Electrical | Original | A | 12/27/2022 | BERTHA | BERTHA | | | Electrical | 1785468 |
Electronic Plan | Original | / | 12/27/2022 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 1785466 |
Plumbing | Original | A | 12/27/2022 | SHANEN | SHANEN | | | Plumbing | 1785180 |
Electronic Plan | Original | / | 12/27/2022 | SHANEN | SHANEN | In Current Review by SHANEN | | Electronic Plan | 1785145 |
Construction | Original | A | 12/27/2022 | MICHAELA | MICHAELA | | | Construction | 1785063 |
Submittal 3 | Original | / | 12/27/2022 | KALLISTAJ | KALLISTAJ | Submittal #3 | | Submittal 3 | 1784911 |
Health Dept. | Original | A | 12/12/2022 | HEALTHDEPT | HEALTHDEPT | Retail food establishment remodel approved in plan review. A pre-operational inspection will be required before final approval for opening is granted. AF | Amanda Furno | Health Dept. | 1781066 |
Health Dept. | Original | / | 12/12/2022 | HEALTHDEPT | HEALTHDEPT | | Amanda Furno | Health Dept. | 1781065 |
Electrical | Original | A | 10/20/2022 | SHELBY | SHELBY | | | Electrical | 1759790 |
Electronic Plan | Original | / | 10/20/2022 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1759789 |
Health Dept. | Original | D | 10/20/2022 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review is in process and not yet approved. For questions, contact Environmental Health at 719-578-3199 option 3. AF | Amanda Furno | Health Dept. | 1759141 |
CSU Waste Water | Original | A | 10/19/2022 | CSUREVIEW | CSUREVIEW | AJ | ajuvera | CSU Waste Water | 1758617 |
Plumbing | Original | A | 10/19/2022 | SHANEN | SHANEN | | | Plumbing | 1758498 |
Submittal 2 | Original | / | 10/19/2022 | KALLISTAJ | KALLISTAJ | Submittal #2 | | Submittal 2 | 1758475 |
CO Springs Hazmat | Original | N | 9/14/2022 | CSFIRE | CSFIRE | | dwithee | CO Springs Hazmat | 1741211 |
CO Springs Fire | Original | N | 9/14/2022 | CSFIRE | CSFIRE | NO FIRE FINAL (see full review) | csfdit | CO Springs Fire | 1741210 |
Health Dept. | Original | D | 8/24/2022 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/service/retail-food-establishment-licensing-0. Please email application and all required documents to healthinfo@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. MT | mtemple | Health Dept. | 1733133 |
Mechanical | Original | N | 8/24/2022 | JUSTINC | JUSTINC | | | Mechanical | 1732834 |
Electrical | Original | D | 8/22/2022 | BERTHA | BERTHA | Provide one-line to include conduit/conductor size, type, and quantity, beginning at the utility transformer, to include all conductors in the chain of supply for the electrical equipment in the scope of work
Provide service load summary.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1731943 |
CSU Waste Water | Original | D | 8/22/2022 | CSUREVIEW | CSUREVIEW | Contact CSU Industrial Pretreatment representative Bob Bowren via email at fog@csu.org to determine if a variance for an interior grease trap is applicable. If applicable, provide a copy of the Variance letter in the building plan set. CM | CoreyM | CSU Waste Water | 1731927 |
CSU Water | Original | N | 8/22/2022 | CSUREVIEW | CSUREVIEW | No apparent conflicts. CM | CoreyM | CSU Water | 1731926 |
CO Springs DRE | Original | N | 8/22/2022 | CHUDSPETH | CHUDSPETH | Interior commercial remodel, no change of use or occupancy. Remove produce cooler, and add sushi prep station. (see full review) | | CO Springs DRE | 1731858 |
Zoning/Planning | Original | / | 8/22/2022 | CHUDSPETH | CHUDSPETH | In Current Review by CCORCORAN | | Zoning/Planning | 1731855 |
Electronic Plan | Original | / | 8/22/2022 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 1731842 |
Plumbing | Original | D | 8/22/2022 | SHANEN | SHANEN | Provide required CSU variance letter for the indoor grease interceptor. Contact Robert Bowren at 719-668-1735 or fog@csu.org Hand sink must discharge through the grease interceptor. 3-comparment sink shall discharge through an indirect waste pipe per section 802.1.1. Provide an indirect waste receptor for the 3-compartment sink. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1731693 |
Construction | Original | N | 8/22/2022 | MICHAELA | MICHAELA | | | Construction | 1731617 |
Electronic Plan | Original | / | 8/22/2022 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1731600 |
Enumeration | Original | N | 8/19/2022 | BECKYA | BECKYA | | | Enumeration | 1730487 |
Floodplain | Original | N | 8/18/2022 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6309015022) | | Floodplain | 1729805 |