CO Springs Hazmat | Original | N | 4/13/2022 | CSFIRE | CSFIRE | HazMat N/A - DCT (see full review) | DTillery94 | CO Springs Hazmat | 1664528 |
CO Springs Fire | Original | A | 4/12/2022 | CSFIRE | CSFIRE | Submitted By: Watson, Jacob Thomas
You are responsible for reviewing the APPROVAL comments found on the CSFD website as they contain important inspection information: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – NOTE COMMENTS ARE AVAILABLE FOR 30 DAYS! ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! (see full review) | csfdit | CO Springs Fire | 1663970 |
Plumbing | Original | N | 3/25/2022 | SHANEN | SHANEN | No plumbing scope of work. All required plumbing fixtures are existing to remain. | | Plumbing | 1655520 |
Construction | Original | A | 3/25/2022 | MICHAELA | MICHAELA | | | Construction | 1655500 |
Enumeration | Original | A | 3/25/2022 | BECKYA | BECKYA | This is a single tenant building. Enumerations changed plans to show no suite number. | | Enumeration | 1655469 |
Enumeration | Original | A | 3/24/2022 | BECKYA | BECKYA | | | Enumeration | 1655311 |
Submittal 2 | Original | / | 3/24/2022 | KALLISTAJ | KALLISTAJ | Submittal #2 | | Submittal 2 | 1654777 |
CO Springs Hazmat | Original | D | 3/9/2022 | CSFIRE | CSFIRE | Submitted by: Tillery, Demarcus
HazMat Disapproved per request (see full review) | DTillery94 | CO Springs Hazmat | 1647511 |
CO Springs Fire | Original | D | 3/4/2022 | CSFIRE | CSFIRE | Submitted by James Trimble: You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! (see full review) | csfdit | CO Springs Fire | 1645253 |
Electrical | Original | A | 3/1/2022 | SHELBY | SHELBY | | | Electrical | 1643312 |
Electronic Plan | Original | / | 3/1/2022 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1643306 |
Plumbing | Original | D | 2/17/2022 | SHANEN | SHANEN | B occupancy with an occupant load of 25 requires compliance with 2018 IPC section 403.1 Minimum number of fixtures. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1638540 |
Mechanical | Original | A | 2/15/2022 | JUSTINC | JUSTINC | | | Mechanical | 1637516 |
Electronic Plan | Original | / | 2/15/2022 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1637496 |
Zoning/Planning | Original | / | 2/10/2022 | JMALPICA | JMALPICA | In Current Review by JMALPICA | | Zoning/Planning | 1635584 |
CO Springs DRE | Original | N | 2/10/2022 | JMALPICA | JMALPICA | Interior finish. No changes to exterior. N/A (see full review) | | CO Springs DRE | 1635583 |
CSU Waste Water | Original | N | 2/10/2022 | CSUREVIEW | CSUREVIEW | No apparent conflicts. CM | CoreyM | CSU Waste Water | 1635426 |
CSU Water | Original | N | 2/10/2022 | CSUREVIEW | CSUREVIEW | No apparent conflicts. CM | CoreyM | CSU Water | 1635424 |
Construction | Original | D | 2/10/2022 | MICHAELA | MICHAELA | The shell building originally indicated that the structure would be sprinklered. If there are no sprinklers in this building a 3-hr. Fire Barrier will be required to separate the S-1 occupancy. If there are no sprinklers Suite 100 is already non-compliant as non-separated use. The restrooms in Suite 100 may only be used by the tenants of Suite 120 if they are the same tenant or if a "Common area" is created at the existing toilets that can be accessed by both suites. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1635305 |
Electronic Plan | Original | / | 2/10/2022 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1635135 |
Enumeration | Original | A | 2/7/2022 | BECKYA | BECKYA | Electronic plan was incorrectly submitted as an Interior Remodel. We have added the suite number and changed the plan to Interior Finish. | | Enumeration | 1633195 |
Electronic Plan | Original | / | 2/7/2022 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 1633151 |
Floodplain | Original | N | 2/3/2022 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6436101004) | | Floodplain | 1631648 |