Plumbing | Splice 05/16/23 | A | 5/18/2023 | SHANEN | SHANEN | Delta 4 revisions: Adjusted sheet P-101 and P-701. | | Plumbing | 1844906 |
Mechanical | Splice 05/16/23 | A | 5/16/2023 | JUSTINC | JUSTINC | Revised gas | | Mechanical | 1843859 |
Falcon Fire (CSFD) | Splice 04/25/23 | A | 4/26/2023 | CSFIRE | CSFIRE | removed 2nd doors in 106 and 107 and removed fireplace | Jacob.Watson | Falcon Fire (CSFD) | 1835715 |
Construction | Splice 04/25/23 | A | 4/25/2023 | JUSTINL | JUSTINL | Remove 2nd door at 106 -107 / Remove fireplace at waiting. | | Construction | 1834977 |
Electronic Plan | Splice 04/25/23 | / | 4/25/2023 | JUSTINL | JUSTINL | In Current Review by JUSTINL | | Electronic Plan | 1834965 |
Woodmen Hills Waste Water | Original | A | 2/28/2023 | WOODMENHLSMETRO | WOODMENHLSMETRO | WHMD has no objection to the proposed improvements. | rmanginoWHMD | Woodmen Hills Waste Water | 1808321 |
Falcon Highlands Water | Original | A | 2/28/2023 | FALCONHIGHMETRO | FALCONHIGHMETRO | Plumbing piping must be per the following: - Storm must be separate from waste (i.e., roof drainage separate from sewer. Interior floor drains are considered sewer). - All sewer and vent piping must be Schedule 40 PVC inside the building and the foundation. Buried sewer must be SDR35 PVC from the building footprint to the sewer tap. All buried water service line shall be polyethylene (high-density polyethylene – HDPE) - All interior water lines shall be cross-linked polyethylene (PEX). Copper is not allowed in or outside of the building. | rmangino | Falcon Highlands Water | 1807935 |
Waste Water Div | Original | / | 2/3/2023 | SYSTEM | SYSTEM | Contact Waste Water Div department for approval prior to permit | | Waste Water Div | 1798717 |
Water Division | Original | / | 2/3/2023 | SYSTEM | SYSTEM | Contact Water Division department for approval prior to permit | | Water Division | 1798716 |
Falcon Fire (CSFD) | Original | A | 2/3/2023 | CSFIRE | CSFIRE | You are responsible for reviewing the APPROVAL comments found on the CSFD website as they contain important inspection information: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – NOTE COMMENTS ARE AVAILABLE FOR 30 DAYS! ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! (see full review) | csfdit | Falcon Fire (CSFD) | 1798523 |
Mechanical | Original | A | 1/20/2023 | JUSTINC | JUSTINC | | | Mechanical | 1793317 |
Submittal 3 | Original | / | 1/19/2023 | BECKYA | BECKYA | Submittal #3 | | Submittal 3 | 1793180 |
Falcon Fire (CSFD) | Original | D | 12/29/2022 | CSFIRE | CSFIRE | WALK OK – See our “Virtual” Walk Through process here: https://coloradosprings.gov/sites/default/files/inline-images/walk-thru_memo.pdf
You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! | rpeterson | Falcon Fire (CSFD) | 1786096 |
Electrical | Original | A | 12/27/2022 | BERTHA | BERTHA | | | Electrical | 1785353 |
Electronic Plan | Original | / | 12/27/2022 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 1785349 |
Plumbing | Original | A | 12/27/2022 | SHANEN | SHANEN | | | Plumbing | 1785255 |
Plumbing | Original | D | 12/22/2022 | SHANEN | SHANEN | Drinking fountain with bottle filler alternate materials and methods application form fee must be paid prior to processing. ////Updated 12/27/22: Fee paid on 12/02/22.\\\\ PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1784595 |
Mechanical | Original | A | 12/21/2022 | JUSTINC | JUSTINC | | | Mechanical | 1784471 |
Construction | Original | A | 12/21/2022 | MICHAELA | MICHAELA | | | Construction | 1784460 |
Enumeration | Original | A | 12/21/2022 | BECKYA | BECKYA | | | Enumeration | 1784355 |
Electronic Plan | Original | / | 12/21/2022 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 1784220 |
Submittal 2 | Original | / | 12/21/2022 | KALLISTAJ | KALLISTAJ | Submittal #2 | | Submittal 2 | 1784205 |
Falcon Fire (CSFD) | Original | D | 11/28/2022 | CSFIRE | CSFIRE | Submitted By: Valdez, Philip Warren
You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! (see full review) | csfdit | Falcon Fire (CSFD) | 1775612 |
Plumbing | Original | D | 11/23/2022 | SHANEN | SHANEN | Drinking fountain alternate materials and methods application form fee must be paid prior to processing. All gas piping related items must be on the mechanical plans. Remove all references to gas piping from the plumbing plans. Provide required water pipe size analysis data, see 2018 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. P-501 water heater detail: Expansion tank located upstream of the vacuum breaker does not comply with section 607.3 Thermal expansion control. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1774886 |
Electrical | Original | D | 11/18/2022 | RICHG | RICHG | Provide floor plan indicating location of all electrical equipment -Disconnect location
Comply with 250.122 (G) NEC
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Electrical | 1773168 |
Mechanical | Original | D | 11/15/2022 | JUSTINC | JUSTINC | See (M) sheets for comments PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Mechanical | 1771164 |
Construction | Original | D | 11/15/2022 | MICHAELA | MICHAELA | There cannot be a sliding door in the means of egress. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Construction | 1770986 |
Electronic Plan | Original | / | 11/15/2022 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1770960 |
Floodplain | Original | N | 11/10/2022 | KEITH | KEITH | | | Floodplain | 1768877 |
Enumeration | Original | A | 11/10/2022 | BECKYA | BECKYA | Projected suites 100 and 110 are combining, this space will be using 110 as business address. | | Enumeration | 1768843 |
Electronic Plan | Original | / | 11/10/2022 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 1768826 |
Waste Water Div | Original | / | 11/9/2022 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 1768415 |
Water Division | Original | / | 11/9/2022 | SYSTEM | SYSTEM | You will need to contact Water Division department for approval prior to permit. This department will not review the plan electronically. | | Water Division | 1768414 |
Floodplain | Original | N | 11/9/2022 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5311101016) | | Floodplain | 1768413 |