Plumbing | Splice 12/14/22 | N | 1/26/2023 | SHANEN | SHANEN | No revised plumbing plans provided with this splice re-submittal. | | Plumbing | 1795478 |
Resubmittal 2 | Splice 12/14/22 | / | 1/26/2023 | ANDREAL | ANDREAL | Resubmittal #2 | | Resubmittal 2 | 1795476 |
Triage | Splice 12/14/22 | N | 1/26/2023 | ANDREAL | ANDREAL | Please read Comment to Reviewer. | | Triage | 1795475 |
Black Forest Fire (CSFD) | Splice 12/14/22 | A | 1/24/2023 | CSFIRE | CSFIRE | | rpeterson | Black Forest Fire (CSFD) | 1794476 |
Mechanical | Splice 12/14/22 | A | 1/23/2023 | JUSTINC | JUSTINC | Layout, backgrounds, sheet notes and schedules revised | | Mechanical | 1794098 |
Electrical | Splice 12/14/22 | A | 1/23/2023 | BERTHA | BERTHA | Revised power, lighting and schedules. | | Electrical | 1793986 |
Electronic Plan | Splice 12/14/22 | / | 1/23/2023 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 1793956 |
Plumbing | Splice 12/14/22 | D | 1/23/2023 | SHANEN | SHANEN | Water entry location and sizing does not match the referenced civil plans. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1793948 |
Construction | Splice 12/14/22 | A | 1/23/2023 | DANM | DANM | Minor floor and reflected ceiling revisions | | Construction | 1793921 |
Electronic Plan | Splice 12/14/22 | / | 1/23/2023 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1793866 |
Resubmittal 1 | Splice 12/14/22 | / | 1/19/2023 | SIERRAC | SIERRAC | Resubmittal #1 | | Resubmittal 1 | 1792804 |
Electrical | Splice 12/14/22 | D | 12/19/2022 | BERTHA | BERTHA | See Mechanical review comments. All backgrounds must match.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Electrical | 1783383 |
Electronic Plan | Splice 12/14/22 | / | 12/19/2022 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 1783312 |
Mechanical | Splice 12/14/22 | D | 12/14/2022 | JUSTINC | JUSTINC | Verify backgrounds. Unable to locate any construction splices that indicate this fire place as relocated to this proposed location. All backgrounds MUST match. This would also revise plumbing and electrical backgrounds.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Mechanical | 1782128 |
Mechanical | Splice 10/24/22 | A | 10/24/2022 | JUSTINC | JUSTINC | Revised gas | | Mechanical | 1760625 |
Construction | Splice 01/31/22 | A | 2/1/2022 | DANM | DANM | Red-W floor trusses changed to engineered trusses; wall listed assembly revised | | Construction | 1630801 |
Electronic Plan | Splice 01/31/22 | / | 2/1/2022 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1630766 |
Resubmittal 1 | Splice 01/31/22 | / | 2/1/2022 | AUSTINK | AUSTINK | Resubmittal #1 | | Resubmittal 1 | 1630691 |
Construction | Splice 01/31/22 | D | 1/31/2022 | DANM | DANM | Original approved permitted structural drawings showed Red-W trusses for the floor framing. This splice submittal seems to indicate those will be replaced with pre-engineered trusses. Provide new engineer stamped and signed floor framing plan showing pre-engineered trusses with alphanumeric labels.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1630019 |
Electronic Plan | Splice 01/31/22 | / | 1/31/2022 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1629981 |
Construction | Splice 01/26/22 | A | 1/26/2022 | DANM | DANM | Deferred log truss engineering | | Construction | 1627505 |
Electronic Plan | Splice 01/26/22 | / | 1/26/2022 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1627481 |
Electrical | Original | A | 5/28/2021 | SHELBY | SHELBY | | | Electrical | 1508459 |
Enumeration | Original | A | 5/26/2021 | AMY | AMY | | | Enumeration | 1506982 |
Electronic Plan | Original | / | 5/26/2021 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1506971 |
Black Forest Fire (CSFD) | Original | A | 5/25/2021 | CSFIRE | CSFIRE | You are responsible for reviewing the APPROVAL comments found on the CSFD website as they contain important inspection information: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – NOTE COMMENTS ARE AVAILABLE FOR 30 DAYS! ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! | dwithee | Black Forest Fire (CSFD) | 1506238 |
Resubmittal 6 | Original | / | 5/25/2021 | ANDREAL | ANDREAL | Resubmittal #6 | | Resubmittal 6 | 1505963 |
Black Forest Fire (CSFD) | Original | D | 5/25/2021 | CSFIRE | CSFIRE | There has been no approval of water supplies by Black Forest Fire for this structure. CSFD cannot release a building for permit until water supplies have been established. | dwithee | Black Forest Fire (CSFD) | 1505773 |
