Triage | Original | D | 6/9/2023 | KALLISTAJ | KALLISTAJ | Strictly for extension of Plan/ePlan for 12 MOS. | | Triage | 1854290 |
Plumbing | Original | D | 11/14/2022 | SHANEN | SHANEN | Construction review comments must be addressed. CSU comments must be addressed. P-001-8: Remove all fixtures from the fixture schedule that do not apply to building 8. P-111-8: 1"domestic and 4" fire service per sheet C8.2 (1-1/2" and 3" shown). Building drain to sewer junction location/sizing can not be verified with referenced civil drawings. P-401-8: For clarity, show the DWV and water distribution piping for each unit plan on the applicable unit plan and not for the unit plan above. P-500-8: CWB-1 connected to wet vented bathroom group does not comply with section 912.1 Horizontal wet vent permitted. Only the fixtures within the bathroom groups shall connect to the wet-vented horizontal branch drain. Provide an isometric drawing for the water distribution system. Provide a typical pex manifold water distribution system showing manifold shut off valves, manifold sizing and piping to each fixture. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1770153 |
CO Springs Fire | Original | D | 11/7/2022 | CSFIRE | CSFIRE | WALK OK – See our “Virtual” Walk Through process here: https://coloradosprings.gov/sites/default/files/inline-images/walk-thru_memo.pdf
You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! | rpeterson | CO Springs Fire | 1767371 |
CO Springs Hazmat | Original | N | 11/7/2022 | CSFIRE | CSFIRE | | rpeterson | CO Springs Hazmat | 1767370 |
Electrical | Original | D | 11/1/2022 | BERTHA | BERTHA | 1. Pending approval in Enumeration - Multi meter services must include a list of secondary enumerated addresses on the one-line. Addresses must be approved by Enumeration 2. Pending approval in Construction - Accessibility plan is required. The accessibility does not need to be part of the electrical drawing set. 3. Provide verification that unit panels are not in rated assemblies. 4. Provide volt amps for all branch circuit, feeder and service loads. Indicate calculated load on panels and meter stacks in amps. 5. Provide all conductor size, type and quantity on the one-line. 6. Comply with 250.66 - NEC.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Electrical | 1764533 |
Electronic Plan | Original | / | 10/31/2022 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 1763644 |
Mechanical | Original | D | 10/31/2022 | DALEH | DALEH | See plan track number 168161 for similar comments PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Mechanical | 1763608 |
Electronic Plan | Original | / | 10/31/2022 | DALEH | DALEH | In Current Review by DALEH | | Electronic Plan | 1763451 |
City Engr | Original | D | 10/28/2022 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan and a copy of both the Stormwater Enterprise approved Grading & Erosion Control Plan and Permanent Control Measure (Permanent Water Quality Facility) Plan in the electronic building permit set. (Project Dox #STM-REV22-0852) | | City Engr | 1763128 |
CSU Water | Original | D | 10/27/2022 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Ensure the service line and meter sizes match what is proposed on the utility service plan and commercial water meter sizing form. 3" fire service lines are not allowed (correct the 3" FL on plumbing plans) Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | CSU Water | 1762571 |
CSU Waste Water | Original | D | 10/27/2022 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | CSU Waste Water | 1762570 |
Gas/Elec. Utils | Original | D | 10/27/2022 | CSUREVIEW | CSUREVIEW | Approved Development Plan must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | Gas/Elec. Utils | 1762567 |
Health Dept. | Original | D | 10/27/2022 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at: https://www.elpasocountyhealth.org/service/air-quality/construction-activity-application. Please email application and all required documents to healthinfo@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3.CM | cmille96 | Health Dept. | 1762517 |
CSU Contract Admin. | Original | D | 10/27/2022 | CSUAPPSPRM | CSUAPPSPRM | Commercial Water Meter Sizing Form (CWMSF) approved 10/18/2022. Requires payment of applicable utility charges/fees. Please contact our office at 719-668-8111 for additional information on charges/fees and to request an estimate.
AMS | ASweet | CSU Contract Admin. | 1762474 |
CO Springs DRE | Original | D | 10/27/2022 | APAQUETTE | APAQUETTE | Please provide APPROVED development plan entitlement. No approval stamp from City Planning is located on submitted DP. (see full review) | | CO Springs DRE | 1762392 |
Construction | Original | D | 10/27/2022 | SHELLEY | SHELLEY | Several items on Code Study Form not completed. Provide compliant accessibility plan - no accessibility review Please also include accessible parking figures and locations of accessible stalls. Clarify if storage rooms will be on the garage side or the unit side of the occupancy separation. Label all rated assemblies on sections. Label all wall types on enlarged plans. Revise door rating at occupancy separation. Remove or cross off all wall types that are not applicable to this structure. Put sheets in order per the index. Remove all language regarding townhouses, as those are done out of the IRC. U occupancies can only be 2 stories with full NFPA 13 sprinklers. Building is 3 stories and requires the U occupancy to be separated from the R-2 in order to meet the story limitations of the IBC. Show where the separation occurs and specify correct wall type (fire barriers/horizontal assemblies), correct opening protections, and correct supporting construction as necessary. Provide sum of the ratios as applicable for stories that contain both R2 and U occupancies. Clarify where occupancy separation occurs between U and R in order to meet the 2 story height limitation of the U on LSP. LSP is incomplete, see plan for all requirements. Water entry must be separated from unit Remove or cross off all structural details that are not a part of this structure.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Construction | 1762359 |
Enumeration | Original | D | 10/25/2022 | BRENT | BRENT | See comments from 10/13/22 PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Enumeration | 1761305 |
Plan Coordinator | Original | D | 10/18/2022 | SHELLEY | SHELLEY | Disapprove all remaining departments to allow plan to be resubmitted - see construction review | | Plan Coordinator | 1757749 |
Construction | Original | D | 10/18/2022 | SHELLEY | SHELLEY | REVIEW STOPPED - Clarify building. Portions of plans indicate this is being looked at as a townhome (IRC), and other portions indicate IBC R-2. As an R-2, the U (garage) is the driving occupancy for height and area, and must be separated at the first floor level because of height restrictions. As an IRC townhome, those restrictions do not apply. Put plan in order per the index. Provide compliant accessibility plan. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Construction | 1757748 |
Elevators | Original | N | 10/14/2022 | ERIC | ERIC | No conveyance | | Elevators | 1756485 |
Electronic Plan | Original | / | 10/14/2022 | CHRISTAW | CHRISTAW | In Current Review by CHRISTAW | | Electronic Plan | 1756477 |
Enumeration | Original | D | 10/13/2022 | BRENT | BRENT | Include a site plan showing the parcel and all proposed buildings with addressing and the area of work highlighted in the architectural plan pages. The secondary addressing shown is incorrect. The first digit should not be the building number. The secondary addressing should be 101,102, etc. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Enumeration | 1756370 |
Floodplain | Original | N | 10/13/2022 | BRENT | BRENT | | | Floodplain | 1756369 |
Electronic Plan | Original | / | 10/13/2022 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 1756365 |