALEH | In Current Review by DALEH | | Electronic Plan | 1302330 |
Enumeration | Original | A | 3/27/2020 | BRENT | BRENT | Tenant occupying Suites 130 and 150. Using Suite 150 as business address. | | Enumeration | 1302304 |
Electronic Plan | Original | / | 3/27/2020 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 1302273 |
Resubmittal 1 | Original | / | 3/27/2020 | GITA | GITA | Resubmittal #1 | | Resubmittal 1 | 1302233 |
Hazmat | Original | N | 3/26/2020 | CSFIRE | CSFIRE | | dwithee | Hazmat | 1301716 |
CO Springs Fire | Original | D | 3/26/2020 | CSFIRE | CSFIRE | Need enumerations approval (see full review) | csfdit | CO Springs Fire | 1301715 |
CO Springs DRE | Original | A | 3/25/2020 | AOSBORNE | AOSBORNE | Medical offices are permitted in PBC zoning. No exterior work, interior only. 34 spaces required for whole site, 43 have been provided. ADA parking will need to be inspected before granting of CO. | | CO Springs DRE | 1301462 |
Electrical | Original | D | 3/23/2020 | SHELBY | SHELBY | Show SCA and SCCR at/for new cooling equipment ( Heat pumps etc). (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1300340 |
Electronic Plan | Original | / | 3/23/2020 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1300326 |
Zoning/Planning | Original | / | 3/20/2020 | AOSBORNE | AOSBORNE | In Current Review by AOSBORNE | | Zoning/Planning | 1299977 |
Plumbing | Original | A | 3/19/2020 | SHANEN | SHANEN | | | Plumbing | 1299455 |
Electronic Plan | Original | / | 3/19/2020 | SHANEN | SHANEN | In Current Review by SHANEN | | Electronic Plan | 1299421 |
City Engr | Original | N | 3/18/2020 | JDAGNILLO | JDAGNILLO | | | City Engr | 1299298 |
Health Dept. | Original | N | 3/18/2020 | HEALTHDEPT | HEALTHDEPT | Not applicable. AB | abrannon | Health Dept. | 1299073 |
CSU Contract Admin. | Original | N | 3/18/2020 | CSUAPPSPRM | CSUAPPSPRM | No fees due for permit. ZS | zshearer | CSU Contract Admin. | 1298964 |
Mechanical | Original | D | 3/17/2020 | JUSTINC | JUSTINC | Provide refrigeration calculation for AC-1 per 2015 IMC 1103.1 on plan. Verify if within allowable limits. If over allowable limits indicate on plan how protecting.
Indicate condensate routing, termination for AC-1 per 2015 IMC 307
Remove ceiling layer from plan for clarity.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1298907 |
Electronic Plan | Original | / | 3/17/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1298887 |
Elevators | Original | N | 3/17/2020 | ERIC | ERIC | No Conveyance | | Elevators | 1298785 |
Water Division | Original | N | 3/17/2020 | CSUREVIEW | CSUREVIEW | AJ | ajuvera | Water Division | 1298681 |
Waste Water Div | Original | N | 3/17/2020 | CSUREVIEW | CSUREVIEW | AJ | ajuvera | Waste Water Div | 1298680 |
Gas/Elec. Utils | Original | N | 3/17/2020 | CSUREVIEW | CSUREVIEW | AJ | ajuvera | Gas/Elec. Utils | 1298679 |
Construction | Original | A | 3/17/2020 | MICHAELA | MICHAELA | | | Construction | 1298660 |
Electronic Plan | Original | / | 3/17/2020 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1298632 |
Enumeration | Original | D | 3/13/2020 | BRENT | BRENT | Plan was submitted under suite 150 but the Enumeration/life safety plan shows 2 separate areas as suite 100. Update suite numbers on plan as needed and highlight area of work. Include a north arrow on the site plan. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1298170 |
Electronic Plan | Original | / | 3/13/2020 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 1298162 |
Floodplain | Original | N | 3/10/2020 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6432202029) | | Floodplain | 1296134 |