Electrical | Original | D | 5/6/2021 | SHELBY | SHELBY | Include SCCR on short circuit schedule. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1497094 |
Construction | Original | A | 5/3/2021 | DANM | DANM | | | Construction | 1494914 |
Electronic Plan | Original | / | 5/3/2021 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1494897 |
Enumeration | Original | A | 5/3/2021 | AMY | AMY | | | Enumeration | 1494356 |
Electronic Plan | Original | / | 5/3/2021 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1494353 |
Resubmittal 5 | Original | / | 4/29/2021 | ANDREAL | ANDREAL | Resubmittal #5 | | Resubmittal 5 | 1493677 |
Black Forest Fire (CSFD) | Original | D | 4/26/2021 | CSFIRE | CSFIRE | Black Forest Fire is looking into alternative water supply requirements, based upon NFPA 1142, which have not been finalized as of this review. Plans remain disapproved | csfdit | Black Forest Fire (CSFD) | 1490875 |
Electrical | Original | D | 4/13/2021 | SHELBY | SHELBY | 1.Installation violates 225.30 NEC ( One feeder allowed per structure). 2. Show SCCR at/for elevator controller and cooling equipment. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1484944 |
Elevators | Original | A | 4/13/2021 | ERIC | ERIC | Hydraulic LULA elevator. Need final submittals prior to issuing permit | | Elevators | 1484544 |
Construction | Original | D | 4/13/2021 | DANM | DANM | Sheet A6.30 - UL U305 and U314 for the elevator top enclosure were tested for vertical orientation only - provide listing for horizontal assembly
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1484523 |
Electronic Plan | Original | / | 4/13/2021 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1484446 |
Enumeration | Original | A | 4/12/2021 | AMY | AMY | | | Enumeration | 1484063 |
Electronic Plan | Original | / | 4/12/2021 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1484060 |
Resubmittal 4 | Original | / | 4/12/2021 | DANM | DANM | Resubmittal #4 | | Resubmittal 4 | 1483437 |
Black Forest Fire (CSFD) | Original | D | 3/29/2021 | CSFIRE | CSFIRE | YOU WILL NEED TO GET A WRITTEN STATEMENT FROM BLACK FOREST FIRE INDICATING THEIR APPROVAL OF THE FOLLWING: 1- FIRE DEPARTMENT VEHICLE ACCESS TO THE STRUCTURE AND 2- LOCATION AND FLOW OF FIRE HYDRANTS.
THIS BUILDING REQUIRES A MINIMUM OF 1,750 GALLONS PER MINUTES AND A MINIMUM OF 1 HYDRANT. | dwithee | Black Forest Fire (CSFD) | 1477165 |
Plumbing | Original | A | 3/24/2021 | SHANEN | SHANEN | | | Plumbing | 1474825 |
Mechanical | Original | A | 3/23/2021 | JUSTINC | JUSTINC | | | Mechanical | 1473895 |
Electronic Plan | Original | / | 3/22/2021 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1473646 |
Electrical | Original | D | 3/22/2021 | SHELBY | SHELBY | 1. Electrical approval is not possible with out Elevator comments being addressed. 2. Installation violates 225.30, 31, and 32 NEC. ( feeders for panels A and B). 3. MP feeder requires an equipment ground. 4. Show SCA and SCCR at/for elevator controller and cooling equipment. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1473236 |
Electronic Plan | Original | / | 3/19/2021 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1472977 |
County Zoning | Original | A | 3/19/2021 | DSDRANGEL | DSDRANGEL | PPR2023 | | County Zoning | 1472924 |
Construction | Original | D | 3/19/2021 | SHELLEY | SHELLEY | Provide listed horizontal assembly for top of elevator shaft and an enlarged detail of the wall/ceiling intersection. A splice regarding the support for the decorative log members will be required prior to frame inspection. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1472863 |
Elevators | Original | D | 3/19/2021 | ERIC | ERIC | Please provide preliminary elevator submittals Page A0.00 Add ASME A17.1-2013 Code for Elevators to Code Authority Elevator sump pit and sump pump have been removed as they are not required for LULA elevators. . (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1472808 |
Enumeration | Original | A | 3/19/2021 | AMY | AMY | 12730 Black Forest Road | | Enumeration | 1472796 |
Electronic Plan | Original | / | 3/19/2021 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1472784 |
Resubmittal 3 | Original | / | 3/18/2021 | ANDREAL | ANDREAL | Resubmittal #3 | | Resubmittal 3 | 1471943 |
