WP Zoning | Original | D | 12/5/2023 | DBURGESS | DBURGESS | Still disapproved pending submittal and approval of Site Plan Review (SPR) application and Construction Drawings. | | WP Zoning | 1935874 |
WP Fire (CSFD Commercial) | Original | A | 11/28/2023 | CSFIRE | CSFIRE | We are pleased to inform you this plan is approved. You are responsible for reviewing the comments through your ACA account. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account.
ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! | dwithee | WP Fire (CSFD Commercial) | 1933197 |
WP Hazmat (CSFD Commercial) | Original | N | 11/28/2023 | CSFIRE | CSFIRE | | dwithee | WP Hazmat (CSFD Commercial) | 1933194 |
Plumbing | Original | A | 11/15/2023 | SHANEN | SHANEN | | | Plumbing | 1928669 |
Construction | Original | A | 11/15/2023 | BPHILLIPS | BPHILLIPS | | | Construction | 1928655 |
Electronic Plan | Original | / | 11/15/2023 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 1928617 |
Submittal 3 | Original | / | 11/15/2023 | QUINTONW | QUINTONW | Submittal #3 | | Submittal 3 | 1928570 |
WP Hazmat (CSFD Commercial) | Original | D | 4/6/2023 | CSFIRE | CSFIRE | multiple previous comments not addressed. see fire comments | jt09ff | WP Hazmat (CSFD Commercial) | 1826496 |
WP Fire (CSFD Commercial) | Original | D | 4/6/2023 | CSFIRE | CSFIRE | Submitted by James Trimble: You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! (see full review) | csfdit | WP Fire (CSFD Commercial) | 1826493 |
Plumbing | Original | D | 3/28/2023 | SHANEN | SHANEN | Provide correct address on all sheets, see WP Enumeration comments. Show water service extending a minimum of 30 inches beyond the exterior walls of the building. Water service entry location and sizing must correspond with the utility service plans. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1821473 |
Construction | Original | D | 3/28/2023 | BPHILLIPS | BPHILLIPS | Design live (snow) loads must match. Trusses show 40 psf, plan shows 45. Still need reference to provided soils report. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Construction | 1821397 |
Electronic Plan | Original | / | 3/28/2023 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 1821353 |
WP Waste Water | Original | D | 3/27/2023 | DBURGESS | DBURGESS | Disapproved pending submittal and approval of Site Plan Review (SPR) application and Construction Drawings. | | WP Waste Water | 1821088 |
WP Water | Original | D | 3/27/2023 | DBURGESS | DBURGESS | Disapproved pending submittal and approval of Site Plan Review (SPR) application and Construction Drawings. | | WP Water | 1821087 |
WP Zoning | Original | D | 3/27/2023 | DBURGESS | DBURGESS | Disapproved pending submittal and approval of Site Plan Review (SPR) application and Construction Drawings. | | WP Zoning | 1821085 |
WP Enumeration | Original | A | 3/27/2023 | DBURGESS | DBURGESS | Updated the address on the plan review record & Plan Label. Verified the owner. Added Address Point to the PPRBD GIS Mapping. Added the Teller County Tax Account number to the Code Study Form & verified the Legal Description. | | WP Enumeration | 1821011 |
Submittal 2 | Original | / | 3/24/2023 | KALLISTAJ | KALLISTAJ | Submittal #2 | | Submittal 2 | 1820598 |
WP Waste Water | Original | D | 10/24/2022 | DBURGESS | DBURGESS | Pending WP Utilities Dept. review - disapproved at this time to release e-plan set to address PPRBD reviewer's comments. | | WP Waste Water | 1760648 |
WP Water | Original | D | 10/24/2022 | DBURGESS | DBURGESS | Pending WP Utilities Dept. review - disapproved at this time to release e-plan set to address PPRBD reviewer's comments. | | WP Water | 1760647 |
WP Hazmat (CSFD Commercial) | Original | D | 7/29/2022 | CSFIRE | CSFIRE | | jt09ff | WP Hazmat (CSFD Commercial) | 1720912 |
WP Fire (CSFD Commercial) | Original | D | 7/29/2022 | CSFIRE | CSFIRE | Submitted by James Trimble: You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! (see full review) | csfdit | WP Fire (CSFD Commercial) | 1720910 |
Mechanical | Original | A | 7/21/2022 | JUSTINC | JUSTINC | | | Mechanical | 1716835 |
Plumbing | Original | D | 7/21/2022 | SHANEN | SHANEN | Show water service entrance location that corresponds with the utilities plan. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1716756 |
WP Zoning | Original | D | 7/18/2022 | DBURGESS | DBURGESS | Pending submittal of all required documentation to the City of WP per Ordinance No. 1423, Series 2022 as approved by City Council on June 16, 2022. All plans as required by the ordinance shall be in final form - no "preliminary" or "not for construction" notations. See required ZDP applications for submittal requirements. | | WP Zoning | 1715197 |
Electrical | Original | A | 7/18/2022 | DANIELG | DANIELG | Approved for vehicle storage only. | | Electrical | 1714605 |
Electronic Plan | Original | / | 7/18/2022 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 1714604 |
Construction | Original | D | 7/15/2022 | BPHILLIPS | BPHILLIPS | Show maximum travel distance on life safety plan. Provide IECC/ Comcheck for insulation envelope compliance. Revise occupancy information per reviewer's notes. Indicate locations of exit signs on RCP. Per ANSI, show max measurement to top of sink @ 34". Reference soils report on structural sheet F-1. Design dead loads for roof framing must match. Trusses show 20 psf, plan shows 15. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1714542 |
Electronic Plan | Original | / | 7/14/2022 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 1713759 |
WP Floodplain | Original | N | 7/14/2022 | DBURGESS | DBURGESS | Verified not in a floodplain | | WP Floodplain | 1713631 |
WP Enumeration | Original | D | 7/14/2022 | DBURGESS | DBURGESS | A Change of Address letter was sent on June 10, 2022 changing the address from "2730 Mountain Glen Court" to "20499 E. US 24" and the Teller County Assessor's Office data reflects this change, as well as the e911 system. Project submittal needs to reflect this address change, including all drawings for this project. Address Change letter has been uploaded to "Images" of this plan review record. | | WP Enumeration | 1713627 |