Black Forest Fire (CSFD) | Original | D | 2/24/2021 | CSFIRE | CSFIRE | previous review comments not addressed | csfdit | Black Forest Fire (CSFD) | 1461210 |
CSU Contract Admin. | Original | N | 2/23/2021 | CSUAPPSPRM | CSUAPPSPRM | N/A - Property located outside our service territory, please refer to appropriate service provider. MKL | mkluke | CSU Contract Admin. | 1460940 |
Electrical | Original | D | 2/22/2021 | SHELBY | SHELBY | 1. Please address previous review comments 1 and 2. 2. Comply 210.8 NEC for break room with permanent provisions for cooking ( Circuit A 6-8 etc.). 3. Installation violates 225.30 NEC, 225.31 NEC, and 225.32 NEC. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1460105 |
Electronic Plan | Original | / | 2/22/2021 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1460009 |
County Zoning | Original | D | 2/22/2021 | DSDRANGEL | DSDRANGEL | Site development plan must be approved through EPC Planning prior to approval in PPRBD's system. | | County Zoning | 1459649 |
Plumbing | Original | D | 2/19/2021 | SHANEN | SHANEN | Elevator sump discharge does not comply with section 301.6 Exception: Floor drains, sumps and sump pumps shall be permitted at the base of the shaft, provided that they are indirectly connected to the plumbing system. Discharge elevator sump indirectly to a waste receptor capable of handling a minimum of 50 gpm (100 dfu). Floor drain cannot be located in the elevator equipment room per section 301.6 Prohibited locations. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1459112 |
Mechanical | Original | D | 2/19/2021 | JUSTINC | JUSTINC | Show all CFM and tag. TYPICAL See elevator review comment regarding floor drain Provide refrigeration calculation per 2015 IMC 1103.1 Verify if within allowable limits per table on plan. If over the allowable limits indicate how protecting on plan.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1458988 |
Electronic Plan | Original | / | 2/19/2021 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1458880 |
Elevators | Original | D | 2/19/2021 | ERIC | ERIC | Please provide elevator submittals Add ASME A17.1 Code for Elevators to Code Authority page A0.00 Page M-2.1 and P-2.1 Remove floor drain from elevator machine room as it is not allowed by code Page P-2.1 Elevator sump pump-see previous Plumbing review notes about indirect waste ELEVATOR SUMP PIT AND PUMP NOT REQUIRED FOR LULA ELEVATOR . (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1458868 |
Construction | Original | D | 2/19/2021 | DANM | DANM | Clarify how log columns and trusses are constructed and connected - they present significant life safety issues due to thesize and span of members Sheet A6.30 - vertical continuity of fire barrier at elevator requires assembly to go up to roof sheathing; Elevator shaft appears to be platform framed so all supporting construction must be 1-hr fire-resistance-rated
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1458531 |
Electronic Plan | Original | / | 2/18/2021 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1457732 |
Enumeration | Original | A | 2/17/2021 | AMY | AMY | | | Enumeration | 1457382 |
Resubmittal 2 | Original | / | 2/16/2021 | BECKYA | BECKYA | Resubmittal #2 | | Resubmittal 2 | 1456765 |
Enumeration | Original | D | 2/12/2021 | AMY | AMY | Owner wants a different address 12730 Black Forest Road. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1455641 |
Electronic Plan | Original | / | 2/12/2021 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1455588 |
Resubmittal 1 | Original | / | 2/11/2021 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 1455057 |
Black Forest Hazmat | Original | N | 12/29/2020 | CSFIRE | CSFIRE | | dwithee | Black Forest Hazmat | 1433060 |
Black Forest Fire (CSFD) | Original | D | 12/29/2020 | CSFIRE | CSFIRE | You are responsible for reviewing the disapproval comments found on the CSFD website and responding to them in your resubmittal to RBD: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp | csfdit | Black Forest Fire (CSFD) | 1433057 |
Electrical | Original | D | 12/11/2020 | SHELBY | SHELBY | 1. Electrical approval is not possible without elevator comments being addressed. 2. Show SCA and SCCR at/for elevator controller and new cooling equipment. 3. Show location of all service gear on power plan. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1426020 |
Electronic Plan | Original | / | 12/11/2020 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1425938 |
CSU Contract Admin. | Original | D | 12/8/2020 | CSUAPPSPRM | CSUAPPSPRM | Outside our service territory. Please refer to another provider. ZS | zshearer | CSU Contract Admin. | 1423605 |
Health Dept. | Original | N | 12/7/2020 | HEALTHDEPT | HEALTHDEPT | Not applicable. KM | kmaldonado | Health Dept. | 1423372 |
Mechanical | Original | D | 12/7/2020 | JUSTINC | JUSTINC | See (M) sheets for all mechanical comments associated with this review.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1423154 |
Plumbing | Original | D | 12/7/2020 | SHANEN | SHANEN | High/low drinking fountain required per section 403.1 Minimum number of fixtures. Schedule required high/low drinking fountain. Show location of required high/low drinking fountain on all backgrounds. Show piping for required high/low drinking fountain. If elevator sump is to be installed, schedule and show piping discharging indirectly to an approved waste receptor capable of handling a minimum 50 gpm. ////Note added 2/4/21: AM&M for drinking fountain with bottle filler in images.\\\\ (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1423152 |
Electronic Plan | Original | / | 12/7/2020 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1423130 |
Gas/Elec. Utils | Original | N | 12/7/2020 | CSUREVIEW | CSUREVIEW | Not in Colorado Springs Utilities service territory. DMM | dmakings | Gas/Elec. Utils | 1423092 |
County Waste Water | Original | N | 12/7/2020 | CSUREVIEW | CSUREVIEW | Not in Colorado Springs Utilities wastewater service territory. DMM | dmakings | County Waste Water | 1423091 |
County Water | Original | N | 12/7/2020 | CSUREVIEW | CSUREVIEW | Not in Colorado Springs Utilities water service territory. DMM | dmakings | County Water | 1423090 |
Electronic Plan | Original | / | 12/7/2020 | SHANEN | SHANEN | In Current Review by SHANEN | | Electronic Plan | 1423071 |
Elevators | Original | D | 12/7/2020 | ERIC | ERIC | Basis of design-Hydraulic LULA elevator. Please provide elevator submittals. Page A0.00 Code Authority-add ASME A17.1 2013 Code for Elevators and Escalators. ALL Pages-Label Elevator Machineroom. Page M-2.1 Elevator machineroom requires ventilation. Page E-0.2 Occupancy sensor light control is not allowed, standard light switch required.
SEE below for plan requirements
https://www.pprbd.org/File/Resources/Downloads/CommercialHandout/Elevator%20Conveyance%20final%20V2.pdf . (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1422928 |
County Zoning | Original | D | 12/7/2020 | DSDRANGEL | DSDRANGEL | Site development plan must be approved through EPC Planning prior to approval in PPRBD's system. | | County Zoning | 1422821 |
Zoning/Planning | Original | / | 12/7/2020 | DSDRANGEL | DSDRANGEL | In Current Review by DSDRANGEL | | Zoning/Planning | 1422812 |
Construction | Original | D | 12/7/2020 | DANM | DANM | Elevator enclosure is considered to be a shaft and walls must be 1-hr fire barriers - provide listed assemblies if room adjacent to elevator shaft is elevator machine room then it must be enclosed with 1-hr fire barriers and a horizontal assembly Conference rooms require a more concentrated occupant load factor of 1:15 Sheet A0.40 - include assemblies for fire barriers at elevator shaft and elevator machine room and for horizontal assembly at elevator machine room Provide engineering for log trusses and columns - structural sheets note as "by others" Clarify how reduced vertical clearance is being addressed at exterior and interior stairs per ICC A117.1 307.4 60 minute door rating required at elevator machine room
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1422811 |
Electronic Plan | Original | / | 12/2/2020 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1421201 |
Enumeration | Original | D | 12/2/2020 | AMY | AMY | Each commercial building is required to have a separate address. The new address for this plan is 12738 Black Forest Road. change each and every page of this plan to this address. Title block as well. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1421149 |
Electronic Plan | Original | / | 12/2/2020 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1421126 |
Floodplain | Original | N | 11/30/2020 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5207000004) | | Floodplain | 1420086 |